DRAN30-24
DIN Rail Mounted Power Supply. Input 85-264vAC, Output 24vDC @ 1.25A (30W). Dimensions: 40.5 x 114 x 90mm, with spring terminals...
DSCC Load Cell
DSCC Pancake/Low Profile - Bi-directional Load Cell. Ranges 0-5kN to 1000kN. Output 2mV/V, accuracy 0.05%. DSCC load cell is a stainless steel construction with an IP65 rating...
DSCRC Load Cell
DSCRC Pancake/Low Profile - Bi-directional Load Cell. Ranges 200N to 2,000N, Output 2mV/V, accuracy 0.1%. DSCRC load cell is a stainless steel construction with an IP65 rating...
DT80
Datataker DT80 series standalone data logger with 5-15 analogue inputs (universal input type) and 12 digital I/O's, expandable up to 300 channels via CEM-20 modules. Serial input suitable for Modbus, NMEA, ASCII serial input. The logger has an internal non volatile memory for up to 10,000,000 readings which can be..
DT82E
Datataker DT82E Series Environmental Data Logger, with 2-6 analogue inputs (universal input type) and 8 flexible digital channels. Serial input suitable for Modbus, NMEA, ASCII and SDI-12 serial input. The logger has an internal non volatile memory for up to 10,000,000 readings which can be expanded with a USB memory..
DT82I
Datataker DT82I Series Industrial Data Logger, with 2-6 analogue inputs (universal input type) and 8 flexible digital channels. 2 serial 'Smart Sensor' ports suitable for RS232, RS422 and RS485 inputs. The logger has an internal non volatile memory for up to 10,000,000 readings which can be expanded with a USB..
DT85
Datataker DT85 series standalone data logger with 16-48 analogue inputs (universal input type) and 12 digital I/O's, expandable up to 800 channels via CEM-20 modules. Serial input suitable for Modbus, NMEA, ASCII and SDI-12 serial input. The logger has an internal non volatile memory for up to 10,000,000 readings which..
DTI-EMF-DN50-HR-PN16
DTI-EMF Series Electromagnetic Flow Meter. DN50 - DIN Flanged, 50mm Pipe Diameter. HR - Hard Rubber Lining. PN16 - 16 Bar Pressure Rating. Electrodes, Power Supply, and any other additional options, must be purchased with this flow meter...
DUT-E
DUT-E capacitance fuel level sensor, ranges 1400, 1000, 700, 500, 350, 250, 180 mm, available with 1.5-4.5v or 1.5-9.5v output. Power supply10-50v DC @ 10mA. Operating temperature -40 to +80 deg C, accuracy +/-1% FSD...
DUT-E Fuel Level Sensors
The DUT-E Fuel Level Sensor is designed for fuel level measurement in tanks of vehicles and stationary tanks. Probe lengths are available in 700 and 1000mm lengths, but can be reduced by up to 30% without the need of any re-calibration. Output options for CANBus, Modbus, voltage, frequency or 4-20mA...
DUT-E-2BIO-I-700
DUT-E 2 BIO Capacitance Fuel Level Sensor. Ideal for Biodiesel and long distance vehicle fuel tanks. Power supply 10-50vDC @ 10mA. Operating temperature -40 to +80°C, accuracy ±1% FSD. Output: 4-20mA, Probe length: 700mm..
EGW1-110-1-IA3-MB-HT
EGW1 - HART to Modbus ASCII, RTU, TCP Protocol Converter. 1 HART ports, 1 x RS232, 1 isolated RS485 Serial Port and 1 x Ethernet Port 10/100Mbps. DIN Rail mounted industrial enclosure with terminal blocks. Power supply: 10-30vDC, consumption 80mA @ 12vDC. Dimensions: 100 x 22.5 x 112mm. Operating Temperature:..
EGW1-2ETH-IA3-MB – Serial Modbus To Modbus TCP Converter with Dual Ethernet Switch
The EGW1-2ETH module is used to connect any industrial equipment with Modbus RTU or ASCII, to a TCP / IP protocol to transmit data across an two RJ45 Ports. An EGW1-2ETH unit is available 4 RS232/RS485 ports , or a single isolated RS232/485 or RS422 port...
