Column Type Compression Dome Top Load Cell
  • Column Type Compression Dome Top Load Cell

CCDDT Column Type Compression Dome Top Load Cell

6-8 Weeks

Quick Overview

The CCDDT load cells are dome top column load cells designed for the measurement of compressive forces. The CCDDT can be used for applications including hydraulic press calibration, pile force measurement, jack force measurement, centre of gravity measurement systems and structural proof testing. Ranges 2 to 1,000 tonnes. Standard output is 1.5mV/V with an accuracy of ±0.25% and options for inline amplifiers for standard 4-20mA or voltage outputs.
View Options

Details

The CCDDT dome top column load cell is designed to be used for compression load measurements in general use applications or in permanent outdoor installations. The CCDDT series load cells feature a dome top to minimise the effects of offset loads. Load caps are available to provide a fall surface, if required.  The load cells stainless steel construction and IP67 dust tight and optional IP68 immersion protection it is suitable for harsh environments.

Special versions can be manufactured to fit applications where the standard model is not quite suitable. The load cell design can be readily modified to provide higher integrity where environmental conditions are particularly arduous such as in marine and offshore applications, including IP68 fully submersible versions. It is also possible to manufacture low-height versions if space is at a premium.

Features

  • Capacities 2 tonne up to 1,000 tonne
  • Output 1.5mV/V
  • Sealed to IP67
  • Robust Stainless Steel Construction
  • Carry handles for load cells over 200T capacities
  • Can be supplied with loading cap & mounting base
  • Optional amplifier output & integral connector
  • 3 Year warranty

Options

  • Full Range of Mounting Options Available, including Custom/Standard Loading Caps and Custom Mounting Bases
  • Special Sizes, or Ranges Available on Request.
  • Fully Submersible versions rated to IP68 are available
  • Versions available with integral signal amplifiers.
  • External Inline Signal Amplifiers.
  • Shunt calibration
  • TEDS Available for Plug & Play with TEDS Enabled Instrumentation
  • Vacuum Application Version
  • High Accuracy Version
  • Wireless Version (using T24 Instrumentation)

Applications

  • Hydraulic Press Calibration
  • Pile Force Measurement
  • Jack Force Measurement
  • Centre of Gravity Measurement Systems
  • Structural Proof Testing
  • High Capacity Multi-Point Weighing Systems
  • Silo Weighing

Specifications

Standard Capacities (Tonnes): 0-2, 0-5, 0-10, 0-25, 0-50, 0-100, 0-200, 0-300, 0-500, 0-750, 0-1000
Sensitivity: 1.5mv/V Nominal
Zero Balance/Offset: <±1.0% Rated Output
Non-Linearity: <±0.25% Rated Output
Hysteresis: <±0.25% Rated Output
Repeatability: <±0.05% Rated Output
Bridge Resistance: 700 Ohms (2-50 Tonnes), 1400 (100-1,000 Tonnes) Nominal
Insulation Resistance: >500 Megaohms @ 500vDC
Excitation Voltage: 10vDC Recommended (2-15vDC Acceptable)
Operating Temperature: -20 to +70°C
Compensated Temperature: -10 to +50°C
Storage Temperature: -20 to +70°C
Safe Overload: 150% of Rated Capacity
Ultimate Overload: 300% of Rated Capacity
IP Rating: Standard IP67, IP68 available on request
Fatigue Life: 108 Cycles Typical (109 cycles on fatigue-rated version)
Cable: 5m, 4-Core Screened, PUR Sheath
Construction: Stainless Steel

Dimensions

CCDDT Dimensional Drawings

Capacity Loadcell Load Cap Mounting Base
H ØD T S ØB Weight H1 H2 ØD1 R ØB ØC H3 ØM ØP ØQ U
0-2 Tonnes 41 31 M3 5 20 1Kg 10 8 31 30 20 40 10 50 3.2 6 4
0-5 Tonnes 41 31 M3 5 20 1Kg 10 8 31 30 20 40 10 50 3.2 6 4
0-10 Tonnes 75 50 M4 8 34 2.5Kg 15 13 60 76 34 64 10 80 4.5 10 6
0-25 Tonnes 75 50 M4 8 34 2.5Kg 15 13 60 76 34 64 10 80 1.5 10 6
0-50 Tonnes 103 88 M4 10 50 .6.5Kg 20 16 88 159 50 100 10 120 4.5 10 6
0-100 Tonnes 153 100 M5 12 70 11Kg 30 28 101 151 70 120 10 140 5.5 11 7
0-200 Tonnes 180 125 n/a n/a 78 19Kg 40 29 125 102 n/a n/a n/a n/a n/a n/a n/a
0-300 Tonnes 185 138 n/a n/a n/a 21Kg 45 38 165 182 n/a n/a n/a n/a n/a n/a n/a
0-500 Tonnes 250 165 n/a n/a n/a 42Kg 50 40 165 260 n/a n/a n/a n/a n/a n/a n/a
0-750 Tonnes 350 198 n/a n/a n/a 85Kg 80 70 198 360 n/a n/a n/a n/a n/a n/a n/a
0-1000 Tonnes 400 276 n/a n/a n/a 220Kg 80 70 276 410 n/a n/a n/a n/a n/a n/a n/a

The optional load cap and mounting base help to ease installation and provide optimal performance from the load cell.

