Omni Instruments
contact icon+44 (0) 1382 443000
+44 (0) 845 9000 601
WE ARE HERE TO HELP

Contact our technical sales team now to discuss your requirements

help icon
MY BASKET basket arrow

£0.00

My Cart

You have no items in your shopping cart.

Click basket to edit.

Products

Latest added news blog
MSR175 Shock Transportation Data Logger
Kenny Laidlaw
Oct 01,2018
The MSR175 shock transportation data logger is the newest miniature logger from MSR.  The MSR175 ut...read more >
MX6 Replacement Sensor Cells
  • MX6 Replacement Sensor Cells

MX6 Replacement Sensor Cells

Quick Overview

The MX6 gas detectors include field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration. Up to 5 sensor can be installed, each in one or more specific location.

View Options

Details

Sensor Configuration

Up to five sensors can be installed, each in one or more specific locations. Installing a COSH (CO + H2S) sensor allows for a sensor configuration that provides gas readings for six gases. To support ingress protection, use a compatible plug in place of any uninstalled sensors.

In addition to the location restrictions for each sensor (below), these installation restrictions also apply:

  • Install only one infrared sensor.
  • Install only one COSH sensor.

 

MX6 Cell Placement

Part Number Gas Measurement Response Time  Location
Range Resolution T50 T90
17124975-3 Oxygen (O2) 0-30% Vol 0.10%Vol 6 Secs 15 Secs Any
17124975-K/L LEL (Catalytic) 0-100% LEL 1% LEL 15 Secs 35 Secs 5 Only
17124975-P LEL (Infrared) 0-100% LEL 1% LEL 15 Secs 35 Secs 4 or 5 Only
17124975-S Methane (CH4) (Infrared) 0-100% LEL 1% LEL 10 Secs 25 Secs 4 or 5 Only
17124975-M Methane (CH4) (Catalytic) 0-5% Vol 0.01% Vol 10 Secs 25 Secs 5 Only
17124975-6 Ammonia (NH3) 0 to 500ppm 1ppm 21 Secs 78 Secs Any
17124975-Q Carbon Dioxide (CO2) (Infrared) 0 to 5% Vol 0.01% Vol 10 Secs 25 Secs 4 or 5 Only
17124975-1 Carbon Monoxide (CO) 0 to 1,500ppm 1ppm 10 Secs 25 Secs Any
17124975-H Carbon Monoxide High (CO) 0 to 9,999ppm 1ppm 8 Secs 19 Secs Any
17124975-G Carbon Monoxide Hydrogen Low (CO/H2 Low) 0 to 1,000ppm 1ppm 9 Secs 20 Secs Any
17124975-J Carbon Monoxide/ 0 to 1,500ppm 1ppm 12 Secs 30 Secs Any
Hydrogen Sulphide (CO/H2S) 0 to 500ppm 0.1ppm 12 Secs 30 Secs
17124975-7 Chlorine (Cl2) 0 to 50ppm 0.1ppm 6 Secs 35 Secs Any
17124975-8 Chlorine Dioxide (ClO2) 0 to 1ppm 0.01ppm 7 Secs 60 Secs Any
17124975-C Hydrogen (H2) 0 to 2,000ppm 1ppm 25 Secs 65 Secs Any
17124975-A Hydrogen Chloride (HCl) 0 to 30ppm 0.1ppm 17 Secs 93 Secs Any
17124975-B Hydrogen Cyanide (HCn) 0 to 30ppm 0.1ppm 25 Secs 80 Secs Any
17124975-2 Hydrogen Sulphide (H2S) 0 to 500ppm 0.1ppm 7 Secs 20 Secs Any
17124975-4 Nitrogen Dioxide (NO2) 0 to 150ppm 0.1ppm 7 Secs 18 Secs Any
17124975-D Nitric Oxide 0 to 1,000ppm 1ppm 7 Secs 28 Secs Any
17124975-9 Phosphine 0 to 5ppm 0.01ppm 5 Secs 18 Secs Any
17124975-E Phosphine High 0 to 1,000ppm 1ppm 8 Secs 40 Secs Any
17124975-5 Sulphur Dioxide 0 to 150ppm 0.1ppm 5 Secs 20 Secs Any
17124975-R PID (Volatile Organic Compound VOC) 0 to 2,000ppm 0.1ppm 15 Secs 20 Secs 4 or 5 Only

