Contact our technical sales team now to discuss your requirements
£0.00
You have no items in your shopping cart.
Click basket to edit.
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
REF | DESCRIPTION | DOWNLOADS | PRICE | ORDER ITEM |
---|---|---|---|---|
OLCT10N Fixed Digital Gas Detector - Catalytic Sensor | ||||
OLCT10N-001 |
OLCT10N Fixed Digital Gas Detector for Methane (CH4), Range 0-5% Volume, Accuracy ±1%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Certified to use in ATEX II 3GD zone. | Datasheet Size: (793.66 KB) |
£375.00 |
or call us for a quote
|
OLCT10N-002 |
OLCT10N Fixed Digital Gas Detector for Methane (CH4), Range 0-4.4% Volume, Accuracy ±1%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Certified to use in ATEX II 3GD zone. | £375.00 |
or call us for a quote
|
|
OLCT10N-003 |
OLCT10N Fixed Digital Gas Detector for Hydrogen (H2), Range 0-100%LEL. Accuracy ±1%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Certified to use in ATEX II 3GD zone. | £375.00 |
or call us for a quote
|
|
OLCT10N-004 |
OLCT10N Fixed Digital Gas Detector for Butane (C4H10), Range 0-100%LEL. Accuracy ±1%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Certified to use in ATEX II 3GD zone. | £375.00 |
or call us for a quote
|
|
OLCT10N-005 |
OLCT10N Fixed Digital Gas Detector for Propane (C3H8), Range 0-100%LEL. Accuracy ±1%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Certified to use in ATEX II 3GD zone. | £375.00 |
or call us for a quote
|
|
OLCT10N Fixed Digital Gas Detector - Poison Resistant Catalytic Sensor | ||||
OLCT10N-AP-001 |
OLCT10N Poison Resistant Gas Detector for Methane (CH4), Range 0-5% Volume. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £585.00 |
or call us for a quote
|
|
OLCT10N-AP-002 |
OLCT10N Poison Resistant Gas Detector for Methane (CH4), Range 0-4.4% Volume. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £585.00 |
or call us for a quote
|
|
OLCT10N-AP-003 |
OLCT10N Poison Resistant Gas Detector for Hydrogen (H2), Range 0-100%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £585.00 |
or call us for a quote
|
|
OLCT10N-AP-004 |
OLCT10N Fixed Digital Gas Detector for Butane (C4H10), Range 0-100%LEL. Accuracy ±1%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £585.00 |
or call us for a quote
|
|
OLCT10N-AP-005 |
OLCT10N Fixed Digital Gas Detector for Propane (C3H8), Range 0-100%LEL. Accuracy ±1%LEL. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 50mA typ. Operating temperature: -20 to +55°C. Life span: 48 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £585.00 |
or call us for a quote
|
|
OLCT10N Fixed Digital Gas Detector - Electrochemical Sensor | ||||
OLCT10N-204 |
OLCT10N Fixed Digital Gas Detector for Carbon Monoxide (CO), Range 0-300ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 36 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-205 |
OLCT10N Fixed Digital Gas Detector for Carbon Monoxide (CO), Range 0-1,000ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 36 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-213 |
OLCT10N Fixed Digital Gas Detector for Hydrogen Sulphide (H2S), Range 0-30ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 60 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-214 |
OLCT10N Fixed Digital Gas Detector for Hydrogen Sulphide (H2S), Range 0-100ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 60 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-231 |
OLCT10N Fixed Digital Gas Detector for Ammonia (NH3), Range 0-100ppm. Accuracy ±5ppm. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +40°C. Life span: 24 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £780.00 |
or call us for a quote
|
|
OLCT10N-232 |
OLCT10N Fixed Digital Gas Detector for Ammonia (NH3), Range 0-1,000ppm. Accuracy ±5ppm. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +40°C. Life span: 24 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £780.00 |
or call us for a quote
|
|
OLCT10N-216 |
OLCT10N Fixed Digital Gas Detector for Nitric Oxide (NO), Range 0-100ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 36 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-217 |
OLCT10N Fixed Digital Gas Detector for Nitric Oxide (NO), Range 0-300ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 36 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-219 |
OLCT10N Fixed Digital Gas Detector for Nitrogen Dioxide (NO2), Range 0-10ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 24 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-220 |
OLCT10N Fixed Digital Gas Detector for Nitrogen Dioxide (NO2), Range 0-30ppm. Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 24 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £505.00 |
or call us for a quote
|
|
OLCT10N-200 |
OLCT10N Fixed Digital Gas Detector for Oxygen (O2), 2 Year Sensor Life. Range 0-30% Volume. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -20 to +50°C. Life span: 28 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £455.00 |
or call us for a quote
|
|
OLCT10N-272 |
OLCT10N Fixed Digital Gas Detector for Oxygen (O2), 5 Year Sensor Life. Range 0-30% Volume, Accuracy ±1.5%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 2.5mA typ. Operating temperature: -40 to +50°C. Life span: 60 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. | £625.00 |
or call us for a quote
|
|
OLCT10N Fixed Digital Gas Detector - Infrared Sensor | ||||
OLCT10N-252 |
OLCT10N Infrared Fixed Digital Gas Detector for Carbon Dioxide (CO2), Range 0-5,000ppm, Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 20mA typ. Operating temperature: -40 to +50°C. Life span: 60 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. |
£595.00 |
or call us for a quote
|
|
OLCT10N-239 |
OLCT10N Infrared Fixed Digital Gas Detector for Carbon Dioxide (CO2), Range 0-5% Volume, Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 20mA typ. Operating temperature: -40 to +50°C. Life span: 60 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. |
£595.00 |
or call us for a quote
|
|
OLCT10N-241 |
OLCT10N Infrared Fixed Digital Gas Detector for Carbon Dioxide (CO2), Range 0-100% Volume, Accuracy ±3%. Output: RS485 Modbus RTU. Power Supply: 12-30vDC, Consumption 20mA typ. Operating temperature: -40 to +50°C. Life span: 60 Months. Plastic housing, 118 x 157 x 60mm, IP65. Non-Hazardous Area Only. |
£595.00 |
or call us for a quote
|
|
OLCT10N Calibration Device | ||||
6331163 |
Calibration Kit for CPS10 and OLCT10N Gas Detectors. Includes a bar and a magnetic Calibration Cap. |
£85.00 |
or call us for a quote
|