Omni Instruments
contact icon+44 (0) 1382 443000
+44 (0) 845 9000 601
WE ARE HERE TO HELP

Contact our technical sales team now to discuss your requirements

help icon
MY BASKET basket arrow

£0.00

My Cart

You have no items in your shopping cart.

Click basket to edit.

Products

Latest added news blog
MSR175 Shock Transportation Data Logger
Kenny Laidlaw
Oct 01,2018
The MSR175 shock transportation data logger is the newest miniature logger from MSR.  The MSR175 ut...read more >
9107A HART Transparent Driver
  • 9107A HART Transparent Driver

9107A HART Transparent Driver

Quick Overview

9107A is a 1- or 2-channel isolated 1:1 driver. The device allows for the operation and drive control of I/P converters, valves and indicators. Operation of HART devices is possible as the unit transmits HART communications signals bi-directionally. 9107A can be mounted in a safe area, or in Zone 2/Class I, Division 2, Groups A, B, C, or D.
View Options

Details

Application

  • 9107A is a 1- or 2-channel isolated 1:1 driver.
  • Operation and drive control of I/P converters, valves and indicators.
  • Operation of HART devices is possible as the unit transmits HART communication signals bi-directionally.
  • 9107A can be mounted in the safe area or in zone 2 / Class I, Division 2, Groups A, B, C, D.
  • The PR 45xx displays the process value for each channel and can be used to define high and low limits for detection of loop current level. If these limits are exceeded, the status relay will activate.
  • Dual channel versions can be used for signal splitter applications - 1 in and 2 out

Advanced features

  • The PR 45xx detachable display and the green and red front LEDs indicate operation status for each channel.
  • A tag number can be defined for each channel.
  • Output line fault detection.
  • In the 1-channel version the status relay can be used as a simple limit switch.
  • Suitable for the use in systems up to Performance Level “d” according to ISO-13849.

Technical characteristics

  • High galvanic isolation of 2.6 kVAC.
  • High accuracy better than 0.1%.
  • Continuous check of vital stored data for safety reasons.

Mounting

  • The devices can be mounted vertically or horizontally without distance between neighbouring units.

 

Environmental Conditions

Operating temperature -20°C to +60°C
Storage temperature -20°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20
Installation in Pollution degree 2 & measurement / overvoltage cat. II

 

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 104 mm
Dimensions (HxWxD) w/ 4501 / 4511 109 x 23.5 x 116 / 131 mm
Weight approx. 250 g
Weight incl. 4501 / 4511 (approx.) 265 g / 350 g
DIN rail type DIN EN 60715/35 mm
Wire size 0.13...2.08 mm2 AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm
Vibration IEC 60068-2-6 : 2007
Vibration: 2...13.2 Hz ±1 mm
Vibration: 13.2...100 Hz ±0.7 g

 

Common specifications

Supply

Supply voltage 19.2...31.2 VDC

Isolation voltage

Test /working: Input to any 2.6 kVAC / 300 VAC reinforced isolation
Analog output to supply 2.6 kVAC / 300 VAC reinforced isolation
Status relay to supply 1.5 kVAC / 150 VAC reinforced isolation

Response time

Response time (0...90%, 100...10%) < 5 ms
Programming via PR 4500 Series Interface/Displays
Signal dynamics, Input
Analog Signal Chain
Signal dynamics, Ouput Analog Signal Chain
HART bi-directional communication
frequency range
0.5...7.5 kHz
Signal / noise ratio > 60 dB
Accuracy Better than 0.1% of selected range
mA, absolute accuracy ≤ ±16 μA
mA, temperature coefficient ≤ ±1.6 μA / °C
Effect of supply voltage change on output
(nom. 24 VDC)
< ±10 μA
EMC immunity influence < ±0.5% of span
Extended EMC immunity: NAMUR NE 21,
A criterion, burst
< ±1% of span

 

Input specifications

Current input

Measurement range 3,5...23 mA
Sensor error detection: Loop break 4...20 mA < 1 mA
Input voltage drop, supplied unit < 2 V @ 23 mA
Input voltage drop, non-supplied unit < 4 V @ 23 mA

 

Output specifications

Current output

Signal range 3.5...23 mA
Load (@ current output) ≤ 725 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit ≤ 28 mA