Availability: In stock

Price range : £786.00 - £2,205.00

Price as configured: £0.00

* Required Fields

Price as configured: £0.00

 

Part Builder

Description       CCDDT Column Type Compression Dome Top Load Cell.
 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
CCDDT Column Compression Load Cell
CCDDT Load Cell
CCDDT Load Cell
CCDDT Column Compression Load Cell. Ranges 2 Tonnes to 1000 Tonnes. Output 2mV/V, accuracy available to
View FileDatasheet - Load Cell
   Size: (500.16 KB)
£786.00

Not Available online

 
Load Caps for CCDDT Load Cells
CCDDT-2T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 2 Tonnes. Dimensions: Diameter 31mm, Height 10mm, Internal Radius 30mm
£103.50
or call us for a quote
CCDDT-5T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 5 Tonnes. Dimensions: Diameter 31mm, Height 10mm, Internal Radius 30mm
£103.50
or call us for a quote
CCDDT-10T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 10 Tonnes. Dimensions: Diameter 60mm, Height 15mm, Internal Radius 76mm
£132.50
or call us for a quote
CCDDT-25T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 25 Tonnes. Dimensions: Diameter 60mm, Height 15mm, Internal Radius 76mm
£132.50
or call us for a quote
CCDDT-50T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 50 Tonnes. Dimensions: Diameter 88mm, Height 20mm, Internal Radius 159mm
£145.00
or call us for a quote
CCDDT-100T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 100 Tonnes. Dimensions: Diameter 101mm, Height 30mm, Internal Radius 151mm
£165.00
or call us for a quote
CCDDT-200T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 200 Tonnes. Dimensions: Diameter 125mm, Height 40mm, Internal Radius 102mm
£218.00
or call us for a quote
CCDDT-300T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 300 Tonnes. Dimensions: Diameter 165mm, Height 45mm, Internal Radius 182mm
£234.50
or call us for a quote
 
TRX Handheld Portable Load Cell Indicator
TRX
TRX
Microprocessor-Based Portable Handheld Display for All Types of Strain Gauge Sensors. 2 x AA Battery, or USB Powered with Sensitivity Ranges from 0.5mV/V up to ±480mV/V. The TRX option to use the TRX calibration ranges, or to ignore the TEDS data and us manually entered sensitivity ranges. 128 x 64 monochrome dot matrix display with backlight. The display will change depending on the mode and options you have enabled.
View FileDatasheet
   Size: (489.18 KB)
£354.00
or call us for a quote
 
TR150 Handheld Portable Load Cell Indicator
TR150
TR150
Handheld Portable Load Cell Indicator. The TR150 is a high resolution digital load cell meter designed to work with all types of load cell and strain gauge based transducer. 7-digit LCD display, peak & trough capture, display update rates up to 25Hz, display hold/freeze and shunt calibration. Load Cell Display is housed in a robust IP65 enclosure with 2 x AA batteries to provide up to 450 hours operation.
View FileDatasheet
   Size: (268.49 KB)
View FileOperating Manual
   Size: (562.15 KB)
£282.00
or call us for a quote
 
TR150 Protective Case
TR150-CASE
TR150-CASE
Protective Black Leather Case for TR150 handheld display. The TR150 leather carry case allows full operation of the indicator whilst fitted.
£32.00
or call us for a quote
 
TR150 Connector
TR150-CONNECTOR
Connector for the TR150 Handheld Display.
£30.00
or call us for a quote
 
DSC-USB Load Cell Digitiser Module
DSC-USB
DSC-USB

DSC-USB Load Cell Digitiser Module. The DSC-USB is a USB load cell interface designed to convert load cell inputs into a digital USB Serial output, 100 samples per second. It is housed in a rugged plastic enclosure (71 x 51 x 20mm) rated to IP50 with a D9 connector and female micro USB connector. The DSC-USB draws power directly from the PC interface and units are supplied with DSCUSB to USB converter tool kit software and USB to micro USB cable, 1.5m.

View FileDatasheet
   Size: (599.99 KB)
£290.00
or call us for a quote