Static Pressure Sensor Heat Sink
This heat sink enables standard pressure sensors to be used on systems where the medium has a higher temperature than the sensor allows. The cooling fins effectively transfers the heat, depending on the ambient temperature. Systems with medium temperatures of up to 260 degrees C can be monitored without harming..
SUBSEA-LOGGER-COMMS-2
Serial interface cable assembly with 8 pin female inline miniature subcon connector ( to subsea housing ) to USB ( PC connection ), supplied with drivers for USB port setup...
SUBSEA-SW2-CRE
Subsea switch assembly comprising of square mounting plate 200 x 200 x 8mm thick, 316 stainless steel, with rotating switch bar (190 x 50 x 25mm), fitted with 2 permanent magnets. Subsea housing with proximity switch mounted behind the square mounting plate with relay changeover contacts rated at 3 amps..
SW10026.6
Steel Pitot Tube for measuring static and dynamic pressure in air flows. 3mm diameter tube with 300mm probe length. Suitable for temperatures up to 350°C..
TP-60-OQ
Stainless Steel Thermal Barrier for OQ610-S data loggers. Dimensions: 250mm x 320mm x 65mm, weight 8Kg approx. Thermal capacity of 120 min at 100°C or 45 min at 300°C (max internal temp 70°C)...
TR-5101
Fluoropolymer coated temperature sensor for TR42 . Flexible probe, 45mm x 2.2mm diameter, measurement range -60 to +155°C. response time 80 seconds in air, 7 seconds in water. Accuracy Avg. ± 0.3°C at -20 to 80°C Avg. ± 0.5°C at -40 to -20°C, 80 to 110°C. Avg. ± 1.0°C at..
TST100
TST100 1-Wire Temperature Sensor. Suitable for a temperature range of -40 to +85°C. 8mm flat aluminum head probe head with mounting hole. IP65 rated with 1m of cable with soldered wires for direct connection to controller screw terminals...
TT-OR-CVO
TT-OR-CVO Outside Air Temperature Sensor with a PTFE radiation shield suitable for monitoring temperature in an external environment. Housing is a grey, IP65, PC/GF (Halogen free, flame retardant & UV stablised) with a PT100 temperature sensing elements housed in a 40 x 16mm diameter radiation shield. Selectable 4-20mA or 0-10vDC..
Tunnel Air Flow Measurement TMS3000
The TMS3000 is designed for air flow measurement for ventilation control in road tunnels. The TMS3000 system is specifically designed for working under conditions prevailing in road tunnels. In the road tunnel area only robust mechanical sensors made of stainless steel are used and the the signal processing electronics are..
TURB-1000
1000NTU calibration solution 500ml...
TX2-12021
Tango TX2 Two Gas Detector for Carbon Monoxide (CO), Range 0-1000 ppm in 1ppm increments & Hydrogen Sulphide (H2S), Range 0-500 ppm in 0.1ppm increments. Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for 3 months at 10 second interval plus 60 alarm events. The replaceable internal..
USB-CAP-30V
Spare/replacement cap for the EL-USB-3. The USB-CAP-30V provides the connection method to the current loop to be recorded by the EL-USB-3 data logger...
VLS-RT5
Reflective tape for VLS optical sensor. 25mm x 5m reel...
VM-6360-SOFT
Windows software for VM-6360 hand held vibration meter, including USB download cable...
WC30CO2A
CTX 300 Fixed Gas Detector. Infrared Carbon Dioxide (CO2) Cell, Range 0-5000ppm (0.5%). Accuracy ±2% (% at PA full scale), response time less than 20 seconds. Operating temperature -40 to +50°C. Life span 60 months...
WPH-PULSE-OPTION-K=100
Pulse output option for WPH hot water meters 100Ltr/pulse..
WPI-PULSE-OPTION
Optional pulse output for the WPI Irrigation Water Flow Meter. Reed switch generates a pulse at 0.1 or 1 m³ for the DN50 to DN150 meters and 1 or 10m³ for the DN200 to DN300, depending on the positioning inside the meter...
WSERIAL-N
wSerial Wireless Node, provides serial connection to send data back to a wSerial-C concentrator. Power supply 10-30vDC, operating temperature -5 to +65°C, DIN rail mounting. 1 x RS232/RS485/USB transparent serial port, supports MODBUS protocol RTU/ASCII. 2.4GHZ Zigbee radio communications, maximum range 2Km line of sight. Maximum number of remote nodes..
XM269C
GSKIN Small Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 1.5µV/(W/m²), response time 0.7s. Plate sensing area is 4.4 x 4.4mm with a 0.5mm thickness. 1m flying lead for direction connection to meter or data logger..
ZO-150
150ml Bottle of Zero Oxygen Solution for Direct Calibration...
ZO-600
500ml Bottle of Zero Oxygen Solution for Direct Calibration...
17134479
Replacement Hydrogen Sulphide (H2S) Sensor for Ventis MX4 gas detector...
180-170
Heavy duty hammer moisture meter probe. Two insulated pins ensure the measurements can be taken at varying depths. Ideal for measuring moisture in a variety of wood and similar materials. Supplied with a one metre PVC lead and BNC connector suitable for use with the 7000 Moisture Meter..
3111-N
3111 Slim Series Isolated Thermocouple Converter suitable for conversion of K and J Type Thermocouple input to a 0/4-20mA, 0/1-5V or 0/2-10V output signal. Response time: less than 30ms or 300ms, Accuracy better than 0.05% of selected range, or 0.5°C. Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing...