MSR175 Shock Transportation Data Logger
Kenny Laidlaw
Oct 01,2018
The MSR175 shock transportation data logger is the newest miniature logger from MSR.  The MSR175 ut...read more >
Tinytag Plus Radio Loggers
  • Tinytag Plus Radio Loggers
  • Tinytag Plus Radio MESH Network
  • Tinytag Connect Desktop Viewer

Tinytag Plus Radio Data Logging System

Quick Overview

Tinytag Plus Radio loggers are rugged and weatherproof, designed for outdoor, industrial and warehousing applications with multiple monitoring points. Individual units form a MESH network, sending data back to a main receiver. Units can record temperature, relative humidity, and can accept low voltage, current and count inputs, making them ideal for use with third-party sensors for pressure, flow rates and footfall. All the data can be viewied via Tinytag Explorer Connect software. Receiver units can be LAN or USB and compatible for use in the EU, or Austrialia. Loggers will operate for up to 1 year with up to 2 weeks data held at the default settings.

View Options

Details

This Tinytag wireless data logging system consists of a receiver which is connected to a PC, via USB or LAN, and a number of remote radio loggers. Each radio logger is a self-contained, battery powered unit that can receive, log, store and transmit data to any other radio unit in the MESH network and will find the best route around obstruction until is is received by the central receiver.

Each radio logger (or wireless data logger) has a line of sight range of up to 200 metres, but there is no limit to the number of loggers you can have, or to how far away you have them. Data will always find its way back to the PC because it can be relayed from one logger to another logger in range, until it finds its way back to the receiver. The loggers will dynamically adjust to deal with obstructions. If a logger is unable to find a path back to the receiver, its data is stored locally until such time as a path becomes available.

This combination of features delivers a very robust radio network which ensures that data is never lost during transmission. The radio software provides mechanisms for third party integration using Modbus or http accessible CSV files. This software is also fully compatible with 'wired' Tinytag products and existing users will find the interface familiar. Data from the receiver can be accessed over a network. Tinytag Plus Radio units also use the same 5 pin connector for inputs as the wired loggers.

Features

  • Radio licence-free and frequency, 869.8 MHz (EU Version), 917.8MHz (AUS Version
  • Self-configuring and easy to set up
  • Self-contained and battery powered
  • Local cache can store 2 weeks of readings @ 10 minute logging.
  • Low battery warning, LED on units and via software
  • User-replaceable batteries
  • Local recording
  • Fast access to information
  • Remote alarm signalling via e-mail
  • SMS messaging available using third party messaging services

 

Standard units are supplied with Alkaline 'C' Type batteries which are readily available and inexpensive to replace. Units supplied with a mains powered (via ACS-0044 Power Supply) or a 3.6V Lithium Battery option is available on request.

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
Tinytag Radio Units for Thermistor Probes
TGRF-4021-A
TGRF-4021-A

Tinytag Plus Radio Temperature Data Logger for One External Thermistor Probe. Measurement Range: -40 to +125°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation.

View FileDatasheet
   Size: (1.08 MB)
£285.00
or call us for a quote
TGRF-4022-A
TGRF-4022-A

Tinytag Plus Radio Temperature Data Logger for Two External Thermistor Probe. Measurement Range: -40 to +125°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation.

£320.00
or call us for a quote
TGRF-4024-A
TGRF-4024-A

Tinytag Plus Radio Temperature Data Logger for Four External Thermistor Probe. Measurement Range: -40 to +125°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation.

£345.00
or call us for a quote
 
Tinytag Radio Units for PT100 Probes
TGRF-4101-A
TGRF-4101-A

Tinytag Plus Radio Temperature Data Logger for One External PT100 Temperature Probe. Measurement Range: -50 to +600°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation.

£290.00
or call us for a quote
TGRF-4102-A
TGRF-4102-A

Tinytag Plus Radio Temperature Data Logger for Two External PT100 Temperature Probe. Measurement Range: -50 to +600°C, Resolution 0.02°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation.

£325.00
or call us for a quote
 
Tinytag Radio Units for PT1000 Probes
TGRF-4202-A
TGRF-4202-A

Tinytag Plus Radio Temperature Data Logger for Two External PT1000 Temperature Probe. Measurement Range: -200 to +100°C, Resolution 0.01°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation.

£325.00
or call us for a quote
TGRF-4201-A
TGRF-4201-A
Tinytag Plus Radio Temperature Data Logger for One External PT1000 Temperature Probe. Measurement Range: -200 to +100°C, Resolution 0.01°C. or better. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation.
£290.00
or call us for a quote
 
Tinytag Radio Units with a Temperature & Humidity probe
TGRF-4600-A
TGRF-4600-A

Tinytag Plus Radio Temperature Data Logger with One Temperature and Relative Humidity Probe. Measurement Range: -25 to +85°C, Resolution 0.01°C and 0.04%RH. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation, PBRF-8002 Probe, CAB-0034 Cable and a Probe Mounting Clip.

