Tinytag CO2 Logger
The Tinytag CO2 logger allows the monitoring of Carbon Dioxide levels in a room and builds up a clear profile of gas concentrations over time. There are two loggers available, covering a range of 2,000ppm and 5,000ppm. Large memory capacity of 32,000 readings and 1 programmable alarm. Logging rate 1..
0362910-002
CMP 11 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². Supplied with waterproof 2-pin plug connector with 10m of pre-wired yellow signal cable...
0362910-004
CMP 11 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². Supplied with waterproof 2-pin plug connector with 25m of pre-wired yellow signal cable...
0362910-005
CMP 11 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². Supplied with waterproof 2-pin plug connector with 50m of pre-wired yellow signal cable...
0362920-014
CMP 21 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². 10K Thermistor output. Supplied with waterproof 4-pin plug connector with 25m of pre-wired..
CR-0100
The Tinytag Dry Shipper allows the monitoring of products being shipped in cryogenic vessels employing Nitrogen dry vapour, generating low temperatures from evaporating liquid Nitrogen. The disp[ay securely mounts to the flask lid, with the probe extending into the tank via an insulating plug. Large memory capacity of 32,000 readings..
Tinytag Dry Shipper
The Tinytag Dry Shipper allows the monitoring of products being shipped in cryogenic vessels employing Nitrogen dry vapour, generating low temperatures from evaporating liquid Nitrogen. The disp[ay securely mounts to the flask lid, with the probe extending into the tank via an insulating plug. Large memory capacity of 32,000 readings..
0362920-015
CMP 21 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². 10K Thermistor output. Supplied with waterproof 4-pin plug connector with 50m of pre-wired..
0362920-024
CMP 21 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². PT100 output. Supplied with waterproof 8-pin plug connector with 25m of pre-wired yellow..
CA-17/39
Sealed Gel Battery. Storage Capacity 191Ah, Output 12V. Dimensions: 530 x 209 x 214mm. Weight: 57.4Kg..
CMP6 Pyranometer
The CMP6 Pyranometer is a Spectrally Flat Class B pyranometer that has a similar detector to the CMP3 but with improved performance. The CMP6 uses a 64-junction thermopile detectors and provides an expected output of 0-30mV based on a sensitivity of 5 to 20µV/W/m². The CMP6 has two, 2mm thick,..
EL-USB-CO Carbon Monoxide Data Loggers
The EL-USB-CO is a USB data logger that measures and stores up to 32,510 Carbon Monoxide (CO) readings over a 0 to 1000 ppm (EL-USB-CO300 0 to 300ppm) measurement range. Loggers have an integrated USB port that can be plugged directly into a PC for configuration and downloading the logged..
GSKIN DLOG Heat Flux Data Loggers
GSKIN DLOG's are a range of custom designed MSR loggers that are suitable for connecting to gSKIN Heat Flux sensors fitted with a TEG connector. The loggers have an internal memory for up to 2 million readings and have three logging modes: Autonomous; Live Operation; and Triggered. Loggers are available..
Internal Light Level Sensors
These light level sensors return a linear 0-10vDC signal representing the Lux level at the photo-diode cell. The sensors are typically used in lighting strategies to optimise energy efficiency through dimming and/or disabling of lights as required or as sensors to monitor light levels over a period of time. The..
Intrinsically Safe WindObserver Ultrasonic Anemometer
The WindObserver IS system is an Intrinsically Safe Ultrasonic Anemometers developed specifically for use in hazardous areas and offshore applications. The full system required no regular maintenance for a reliable low maintenance wind speed and direction sensor. The ATEX, IECEx & UKEX certification ensures that the wind system may be..
Legionnaires Thermometer Kit
Legionnaires' Thermometer kit can be used to monitor the temperature of both storage tanks and pipework that form part of the water system. The kits include various probes to allow you to take measurements in various locations, including immersion, surface or PTFE wire probes...
MiniAir20 Robust Vane Anemometers
The MiniAir20 robust vane anemometers can be used to monitor aggressive air flows with the MC 4.0 Handheld Display. The probes are available with Steel Micro and Mini and Brass Macro heads and with flow ranges of 20m/s and 40m/s. The probes are designed to be automatically recognised by the..
PA-699 Differential Air Pressure Sensor
The PA-699 is a differential air pressure sensor incorporating a proved ceramic fulcrum lever technology. They deliver calibrated, temperature-compensated sensor signals, available as standard voltage or current outputs. They are ideal for registering low air flow in air conditioning systems and for the measurement of fine pressures in environmental, laboratory..
PA-699-01
PA-699-01 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges ±30, ±50 and ±100 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-01-V
PA-699-01-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges ±30, ±50 and ±100 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-02
PA-699-02 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-30, 0-50 and 0-100 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-02-V
PA-699-02-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-30, 0-50 and 0-100 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-04
PA-699-04 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-100, 0-300 or 0-500 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-04-V
PA-699-04-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-100, 0-300 and 0-500 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..