Contact our technical sales team now to discuss your requirements
£0.00
You have no items in your shopping cart.
Click basket to edit.
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
REF | DESCRIPTION | DOWNLOADS | PRICE | ORDER ITEM |
---|---|---|---|---|
Tinytag Radio Units for Thermistor Probes | ||||
TGRF-4021-A |
Tinytag Plus Radio Temperature Data Logger for One External Thermistor Probe. Measurement Range: -40 to +125°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation. |
Datasheet Size: (1.08 MB) |
£285.00 |
or call us for a quote
|
TGRF-4022-A |
Tinytag Plus Radio Temperature Data Logger for Two External Thermistor Probe. Measurement Range: -40 to +125°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation. |
£320.00 |
or call us for a quote
|
|
TGRF-4024-A |
Tinytag Plus Radio Temperature Data Logger for Four External Thermistor Probe. Measurement Range: -40 to +125°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation. |
£345.00 |
or call us for a quote
|
|
Tinytag Radio Units for PT100 Probes | ||||
TGRF-4101-A |
Tinytag Plus Radio Temperature Data Logger for One External PT100 Temperature Probe. Measurement Range: -50 to +600°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation. |
£290.00 |
or call us for a quote
|
|
TGRF-4102-A |
Tinytag Plus Radio Temperature Data Logger for Two External PT100 Temperature Probe. Measurement Range: -50 to +600°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation. |
£325.00 |
or call us for a quote
|
|
Tinytag Radio Units for PT1000 Probes | ||||
TGRF-4202-A |
Tinytag Plus Radio Temperature Data Logger for Two External PT1000 Temperature Probe. Measurement Range: -200 to +100°C, Resolution 0.01°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation. |
£325.00 |
or call us for a quote
|
|
TGRF-4201-A |
Tinytag Plus Radio Temperature Data Logger for One External PT1000 Temperature Probe. Measurement Range: -200 to +100°C, Resolution 0.01°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation. | £290.00 |
or call us for a quote
|
|
Tinytag Radio Units with a Temperature & Humidity probe | ||||
TGRF-4600-A |
Tinytag Plus Radio Temperature Data Logger with One Temperature and Relative Humidity Probe. Measurement Range: -25 to +85°C, Resolution 0.01°C and 0.04%RH. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation, PBRF-8002 Probe, CAB-0034 Cable and a Probe Mounting Clip. |
Datasheet Size: (301.14 KB) |
£380.00 |
or call us for a quote
|
TGRF-4602-A |
Tinytag Plus Radio Temperature Data Logger with Two Temperature and Relative Humidity Probes. Measurement Range: -25 to +85°C, Resolution 0.01°C and 0.04%RH. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation, Two PBRF-8002 Probes, Two CAB-0034 Cables and Two Probe Mounting Clips. |
£465.00 |
or call us for a quote
|
|
Tinytag Radio Units for Voltage Inputs | ||||
TGRF-4703-A |
Tinytag Plus Radio Data Logger for One 2.5V Voltage Input. Measurement Range: 0 to 2.5V, Resolution 100µV. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and One CAB-3239 (Tinytag Voltage Input Lead). |
£290.00 |
or call us for a quote
|
|
TGRF-4743-A |
Tinytag Plus Radio Data Logger for Four 2.5V Voltage Inputs. Measurement Range: 0 to 2.5V, Resolution 100µV. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and Four CAB-3239's (Tinytag Voltage Input Leads). |
£350.00 |
or call us for a quote
|
|
TGRF-4704-A |
Tinytag Plus Radio Data Logger for One 25V Voltage Input. Measurement Range: 0 to 25V, Resolution 1mV. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, One CAB-3239 (Tinytag Voltage Input Lead). |
£290.00 |
or call us for a quote
|
|
TGRF-4744-A |
Tinytag Plus Radio Data Logger for Four 25V Voltage Inputs. Measurement Range: 0 to 25V, Resolution 1m;V. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and Four CAB-3239's (Tinytag Voltage Input Leads). |
£350.00 |
or call us for a quote
|
|
Tinytag Radio Units for Current Inputs | ||||
TGRF-4804-A |
Tinytag Plus Radio Data Logger for One 20mA Current Input. Measurement Range: 0 to 20mA, Resolution 1µA. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and a CAB-3246 (Tinytag Current/Millivolt.Count Input Lead). |
£290.00 |
or call us for a quote
|
|
Tinytag Radio Units for Pulse Counts | ||||
TGRF-4901-A |
Tinytag Plus Radio Data Logger for One Pulse Count Input. Measurement Range: 0 to 32,737 Counts per Interval, Max Frequency 250 Counts/Second. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and a CAB-3246 (Tinytag Current/Millivolt.Count Input Lead). |
£290.00 |
or call us for a quote
|
|
TGRF-4904-A |
Tinytag Plus Radio Data Logger for Four Pulse Count Input. Measurement Range: 0 to 32,737 Counts per Interval, Max Frequency 250 Counts/Second. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and a CAB-3246 (Tinytag Current/Millivolt.Count Input Lead). |
£350.00 |
or call us for a quote
|
|
Tinytag Radio Receiver Units | ||||
ACSRF-4030-PK-A |
Tinytag Radio Receiver Unit complete with software, USB cable. Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the USB port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g, | £805.00 |
or call us for a quote
|
|
ACSRF-4040-PK-A |
Tinytag Radio Receiver Unit complete with software, Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the RJ45 port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g, | £805.00 |
or call us for a quote
|
|
ACSRF-4030-A |
Tinytag Radio Receiver Unit only. Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the USB port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g, | £500.00 |
or call us for a quote
|
|
ACSRF-4040-A |
Tinytag Radio Receiver Unit only. Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the RJ45 port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g, | £405.00 |
or call us for a quote
|
|
Tinytag Input Lead | ||||
CAB-3239 |
Tinytag CAB-3249 Voltage/Current Input Lead for connection of voltage and current input signals to Tinytag data loggers. Includes a 5-pin connection to logger and 1m flying tails. | Datasheet Size: (430.71 KB) |
£20.00 |
or call us for a quote
|
CAB-3246 |
Tinytag Current/MilliVolt/Count Input Lead for Connection of 2-Wire Input Signals to Tinytag Data Loggers. Includes a 2-Pin Connection to Logger. Cable Length 1.5m with Flying Tails. | £20.00 |
or call us for a quote
|