TXIsoLoop Loop Powered 4-20mA Isolator
Loop isolators provide signal protection by electrically isolating the input signal from the output. TxIsoLoop-1 and TxIsoLoop-2 simplify your application and avoid the undesirable ground loops by providing single and dual loop galvanic isolation. The 0/4-20 mA input is measured and an identical isolated signal is reproduced at the output...
TxIsoPack Isolated Temperature Transmitter
The TxIsoPacks are fully isolated 4-20mA two-wire loop powered temperature transmitters for head mount assemblies. Units have a built-in USB port to allow a configuration of sensor type and range via a PC. The TxIsoPack can be used for PT100 (2, 3 or 4-wire), Thermocouples (Type K, J, R, S,..
PB-7005-3M
PT1000 Flat Cable Cryogenic Probe for use with TGP-4205 & TV-4204 loggers. PT1000 (Class B) Temperature range -200 to 150°C. The stainless steel probe is 50mm long and 6mm in diameter with a 3m cable. IP67 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy..
U50R-REMOTE-232
ToughSonic Remote 50R Ultrasonic Level Sensor, with RS232 serial Modbus RTU interface. Optimal range 305mm to 9.1m, max range 15.2m. Power Supply 10-30vDC (typical 30mA @ 24vDC). Marine grade 316 Stainless Steel IP68 housing with rear 1½" NPT thread mounting and 2m cable. Operating temperature -40 to +70°C, 0-100%RH. Dimensions..
U50R-REMOTE-485
ToughSonic Remote 50R Ultrasonic Level Sensor, with RS485 serial Modbus RTU interface. Optimal range 305mm to 9.1m, max range 15.2m. Power Supply 10-30vDC (typical 30mA @ 24vDC). Marine grade 316 Stainless Steel IP68 housing with rear 1½" NPT thread mounting and 2m cable. Operating temperature -40 to +70°C, 0-100%RH. Dimensions..
U6
1 inch Domestic Diaphragm Gas Meter with 3/4 BSP fittings. Qmax 6 m3/h, Fireproof to EN1359, Transco Standard Domestic Meter. OFGEM Approved, BS746 Connections..
U6-PULSE
1 inch Domestic Diaphragm Gas Meter with 3/4 BSP fittings. Qmax 6 m3/h, Fireproof to EN1359, Transco Standard Domestic Meter. OFGEM Approved, BS746 Connections. Fitted with pulse output, 1 pulse = 0.01m3 [10 litres]..
U9VL
9V Lithium Manganese Dioxide Battery. Capacity 1200mAh. Suitable for use with the XR440 Pocket Logger...
UA-CLIC-15
1½" PVC Clamp Mounting Bracket for ToughSonic 30. Fits a 1½ inch cylinder sensor...
UKAS Calibration of LEO Gauges
LEO Pressure Gauges are calibrated in accordance with ISO/IEC 17025:2005 by UKAS accredited calibration laboratories. This services covers both your own gauges for recalibration and brand new gauges for their initial calibration. UKAS certification is available on the entire range of LEO gauges as well as any other pressure sensors..
ULTRASHOCK
UltraShock Dynamic Environment Data Logger with two integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: Triaxial Acceleration: ±15g, ±100g and ±300g, Temperature: -20 to +60°C, Relative Humidity: 0 to 95%RH and Pressure: 100 to 1300mBar Pressure. Internal memory 660,000 readings per channel. Configurable logging rates: Acceleration 1024Hz to every..
UltraShock Temperature, Humidity, Pressure and Tri-Axial Shock Data Logger
The UltraShock is a battery powered data logger to measure and record temperature, humidity, pressure and peak tri-axial acceleration levels at user defined interval. The unit is an all-in-one compact, portable device that has a non-volatile solid state memory for up to 4 million measurements. Standard units are suitable for..
ULTRASHOCK-100
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±100g Triaxial Acceleration; -20 to +60°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-100-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±100g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-250
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±250g Triaxial Acceleration; -20 to +60°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-250-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±250g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-5-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±5g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-50
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±50g Triaxial Acceleration; -20 to +60°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-50-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±50g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
Ultrasonic Anemometer Calibrations
Omni Instruments can provide a calibration certificates for our ultrasonic anemometers, WindSonic, WindObserver and WindMaster anemometers. Calibration are done in a wind tunnel and units can be fixed with a varied wind speed, or rotated with fixed wind speeds. Calibration work is undertaken using wind tunnels traceable to national standards..
USB-010100
USB Meter Reader for wireless meter reading of Multical 402 Ultrasonic Heat Meter. Starter pack including USB Reader, internal antenna and Power Pack. The Kamstrup USB Meter Reader is used for quick and simple reading of Kamstrup electricity, heat, cooling and water meters fitted with a radio module with EU..
USB-AD
USB-AD USB Data Acquisition Cable. The 1.1m cable consists of a USB 2.0 port connecting to a 37-pin D-Sub Female Connector. The 37-pin connector allows up to 16 Analogue Inputs (±5V), 1 Analogue Output (±5V) and 8 Digital Input/Outputs, Plus One 32-Bit Counter Input to be connected. 12-Bit Resolution and..
USB-AD14F
BMCM USB Data Acquisition Unit. 16 Analogue Inputs (Range: ±10V) with a 14-bit Resolution and 20kHz Sampling Rate across all used channels, plus 8 Digital Inputs, 8 Digital Outputs, including one 16-bit Counter Input, and 1 Analogue ±5V Outputs. Power Supply: 4.5-5.5V from USB connection to the PC, max 100mA...
USB-AD16F
BMCM USB Data Acquisition Unit. 16 Analogue Inputs (Range: ±10V, ±5V, ±2V or ±1V) with a 16-bit Resolution and 250kHz Sampling Rate across all used channels, plus 4 Digital Inputs, 4 Digital Outputs, including one 16-bit Counter Input, and 2 Analogue Outputs (±10V with 16-bit Resolution). Power Supply: 4.5-5.5V from..