For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
REF | DESCRIPTION | DOWNLOADS | PRICE | ORDER ITEM |
---|---|---|---|---|
Tinytag Plus 2 Data Loggers | ||||
TGP-4703 |
Tinytag Plus 2 Voltage data logger. Range 0-2.5vDC. Memory for 32,000 readings with 2 programmable alarms. Logging rate 1 sec to 10 days with min, max & actual readings, battery life up to 2 year. Splash proof I.P. 65 case. Unit is supplied with the Current/Voltage input cable, CAB-3239 | Datasheet Size: (255.44 KB) |
£125.00 |
or call us for a quote
|
TGP-4704 |
Tinytag Plus 2 Voltage data logger. Range 0-25vDC. Memory for 32,000 readings with 2 programmable alarms. Logging rate 1 sec to 10 days with min, max & actual readings, battery life up to 2 year. Splash proof I.P. 65 case. Unit is supplied with the Current/Voltage input cable, CAB-3239 | Datasheet Size: (255.44 KB) |
£125.00 |
or call us for a quote
|
TGP-4804 |
Tinytag Plus 2 Current data logger. Range 0-25mA. Memory for 32,000 readings with 2 programmable alarms. Logging rate 1 sec to 10 days with min, max & actual readings, battery life up to 2 year. Splash proof I.P. 65 case. Unit is supplied with the Current/Voltage input cable, CAB-3239 | Datasheet Size: (255.44 KB) |
£125.00 |
or call us for a quote
|
TGP-4703-ED |
Tinytag Plus 2 Voltage data logger. Range 0-2.5vDC. Memory for 32,000 readings with 2 programmable alarms. Logging rate 1 sec to 10 days with min, max & actual readings, battery life up to 2 year. Splash proof I.P. 65 case. Unit is supplied with the Current/Voltage input cable, CAB-3239. Custom Scaling to show readings in required units, ie. Bar, m/s, etc. |
Tinytag Instrumentation Scaling Form Size: (955.19 KB) |
£175.00 |
or call us for a quote
|
TGP-4704-ED |
Tinytag Plus 2 Voltage data logger. Range 0-25vDC. Memory for 32,000 readings with 2 programmable alarms. Logging rate 1 sec to 10 days with min, max & actual readings, battery life up to 2 year. Splash proof I.P. 65 case. Unit is supplied with the Current/Voltage input cable, CAB-3239. Custom Scaling to show readings in required units, ie. Bar, m/s, etc. |
Tinytag Instrumentation Scaling Form Size: (955.19 KB) |
£175.00 |
or call us for a quote
|
TGP-4804-ED |
Tinytag Plus 2 Current data logger. Range 0-25mA. Memory for 32,000 readings with 2 programmable alarms. Logging rate 1 sec to 10 days with min, max & actual readings, battery life up to 2 year. Splash proof I.P. 65 case. Unit is supplied with the Current/Voltage input cable, CAB-3239. Custom Scaling to show readings in required units, ie. Bar, m/s, etc. |
Tinytag Instrumentation Scaling Form Size: (955.19 KB) |
£175.00 |
or call us for a quote
|
Tinytag Input Lead | ||||
CAB-3239 |
Tinytag CAB-3249 Voltage/Current Input Lead for connection of voltage and current input signals to Tinytag data loggers. Includes a 5-pin connection to logger and 1m flying tails. | Datasheet Size: (430.71 KB) |
£20.00 |
or call us for a quote
|
Tinytag Connector | ||||
ACS-9703 |
A 5-pin plug which can be used to connect your own cable for Tinytag voltage and current data loggers. It can also be used to connect your own PT100/PT1000 probe/sensor with suitable Tinytag loggers. | £25.00 |
or call us for a quote
|
|
Accessories | ||||
ACS-6000 |
Trigger Start Magnet for various Tinytag data loggers. The magnet is ideal for delayed triggering of Tinytag loggers that have been set up for a trigger start. The magnet is merely passed over the correct location on the logger and the lights will start to flash showing that logging procedure has been started. The position of the unit’s trigger start switch is indicated by the • • • label on the back of the logger. | £10.00 |
or call us for a quote
|
|
Tinytag Starter Packs | ||||
SWPK-7-USB |
Tinytag software and download cable starter pack. This starter pack contains a USB download cable, Software CD, with device drivers and a quick start guide. This pack is suitable for use with the all Tinytag Ultra, Plus and View data loggers. The Tinytag software comes with a site licence allowing installation on multiple PCs at the same location, additional software should be purchased when used at a different site location. | £65.00 |
or call us for a quote
|
|
Tinytag Download Cables | ||||
CAB-0007-USB |
Tinytag Ultra/Plus/View USB Download Cable. Suitable for all Tinytag Ultra, Plus and View data loggers. Cable length 1m. | Datasheet Size: (430.71 KB) |
£25.00 |
or call us for a quote
|
Tinytag Service Kits | ||||
SER-9500 |
The SER-9500 service kit is suitable for the Tinytag Ultra 2, Talk 2, TinyTalk, View 2, Plus 2, Plus and IS data loggers. This kit contains a replacement battery, gasket, lanyard, cable tie, desiccant pack and a service instruction sheet. | Tinytag Service Kit Instruction Sheet Size: (68.43 KB) |
£6.50 |
or call us for a quote
|
Tinytag Plus 2 Data Loggers | ||||
ED-0001 |
Custom scaling of Tinytag Plus 2 and View 2 Instrumentation Data Loggers for third party sensors. Price per logger. Returned loggers only, please order parts ending -ED for new loggers. | Tinytag Instrumentation Scaling Form Size: (955.19 KB) |
£70.00 |
or call us for a quote
|