For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
REF | DESCRIPTION | DOWNLOADS | PRICE | ORDER ITEM |
---|---|---|---|---|
PR 3103 Isolated Repeater | ||||
3103 |
3103 Slim Series Isolated Repeater suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of current signals within the range 0-20 mA, Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via power rail or terminals. 6mm Slimline housing. | Datasheet Size: (458.16 KB) |
£130.82 |
or call us for a quote
|
3103-N |
3103 Slim Series Isolated Repeater suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of current signals within the range 0-20 mA, Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing. | £130.82 |
or call us for a quote
|
|
PR 3104 Isolated Converter | ||||
3104 |
3104 Slim Series Isolated Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of 0/2-10V, 0/1-5V and 0/4-20mA input signals to 0/2-10V, 0/1-5V and 0/4-20mA output signals. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via power rail or terminals. 6mm Slimline housing. Units are DIP-switch configured. | Datasheet Size: (507.22 KB) |
£146.65 |
or call us for a quote
|
3104-N |
3104 Slim Series Isolated Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of 0/2-10V, 0/1-5V and 0/4-20mA input signals to 0/2-10V, 0/1-5V and 0/4-20mA output signals. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing. Units are DIP-switch configured. | £146.65 |
or call us for a quote
|
|
PR 3105 Isolated Converter | ||||
3105 |
3105 Slim Series Isolated Converter suitable for use in Safe Areas. Isolation and conversion of 0/2-10V, 0/1-5V and 0/4-20mA input signals to 0/2-10V, 0/1-5V and 0/4-20mA output signals. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via power rail or terminals. 6mm Slimline housing. Units are DIP-switch configured. | Datasheet Size: (459.87 KB) |
£128.71 |
or call us for a quote
|
3105-N |
3105 Slim Series Isolated Converter suitable for use in Safe Areas. Isolation and conversion of 0/2-10V, 0/1-5V and 0/4-20mA input signals to 0/2-10V, 0/1-5V and 0/4-20mA output signals. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing. Units are DIP-switch configured. | £128.71 |
or call us for a quote
|
|
PR 3114 Isolated Universal Converters | ||||
3114 |
3114 Slim Series Isolated Universal Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of 0-20mA, 0-10vDC, Thermocouple, PT100, RTD, Potentiometer input signals to 0-10V or 0-20mA output signals. Response time: less than 400ms (1s for Temp Inputs), Accuracy 0.1% of span. Power Supply: 24vDC +/-30%, supplied with power rail connector. 6mm Slimline housing. Units are Programmable via 4501 display and 4590 adapter. | Datasheet Size: (433.24 KB) |
£176.19 |
or call us for a quote
|
3114-N |
3114 Slim Series Isolated Universal Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of 0-20mA, 0-10vDC, Thermocouple, PT100, RTD, Potentiometer input signals to 0-10V or 0-20mA output signals. Response time: less than 400ms (1s for Temp Inputs), Accuracy 0.1% of span. Power Supply: 24vDC +/-30%, via terminals only. 6mm Slimline housing. Units are Programmable via 4501 display and 4590 adapter. | £176.19 |
or call us for a quote
|
|
PR 3108 Isolated Repeater/Splitter | ||||
3108 |
3108 Slim Series Isolated Repeater/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of current signals within the range 0-20 mA. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC +/-30%. 6mm Slimline housing. | Datasheet Size: (455.84 KB) |
£156.14 |
or call us for a quote
|
3108-N |
3108 Slim Series Isolated Repeater/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of current signals within the range 0-20 mA. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC +/-30%, via terminals only. 6mm Slimline housing. | £156.14 |
or call us for a quote
|
|
PR 3109 Isolated Converter/Splitter | ||||
3109 |
3109 Slim Series Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of a single 0/2-10V, 0/1-5V and 0/4-20mA input signal to individually configurable 0/2-10V, 0/1-5V and 0/4-20mA on two output channels. The 3109 can also provide power supply and signal isolation to a 2 wire transmitter with a mA output. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via power rail or terminals. 6mm Slimline housing. Units are DIP-switch configured. | Datasheet Size: (525.34 KB) |
£175.13 |
or call us for a quote
|
3109-N |
3109 Slim Series Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of a single 0/2-10V, 0/1-5V and 0/4-20mA input signal to individually configurable 0/2-10V, 0/1-5V and 0/4-20mA on two output channels. The 3109 can also provide power supply and signal isolation to a 2 wire transmitter with a mA output. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing. Units are DIP-switch configured. | £175.13 |
or call us for a quote
|
|
PR 3117 Bipolar Isolated Converter | ||||
3117 |