EGW1-4B0-00-2ETH-IA3-MB
EGW1 - Serial Modbus ASCII/RTU to Modbus TCP Protocol Converter with Dual Ethernet Switch. 4 x RS232/RS485/RS422 Serial Ports and 2 x RJ45 Ethernet Port. DIN Rail mounted industrial enclosure with terminal blocks. Power supply: 10-30vDC, consumption 70mA @ 12vDC. Dimensions: 100 x 22.5 x 112mm. Operating Temperature: -15 to..
EGW1-4B0-00-IA3-MB
EGW1 - Serial Modbus ASCII/RTU to Modbus TCP Protocol Converter. 4 x RS232/RS485/RS422 Serial Ports and 1 x RJ45 Ethernet Port. DIN Rail mounted industrial enclosure with terminal blocks. Power supply: 10-30vDC, consumption 70mA @ 12vDC. Dimensions: 100 x 22.5 x 112mm. Operating Temperature: -15 to 65°C...
EL-CC-1-001
EasyLog Cold Chain Temperature Logger for Chilled Goods. Temperature Range: -30 to +60°C. Alarm Thresholds: Low: +2°C; High +8°C. Logging Interval: 10 Mins, Internal Memory: 32,600 readings (220 days logging). Battery Life: 12 Months. Start/Stop button and status LEDs to give a quick indication of any alarm conditions. Windows software..
EL-SIE-1
EL-SIE-1 Temperature Data Logger with Display. Temperature range -18 to +55°C, Accuracy ±0.2°C. Over 1 million reading internal memory. Selectable logging intervals with configurable start time and high & low alarms. An integrated USB port for configuration and downloading logged data. 2 x AAA batteries provides more than 1 years..
EL-USB Loggers for Temperature Monitoring
The EL-USB loggers in this section can be used to monitor temperatures with internal and external thermocouple sensors. Each logger has a different measurement range (-10 to +50°C up to -200 to +1,350°C) and internal memory (4,080 up to 32,510 readings). Loggers have an integrated USB port that can be..
EL-USB-1-LCD
The EL-USB-1-LCD is a USB Temperature Data Logger with a built-in LCD display. Temperature range -35 to +80°C (-31 to +176F). Memory for 16,378 temperature readings with configurable start time and high & low alarms. Logging intervals of 10 secs, 1 mins , 5 mins, 30 mins, 1 Hr, 6..
EL-USB-2
EL-USB-2 Temperature & Relative Humidity data logger with a USB port for configuration and downloading data. Measurement ranges -35 to +80°C (Typical accuracy ±0.5°C) and 0 to 100%RH (±3%RH), memory for 16,382 temperature & 16,382 humidity readings. The replaceable longlife Lithium battery will allow for up to 1 year. The..
EL-USB-3
EL-USB-3 data logger for a 0-30V input with an integrated USB connection. Internal memory for up to 32,510 readings. The data logger features a pair of screw terminals and is supplied complete with a set of measurement leads terminating in crocodile clips, windows software and internal replaceable Lithium battery...
EL-USB-4
EL-USB-4 data logger for a 4-20mA current input with an integrated USB connection. Internal memory for up to 32,510 readings. The data logger features a pair of screw terminals and is supplied complete with a set of measurement leads terminating in crocodile clips, windows software and internal replaceable Lithium battery...
EL-USB-5
The EL-USB-5 data loggers are suitable for Counter, Event and Digital State change monitoring with an internal memory for 32,510 events. Logging is available for event capture and event counting at up to 100Hz. The data logger features a pair of screw terminals and crocodile clip connectors for connecting the..
EL-USB-CO
EL-USB-CO. Carbon Monoxide data logger with a USB port for downloading the data. Measurement range 0 to 1,000ppm, memory for 32,510 CO readings. The logger has a user programmable alarm threshold with LED and buzzer warnings. The replaceable internal battery is a long-life lithium battery which will last for up..