Absorbed Glass Matt Batteries
Absorbed Glass Matt (AGM) batteries are a quality alternative to the traditional wet lead-acid ranges. They are very robust and so able to deep cycle more than wet batteries. The electrolyte is contained in a glass mat which will not leak, even if casing is broken so are ideal for..
AQUAPLUS-PACKAGE
AquaPlus Package is suitable for monitoring Dissolved Oxygen, Conductivity and Temperature in a combined AquaPlus Probe. Probe Dimensions: 250mm length x 24mm diameter. IP68 permanent immersion to 30m, 1 month to 100m. Dissolved Oxygen: Range: 0-500.0%/0-50.00mg/L; Resolution: 0.1%/0.01mg/L; Accuracy: 0-200% (± 1% of reading, 200%-500%: ±10%). Conductivity (EC): Range: 0-200mS/cm..
BM25KITCHS25
BM25 Intrinsically Safe Trickle Charge Kit. Kit includes one IS power supply and wiring arrangement with 25m of cable...
CCDDT Column Type Compression Dome Top Load Cell
The CCDDT load cells are dome top column load cells designed for the measurement of compressive forces. The CCDDT can be used for applications including hydraulic press calibration, pile force measurement, jack force measurement, centre of gravity measurement systems and structural proof testing. Ranges 2 to 1,000 tonnes. Standard output..
CDI 5200 Compressed Air Flow Meter
The CDI5200 series of compressed air flow meter are suitable for small pipe diameters from ½" up to 1½". The flow meters provide a local display of compressed air flows with 4-20mA and pulse outputs, plus the option of Modbus RTU outputs. The flow meter clamps onto the pipe using..
CM121 Shadow Ring
The CM121 Shadow Ring is designed to be used with any Kipp & Zonen pyranometers, smart pyranometers, pyrgeometers or UV Radiometers to shield the sensor from direct radiation. The combination of one of these sensors and the CM121 offers a simple solution to the problem of measuring diffuse radiation from..
CMC-99 Multichannel Display/Logger
Multichannel, compact, based on LINUX meter/controller type MultiCon CMC-99 is ideal solution for applications where simultaneous measurement and regulation of numerous channels is required. MultiCon CMC-99 contains up to 48 analog inputs, 16 relay / SSR outputs and 8 current outputs satisfy 0-20mA standard. Controller is equipped with colour TFT..
CMP10 Pyranometer
The CMP10 Pyranometer is a Spectrally Flat Class A pyranometer which provides a faster response, better linearity and a wider measurement range than the CMP3 and CMP6. The CMP10 has been update to the CMP10X pyranometer. It maintains the improved thermopile detector, providing an expected output of 0-24mV based on..
ComNav G1 GNSS Satellite Compass
The ComNav G1 GNSS Satellite Compass provides true heading measurement with an accuracy of 0.5° RMS. The system uses differential GPS to measure heading and therefore is not subject to magnetic variation or deviation. Heading data is transmitted to an indicator or autopilot via a standard NMEA0183 or NMEA2000 data..
CTH Current Transducer – Through Hole Core Type
Through hole type hall effect current transducers for ranges 0-10 to 0-100 amps DC, with output options 0-5V, 0-10V and 4-20mA. Available with 12/24/48/110 VDC power supply, or 230VAC power supply...
CTX300 Gas Detector for Non-Hazardous Areas
The CTX300 gas detector is designed with a robust polycarbonate housing for gas detection in safe areas of Oxygen, Carbon Dioxide, Toxic and refrigerant gases. The polycarbonate housing is very durable and is not affected by harsh environments. The CTX 300 comes equipped with pre-calibrated sensor units and allows for..
Dipole 2.4GHz WiFi Antenna
Dipole WiFi frequency antenna for wall mounting with a bracket. The MULTIDIP is an omni-directional dipole antenna suitable for use with most WiFi, Bluetooth, 3G and 4G devices with a radio band frequency from 2.4GHz to 2.5GHz. Standard option is 5m cable with an SMA connector. Other standard radio connectors..
DLOG-4231
gSKIN Heat Flux Data Logger with autonomous, live and trigger logging modes. Internal memory for up to 2 million data points, logging rate 50Hz to 12 hours and internal rechargeable Lithium battery for up to 30 days logging, dependent on logging rate. 0.5m cable to TEG connector for connecting gSKIN..