Status relay

Max. voltage 110 VDC / 125 VAC
Max. current 0.3 ADC / 0.5 AAC
Status relay output terminal 33-34: Relay function N.C.
Programmable low setpoint 0...29.9 mA
Programmable high setpoint 0...29.9 mA
Hysteresis for setpoints 0.1 mA
Max. voltage - hazardous installation 32 VDC / 32 VAC
Max. current - hazardous installation 1 ADC / 0.5 AAC
of span = normal measurement range 4...20 mA

 

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
ATEX 2014/34/EU
RoHS 2011/65/EU
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011
EAC LVD TR-CU 004/2011

 

Approvals

ATEX DEKRA 11ATEX0247 X
FM FM16US0465X/FM16CA0213X
UL UL 61010-1 E314307
UL 913 E233311 (only 9107xx-U9)
CCC 2020322304003422
EAC Ex
RU C-DK.HA65.B.00355/19
DNV Marine TAA00000JD
ClassNK TA18527M
SIL SIL 2 certified & fully assessed acc. to IEC 61508

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
PR 9107A Transparent HART Driver
9107AA
9107AA

PR 9107AA Single Channel HART Transparent Driver. Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus ATEX, IECEx, FM, INMETRO, CCC and EAC-Ex Approvals. Power Supply: 19.2-31.2vDC, via power rail or terminals. DIN Rail Mounted. Dimensions: 109 x 23.5 x 104mm. Operating Temperature: -20 to +60°C, 0-95%RH (Non-condensing).

£222.61
or call us for a quote
9107AB
9107AB

PR 9107AB Dual Channel HART Transparent Driver. Signal Splitter (1 In, 2 Out), or Dual Channels, Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus ATEX, IECEx, FM, INMETRO, CCC and EAC-Ex Approvals. Power Supply: 19.2-31.2vDC, via power rail or terminals. DIN Rail Mounted. Dimensions: 109 x 23.5 x 104mm. Operating Temperature: -20 to +60°C, 0-95%RH (Non-condensing).

£305.96
or call us for a quote
 
PR 9107A Transparent HART Driver with U913 Approvals
9107AA-U9
9107AA-U9

PR 9107AA-U9 Single Channel HART Transparent Driver. Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus UL913, ATEX, IECEx, FM, INMETRO, CCC and EAC-Ex Approvals. Power Supply: 19.2-31.2vDC, via power rail or terminals. DIN Rail Mounted. Dimensions: 109 x 23.5 x 104mm. Operating Temperature: -20 to +60°C, 0-95%RH (Non-condensing).

£228.94
or call us for a quote
9107AB-U9
9107AB-U9

PR 9107AB-U9 Dual Channel HART Transparent Driver. Signal Splitter (1 In, 2 Out), or Dual Channels, Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus UL913 ATEX, IECEx, FM, INMETRO, CCC and EAC-Ex Approvals. Power Supply: 19.2-31.2vDC, via power rail or terminals. DIN Rail Mounted. Dimensions: 109 x 23.5 x 104mm. Operating Temperature: -20 to +60°C, 0-95%RH (Non-condensing).

£310.18
or call us for a quote
 
Detachable Keypad / Display / Programmer
4510
4510

4510 Programming display for systems 4000 and 9000 devices. Each 4510 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status. The 4510 display clicks onto the front of the units are is interchangeable between units for programming or display.

View FileDatasheet
   Size: (647.78 KB)
£68.57
or call us for a quote
 
Detachable Communication Interfaces
4511
4511
4511 Programming display and Modbus RTU protocol interface for systems 4000 and 9000 devices. Each 4511 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as an RS485 Modbus RTU connection to a local network. The 4511 display clicks onto the front of the device and an RJ45 connector on top of the unit allows for connection to a Modbus network.
View FileDatasheet
   Size: (311.08 KB)
£92.85
or call us for a quote
 
Bluetooth Communication Interface
4512
4512
4512 Bluetooth Communications Interface. Allows for programming and live readings to a iOS or Android device and any of the 4000 and 9000 Series devices. Each 4512 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as the 4512 can also provide 30 days data logging at 1 second intervals of the connected devices. The 4512 display clicks onto the front of the device and can be connected to a 4590 to allow for a direct connection to a PC to allow for direct configuration, collecting logged data and event logs.
View FileDatasheet
   Size: (353.05 KB)
£92.85
or call us for a quote