Gen II Wireless Data Logger for Temperature, Humidity and Process Signals
The GENII wireless data logging system connects sensors and process signals via radio transmitters to a central base station with a built in data logger. The system can handle up to 250 channels and has a range of up to 2-3 kilometres. Repeaters can be used to extend the range...
SQ Series Data Loggers with 8-16 Analogue Inputs
The SQ Series data loggers are a range of general purpose data loggers with universal inputs suitable for monitoring current, voltage, resistance, temperatures and digital channels for alarms and triggering. Loggers have 8 differential/16 single-ended, 8 digital state inputs and 4 digital outputs. The logger can be used as a..
WSR GEN II Telemetry System
The WSR GEN II Telemetry System works as a receiver unit for GEN II transmitters to provides an analogue output for inputs to connected GEN II transmitters. The WSR is a self-contained mains powered receiver and output unit with built-in batteries providing 48 hours of operation in the event of..
RC250 Modbus GEN II Receiver
The RC250 Modbus GEN II Receiver can be used as a receiver unit for the GEN II transmitters to provide a serial Modbus output for up to 160 active channels. The RC250 is a self-contained mains powered receiver unit with built-in batteries providing more than 24 hours of operation in..
Squirrel 450/850 Series Data Logger
The Squirrel 450/850 series is a cost effective portable data logger with a maximum of 4 or 8 universal inputs. In common with its bigger brother, the Squirrel 1000 series data logger, the 450 and 850 series are equipped with impressive specifications, long battery life and a three year guarantee...
Squirrel OQ610 Temperature Data Logger
The OQ610 temperature data logger is suitable for a wide range of temperature recording applications in industry, research and development. It is available as a standalone temperature logger or as part of a complete system for through process monitoring in the food and paint industries. The OQ610 can accept up..
1000 Series Squirrel
The basic Squirrel data logger is small and portable and consists of the CPU and battery pack. The CPU contains the processor, memory, power connector, display, RS232 serial connection, a pulse input, an 8 bit digital signal input and output connector...
OQ610-S Through Process Data Logging Systems
The OQ610-S data logger is suitable for taking up to 6 K or T type thermocouple temperature readings for heat treating products in your manufacturing process. The logger is housed in one of the standard, or custom, thermal barriers for protection for the required process temperature and duration. We can..
OMK610 Squirrel Oven Logging System
The OMK610 Squirrel oven logging system includes everything you need for oven temperature profiling and paint cure calculations in one easy to use and convenient system. The OMK610 is built from over 40 years experience in the manufacture of oven recorders for the coatings industry. The current OMK610 is designed..
RX250-AL GEN II Receiver Loggers
The RX250-AL GEN II Receiver can also work as a central unit for the GEN II transmitters and has a built in data logger to handle up to 250 channels over 125 transmitters. The RX250-AL is a self-contained mains powered receiver unit with built-in batteries providing more than 24 hours..
GEN II Wireless Energy Monitoring System
The GENII wireless energy monitoring system is able to cover a wide range of parameters. Transmitters are available for direct connections to ND-350 Power meters, U6 Gas meters, various heat meters, flow meters and other energy monitoring devices. A system can be customised to your requirements, with battery or externally..
RP250GD
GEN II Radio Repeater. Supplied with AC power supply, 24 hour built-in standby battery (6 x NiMh AA batteries), antenna and integral LCD display. Repeater will extending the effective range of GEN II receiver units and signal paths of transmitters in poor coverage areas...
DARCA SOFTWARE
DARCA Software is used with the GEN II telemetry systems to help manage and analyse the data collected from the various different GEN II transmitters. DARCA Lite, DARCA Plus, DARCA Heritage and DARCA Secure. The table below shows a breakdown of the different versions and what each can provide...
EL6XNIMH
6 x NiMh batteries for RX250AL, RX250ALD or WSR GEN II receiver units...
EL7.2NIMH
Plug-in rechargeable 7.2V NiMh pack of 6 batteries for RP250GD, RC250 or GD-47 GEN II radio units...
SQS200
Single user license for professional configuration and analysis software for SQ16 and SQ16 PLUS data loggers. The SquirrelView+ software provides full data analysis, on-line graphing, meter to Excel, export to Excel and Logger contact scheduling. Licence valid for 2 years..
SQS300
Multi user license for professional configuration and analysis software for SQ16 and SQ16 PLUS data loggers. Unlimited use of the SquirrelView Plus software within a single organisation. The SquirrelView+ software provides full data analysis, on-line graphing, meter to Excel, export to Excel and Logger contact scheduling. Licence valid for 2..
LW-ANT/SMA
Lightweight indoor/outdoor dipole antenna with 5m lead, SMA plug and mounting hardware..
GSM-MDM-STUB
GSM modem kit compromising modem, logger cable and direct attach stubby antenna..