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
Replacement Sensors
17124975-1
17124975-1
Replacement MX6 Sensor for Carbon Monoxide (CO). Range 0 to 1,500ppm, Resolution 1ppm.
£373.00
or call us for a quote
17124975-2
17124975-2
Replacement MX6 Sensor for Hydrogen Sulphide (H2S). Range 0 to 500ppm, Resolution 1ppm.
£373.00
or call us for a quote
17124975-3
17124975-3
Replacement MX6 Sensor for Oxygen (O2). Range 0 to 30% Volume, Resolution 0.1%Vol
£221.00
or call us for a quote
17124975-4
17124975-4
Replacement MX6 Sensor for Nitrogen Dioxide (NO2). Range 0 to 150ppm, Resolution 0.1ppm
£441.00
or call us for a quote
17124975-5
17124975-5
Replacement MX6 Sensor for Sulphur Dioxide (SO2). Range 0 to 150ppm, Resolution 0.1ppm
£441.00
or call us for a quote
17124975-6
17124975-6
Replacement MX6 Sensor for Ammonia (NH3). Range 0 to 500ppm, Resolution 1ppm
£556.00
or call us for a quote
17124975-7
17124975-7
Replacement MX6 Sensor for Chlorine (Cl2). Range 0 to 50ppm, Resolution 0.1ppm
£556.00
or call us for a quote
17124975-8
17124975-8
Replacement MX6 Sensor for Chlorine Dioxide (ClO2). Range 0 to 1ppm, Resolution 0.01ppm
£556.00
or call us for a quote
17124975-9
17124975-9
Replacement MX6 Sensor for Phosphine Low (PH3). Range 0 to 5ppm, Resolution 0.01ppm
£556.00
or call us for a quote
17124975-A
17124975-A
Replacement MX6 Sensor for Hydrogen Chloride (HCl). Range 0 to 30ppm, Resolution 0.1ppm.
£556.00
or call us for a quote
17124975-B
17124975-B
Replacement MX6 Sensor for Hydrogen Cyanide (HCN). Range 0 to 30ppm, Resolution 0.1ppm.
£556.00
or call us for a quote
17124975-C
17124975-C
Replacement MX6 Sensor for Hydrogen (H2). Range 0 to 2,000ppm, Resolution 1ppm.
£530.00
or call us for a quote
17124975-D
17124975-D
Replacement MX6 Sensor for Nitric Oxide (NO). Range 0 to 1,000ppm, Resolution 1ppm.
£556.00
or call us for a quote
17124975-E
17124975-E
Replacement MX6 Sensor for Phosphine High (PH3). Range 0 to 1,000ppm, Resolution 1ppm.
£556.00
or call us for a quote
17124975-G
17124975-G
Replacement MX6 Sensor for Carbon Monoxide/Hydrogen Null (CO/H2 null). Range 0 to 1,000ppm, Resolution 1ppm.
£482.00
or call us for a quote
17124975-H
17124975-H
Replacement MX6 Sensor for Carbon Monoxide High (CO High). Range 0 to 9,999ppm, Resolution 1ppm.
£373.00
or call us for a quote
17124975-J
17124975-J
Replacement MX6 Sensor for Combined Carbon Monoxide/Hydrogen Sulphide (CO/H2S). Range 0 to 1,500ppm (CO), Resolution 1ppm and 0 to 500ppm (H2S), Resolution 0.1ppm.
£504.00
or call us for a quote
17124975-K
17124975-K
Replacement MX6 Catalytic Sensor for Pentane (C5H12) Range 0 to 100%LEL, Resolution 1%LEL.
£295.00
or call us for a quote
17124975-L
17124975-L
Replacement MX6 Catalytic Sensor for Methane (CH4) Range 0 to 100%LEL, Resolution 1%LEL.
£295.00
or call us for a quote
17124975-M
17124975-M
Replacement MX6 Catalytic Sensor for Methane (CH4) Range 0 to 5% Volume, Resolution 0.01% Vol.
£295.00
or call us for a quote
17124975-P
Replacement MX6 Infrared Sensor for Hydrocarbons (Propane). Range 0 to 100% Volume, Resolution 1% Vol.
£634.00
or call us for a quote
17124975-Q
17124975-Q
Replacement MX6 Infrared Sensor for Carbon Dioxide (CO2). Range 0 to 5% Volume, Resolution 0.01% Vol.
£634.00
or call us for a quote
17124975-R
17124975-R
Replacement MX6 PhotoIonization Detector Sensor for Volatile Organic Compounds. Range 0-2,000 ppm, Resolution 0.1ppm.
View FilePID Response Factors
   Size: (431.44 KB)
£910.00
or call us for a quote
17124975-N
17124975-N
Replacement MX6 Infrared Sensor for Methane (CH4) Range 0 to 100% Volume, Resolution 1% Vol.
£634.00
or call us for a quote
17124975-S
Replacement MX6 Infrared Sensor for Methane (CH4). Range 0 to 100%LEL, Resolution 1%LEL.
£651.00
or call us for a quote