3117 Slim Series Bipolar Isolated Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of bipolar inputs to unipolar outputs. Input options of 10mA, 20 mA, 5V or 10V with unipolar mA or V outputs. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC +/-30%. 6mm Slimline housing. Units are DIP-switch configured. | Datasheet Size: (577.39 KB) |
£147.71 |
or call us for a quote
|
3117-N |
3117 Slim Series Bipolar Isolated Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of bipolar inputs to unipolar outputs. Input options of ±10mA, ±20 mA, ±5V or ±10V with unipolar mA or V outputs. Response time: less than 7 ms, Accuracy ±0.05% of span. Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing. Units are DIP-switch configured. | £147.71 |
or call us for a quote
|
|
PR 3118 Bipolar Isolated Converter/Splitter | ||||
3118 |
3118 Slim Series Bipolar Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of bipolar inputs to up to 2 unipolar or 1 bipolar outputs. Input options of 10mA, 20 mA, 5V or 10V with two individually configurable unipolar 0/2-10V, 0/1-5V and 0/4-20mA outputs or a single bipolar 10mA or 20 mA output . Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC +/-30%. 6mm Slimline housing. Units are DIP-switch configured. | Datasheet Size: (635.46 KB) |
£180.40 |
or call us for a quote
|
3118-N |
3118 Slim Series Bipolar Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of bipolar inputs to up to 2 unipolar or 1 bipolar outputs. Input options of ±10mA, ±20 mA, ±5V or ±10V with two individually configurable unipolar 0/2-10V, 0/1-5V and 0/4-20mA outputs or a single bipolar ±10mA or ±20 mA output . Response time: less than 7 ms, Accuracy ±0.05% of span. Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing. Units are DIP-switch configured. | £180.40 |
or call us for a quote
|
|
PR 3185A Loop-Powered Isolator | ||||
3185A1 |
3185 Slim Series Single Channel Loop Powered Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of current signals within the range 0-20mA, Response time: less than 7 ms, Accuracy 0.1% of span. Power Supply: Loop powered via the input loop, voltage drop 1.2V with a 10uA start up current. 6mm Slimline housing. | Datasheet Size: (563.21 KB) |
£92.85 |
or call us for a quote
|
3185A2 |
3185 Slim Series Dual Channel Loop Powered Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of current signals within the range 0-20mA, Response time: less than 7 ms, Accuracy 0.1% of span. Power Supply: Loop powered via the input loop, voltage drop 1.2V with a 10uA start up current. 6mm Slimline housing. | £131.88 |
or call us for a quote
|
|
Slim Series Power Control Units | ||||
3405 |
The 3405 Power Connector Unit is an ATEX approved power supply for use with the 9400 Power Rail. The Power Connector can supply up to 100 units and supply up to 2.5A. The Power Connector can be used to provide power to the Power Rail from the supply terminals, or to supply power via the supply terminals from the Power Rail. Unit can be mounted in an ATEX Zone 2 environment. | Data Sheet Size: (328.36 KB) |
£71.74 |
or call us for a quote
|
9410 |
The 9410 Power Connector Unit distributes a 24vDC supply voltage to the 9400 Power Rail. The Power Connector can supply up to 200 units and supply up to 4A. The unit has the option of a secondary back-up power supply to ensure supply and is suitable for use in a ATEX Zone 2 environment. | Data Sheet Size: (558.97 KB) |
£163.53 |
or call us for a quote
|
Power Rail & Accessories | ||||
9400A |
9400 Power Rail distributes power to mounted 3100 Slim Series isolators. The Power Rail is supplied with cover and 2 end covers (1 right-hand and 1 left-hand). Dimensions: 35 x 15mm (W x D). Supplied in 1m (±2mm) lengths and can be cut to size and fitted with additional end covers. | £98.11 |
or call us for a quote
|
|
9402 |
Additonal end covers for 9400 Power Rail. Kit includes a pair of end covers for a 9400 Power Rail. | £4.22 |
or call us for a quote
|
|
9404 |
Module Stop for 9400 Power Rail. Provides support and secure mounted devices to power rail. | £6.33 |
or call us for a quote
|
|
Detachable Keypad / Display / Programmer | ||||
4510 |
4510 Programming display for systems 4000 and 9000 devices. Each 4510 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status. The 4510 display clicks onto the front of the units are is interchangeable between units for programming or display. |
Datasheet Size: (647.78 KB) |
£69.00 |
or call us for a quote
|
PR 4590 ConfigMate | ||||
4590 |
4590 ConfigMate handheld device. Handheld adaptor to provide an interface between the 4510 keypad/display and 3100 slim series units. Allows configuration and monitoring of process parameters via the 4510 programming display. | £155.10 |
or call us for a quote
|
|
PR Custom Configuration | ||||
PR-CONFIG |
Complete programming and configuration of programmable PR units to client specifications prior to shipping. | £19.00 |
or call us for a quote
|