DP65 Target Flow Meter
DP65 Target Flow Meter is a rugged and reliable mechanical flow meter is ideal for a wide range of media including gases and liquids. The fluid flows through the meter and displaces the target disc with a force proportional to flow. The meter can handle both clean liquids and liquids..
DPT-FLOW-5000-D
DPT-Flow-5000-D - Air Flow and Velocity Transmitter with Display. Designed for Building Management Automation Systems with measurements for Volume Flow, Velocity and Static and Differential Pressures. Power Supply: 24V ±10% @ <1W. Measuring Range: 500 - 5000 Pascals. Accuracy: >125 Pa, ±1.5%, ±1 Pa and <125 Pa, ±1.5%, ±2 Pa...
DPT7000-R8
DPT-R8 Multi-Range Differential Pressure Transmitters for Air Pressure. 8 Jumper selectable ranges: 0-1000, 0-1500, 0-2000, 0-2500, 0-3000, 0-4000, 0-5000 or 7000 Pa. Selectable output of 4-20mA or 0-10vDC, Accuracy 1% ±2Pa < 125Pa (1% ±1Pa >125 Pa). Power Supply: 24vDC, ±10%. ABS Enclosure with IP54 Rating. Dimensions: 90 x 95..
EL-CC-2-004
EasyLog Pharmaceutical Temp & RH Logger for Ambient Goods. Temperature Range: -30 to +70°C. Alarm Thresholds: Low: +8°C; High +25°C. Logging Interval: 10 Mins, Internal Memory: 32,637 temp & 32,637 %RH readings (220 days logging). Battery Life: 12 Months. Start button and status LEDs to give a quick indication of..
EL-USB-TC
EL-USB-TC. Thermocouple Temperature datalogger with a USB port for downloading the data. Each logger is supplied with a basic K Type thermocouple for a measurement range of 0 to 400 C. Logger is suitable for use with K, J & T type thermocouples with wider measurement ranges, memory for 32,510..
EL-USB-TP-LCD
EL-USB-TP-LCD. Thermistor Temperature data logger with built in LCD display and USB port for downloading the data. Each logger is supplied with a 1.0m type 2 thermistor probe for a measurement range of -40 to +125°C. Logger is only suitable for use with thermistor probes using a 3.5mm jacket socket/plug..
EL-WIFI-VACX
EL-WiFi-VACX Wireless Vaccine Monitoring Kit with Alarm Warning Light, Sounder and email Alarms. The 3m thermistor temperature probe are immersed in Glycol filled bottles to provide a temperature reading representative of the vaccine temperature. Temperature range is -20 to +60°C with a ±0.1°C accuracy and a resolution of 0.01°C. The..
Excelog 6 Handheld Temperature Data Logger
The Excelog 6 is a portable 6-channel handheld temperature data logger that features a backlit 2.83-inch touch screen interface for real-time monitoring and configuration. It accommodates up to four thermocouple sensors (Types J, K, T, R, S, N, or E) and two RTD sensors (such as PT100 or PT1000) simultaneously,..
Excelog One Thermocouple Data Logger and Simulator
The Excelog One is a portable single channel handheld thermocouple data logger and simulator. It can log or simulator thermocouple sensors (Types J, K, T, R, S, N, or E), displaying live readings on screen. Designed for flexibility in field or lab work, the device logs data directly to its..
EXCELOG-6
Excelog 6-channel temperature data logger with 2.83 inch TFT display. 6 channels are split, 4 Thermocouples (Types J, K, T, R, S, N, or E) and 2 RTD (PT100, PT200, PT500 or PT1000) sensors. USB port for rechargeable Li-ion battery for up to 96 hours logging and data downloading. 32GB..
EXCELOG-ONE
Excelog One thermocouple data logger and simulator with built-in rechargeable battery, data storage and USB cable. Suitable for thermocouple sensors (Types J, K, T, R, S, N, or E). Backlit colour display and Modbus Interface for integration to third-party software. English, Spanish, French, German, Italian, Chinese and Japanese languages. 1.5MB..