Contact our technical sales team now to discuss your requirements
£0.00
You have no items in your shopping cart.
Click basket to edit.
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
REF | DESCRIPTION | DOWNLOADS | PRICE | ORDER ITEM |
---|---|---|---|---|
XR440 Thermocouple/Millivolt Input Modules | ||||
MVT-11B |
MVT11B Thermocouple / Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV or Thermocouple Inputs, mV Range: ±11mV with a 12µV resolution. Thermocouple Input suitable for Type J, K, N, R, S, T, B, C, E Thermocouples. Module adds 9mm to overall length of an XR440. |
£132.28 |
or call us for a quote
|
|
MVT-22B |
MVT22B Thermocouple / Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV or Thermocouple Inputs, mV Range: ±22mV with a 24µV resolution. Thermocouple Input suitable for Type J, K, N, R, S, T, B, C, E Thermocouples. Module adds 9mm to overall length of an XR440. |
£132.28 |
or call us for a quote
|
|
MVT-50U |
MVT50U Thermocouple / Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV or Thermocouple Inputs, mV Range: 0-50mV with a 12µV resolution. Thermocouple Input suitable for Type J, K, N, R, S, T, B, C, E Thermocouples. Thermocouple input will read either high or low temperatures relative to ambient temperature reading. Module adds 9mm to overall length of an XR440. |
£132.28 |
or call us for a quote
|
|
XR440 Millivolt Input Modules | ||||
MVT-20U |
MVT20U Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: 0-20mV with a 5µV resolution. Module adds 9mm to overall length of an XR440. |
£132.28 |
or call us for a quote
|
|
MVT-100U |
MVT100U Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: 0-100mV with a 24µV resolution. Module adds 9mm to overall length of an XR440. |
£132.28 |
or call us for a quote
|
|
MVT-107B |
MVT107B Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: ±107mV with a 120µV resolution. Module adds 9mm to overall length of an XR440. |
£132.28 |
or call us for a quote
|
|
MVT-500U |
MVT500U Millivolt Input Module for the XR440 Pocket Logger. MVT Module converts the 4 input channels as follows: Channel 1: Precision thermistor for ambient temperature or CJC readings; Channels 2 & 4: Standard Inputs (0-5vDC, Pace Sensors or resistive inputs); Channel 3: mV Inputs, mV Range: 0-500mV with a 120µV resolution. Module adds 9mm to overall length of an XR440. |
£132.28 |
or call us for a quote
|