View FileDatasheet
   Size: (301.14 KB)
£380.00
or call us for a quote
TGRF-4602-A
TGRF-4602-A

Tinytag Plus Radio Temperature Data Logger with Two Temperature and Relative Humidity Probes. Measurement Range: -25 to +85°C, Resolution 0.01°C and 0.04%RH. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries suitable 12 months operation, Two PBRF-8002 Probes, Two CAB-0034 Cables and Two Probe Mounting Clips.

£465.00
or call us for a quote
 
Tinytag Radio Units for Voltage Inputs
TGRF-4703-A
TGRF-4703-A

Tinytag Plus Radio Data Logger for One 2.5V Voltage Input. Measurement Range: 0 to 2.5V, Resolution 100µV. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and One CAB-3239 (Tinytag Voltage Input Lead).

£290.00
or call us for a quote
TGRF-4743-A
TGRF-4743-A

Tinytag Plus Radio Data Logger for Four 2.5V Voltage Inputs. Measurement Range: 0 to 2.5V, Resolution 100µV. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and Four CAB-3239's (Tinytag Voltage Input Leads).

£350.00
or call us for a quote
TGRF-4704-A
TGRF-4704-A

Tinytag Plus Radio Data Logger for One 25V Voltage Input. Measurement Range: 0 to 25V, Resolution 1mV. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, One CAB-3239 (Tinytag Voltage Input Lead).

£290.00
or call us for a quote
TGRF-4744-A
TGRF-4744-A

Tinytag Plus Radio Data Logger for Four 25V Voltage Inputs. Measurement Range: 0 to 25V, Resolution 1m;V. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and Four CAB-3239's (Tinytag Voltage Input Leads).

£350.00
or call us for a quote
 
Tinytag Radio Units for Current Inputs
TGRF-4804-A
TGRF-4804-A

Tinytag Plus Radio Data Logger for One 20mA Current Input. Measurement Range: 0 to 20mA, Resolution 1µA. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and a CAB-3246 (Tinytag Current/Millivolt.Count Input Lead).

£290.00
or call us for a quote
 
Tinytag Radio Units for Pulse Counts
TGRF-4901-A
TGRF-4901-A

Tinytag Plus Radio Data Logger for One Pulse Count Input. Measurement Range: 0 to 32,737 Counts per Interval, Max Frequency 250 Counts/Second. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and a CAB-3246 (Tinytag Current/Millivolt.Count Input Lead).

£290.00
or call us for a quote
TGRF-4904-A
TGRF-4904-A

Tinytag Plus Radio Data Logger for Four Pulse Count Input. Measurement Range: 0 to 32,737 Counts per Interval, Max Frequency 250 Counts/Second. Logging Interval: 2 mins to 10 day with 2 Fully Programmable, Latching Alarms, per Channel with 1 sec to 10 days Alarm Delay. Red LED and Tinytag Explorer Connect Warnings with Email and SMS options. Reading are transmitter immediately, but Off-line Memory 2 Weeks @ 10 min logging. EU Radio frequency 869.88Mhz, power <5mW. Range up to 200m line of sight. IP67 Enclosure. Operating Temperature -20 to +55°C. Units are supplied with 2 x 1.5V Duracell Industrial ID1400 C Type Alkaline Batteries, suitable 12 months operation, and a CAB-3246 (Tinytag Current/Millivolt.Count Input Lead).

£350.00
or call us for a quote
 
Tinytag Radio Receiver Units
ACSRF-4030-PK-A
ACSRF-4030-PK-A
Tinytag Radio Receiver Unit complete with software, USB cable. Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the USB port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g,
£805.00
or call us for a quote
ACSRF-4040-PK-A
ACSRF-4040-PK-A
Tinytag Radio Receiver Unit complete with software, Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the RJ45 port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g,
£805.00
or call us for a quote
ACSRF-4030-A
ACSRF-4030-A
Tinytag Radio Receiver Unit only. Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the USB port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g,
£500.00
or call us for a quote
ACSRF-4040-A
ACSRF-4040-A
Tinytag Radio Receiver Unit only. Internal buffer memory for up to 45 hours, 90mm stub antenna user replaceable akaline battery size AA (x2) powered via the RJ45 port, Operational temperature range: -15 C to +60 C, Waterproof IP67 housing, dimension 140 x 155 x 80mm (including aerial) Weight: 280g,
£405.00
or call us for a quote
 
Tinytag Input Lead
CAB-3239
CAB-3239
Tinytag CAB-3249 Voltage/Current Input Lead for connection of voltage and current input signals to Tinytag data loggers. Includes a 5-pin connection to logger and 1m flying tails.
View FileDatasheet
   Size: (430.71 KB)
£20.00
or call us for a quote
CAB-3246
CAB-3246
Tinytag Current/MilliVolt/Count Input Lead for Connection of 2-Wire Input Signals to Tinytag Data Loggers. Includes a 2-Pin Connection to Logger. Cable Length 1.5m with Flying Tails.