- 1, 4 or 8 channel panel mounted data logger
- Fixed inputs RTD or thermcouple temperature inputs, 20mA or 10V inputs
- 2 relay outputs
- USB host port for flash data storage and configuration transfer
- RS485/Modbus RTU
- Memory for up to 3 million readings
- Free configuration and recording software (Loggy Soft and S-Toolkit).
The device has the memory capacity of 8 MB (3 million data recordings altogether). However when a USB flash drive is plugged permanently, it can significantly extend the recording time without a need of data transferring from SRD-99 to a PC. The logging rate is programmable from 1 second to 60 minutes.
The Loggy Soft program enables the visualization, archiving and printing of measurements (e.g. temperature, humidity, pressure) stored in the MultiLog device memory.
The S-Toolkit software enables configuration reading and writing operations, updating the device firmware and obtaining basic information on the MultiLog series devices through RS-485 serial interface or flash-disk devices plugged into USB port.
Power Supply Voltage: | 19V ÷ 50V DC or 16V ÷ 35V AC 85 ÷ 260V AC/DC |
Power Consumption: | 3 VA typical; 5 VA Max. |
Display: | Graphic LCD, 128 x 64 points, with backlight (SRD-99A: Amber or SRD-99W: White) |
Measuring Inputs: | Current: 0-20mA or 4-20mA Voltage: 0/1-5V or 0/2-10V RTD: PT100, PT500 or PT1000 Thermocouple: Types K, J, N, S, T, R, B or E. |
Measuring Range: | Analogue (current or voltage): ± 9999 + decimal point, resolution >1mV RTD: -100.0°C +600.0°C with resolution 0,1°C; -148°F +999,9°F with resolution 0,1°F Thermocouple: -200°C ÷ +1370°C (K); -50°C ÷ +1768°C (S); -210°C ÷ +1200°C (J); -200°C ÷ +400°C (T); -200°C ÷ +1300°C (N); -50°C ÷ +1768°C (R); +250°C ÷ +1820°C (B); -200°C ÷ +1000°C (E) |
Sample Rate: | 1s, 2s, 5s, 10s, 15s, 20s, 30s, 1 min, 2 min, 5 min, 10 min, 15 min, 20 min, 30 min, 60 min. |
Logging Modes | Stop when full or memory wrap |
Digital Input: | 1 input 24V DC, used to control logging function |
Relay Outputs: | 2 Relays (R1, R2) Max 250vAC (30vDC) @ 1A. |
Sensors Supply: | 24vDC±5% / 200 mA (only analogue version, not separated from measuring inputs |
Communication Interface: | RS-485 (MODBUS RTU), USB PC or USB Host port, galvanically isolated |
Transmission Speed: | 1200 – 115200 bit/sec. |
Memory Capacity: | 8 MB (up to 3 million data records). May be expanded using USB Host and memory stick. |
IP Rating: | IP65 |
Working Temperature: | 0°C to +50°C, -20 to +50°C option. |
Storage Temperature: | -10°C to +70°C, -20°C with option. |
Case Dimensions: | 166 x 161 x 103mm, 1665 x 191 x 103mm with glands |
Glands: | 1 channel: 2 x M20 (multi hole inserts 2 x 5 mm), 1 x M16 4 channels: 3 x M20 (multi hole inserts 2 x 5 mm), 1 x M16 8 channels: 2 x M25 (multi hole inserts 4 x 5 mm), 1 x M20 (multi hole inserts 2 x 5 mm), 1 x M16 |