SMP6 Smart Pyranometer
The SMP6 Pyranometer is a Class B pyranometer with industry standard digital and analogue amplified outputs. The SMP6 is identical to the CMP6 pyranometer but includes an RS485 Modbus RTU interface allowing for an improved response time and rescaleable, temperature corrected measurement data. The SMP6 has a dual-dome construction with..
Tinytag Software, Starter Packs and Interface Cables
Tinytag Explorer software can be used with all Tinytag Data Loggers. This invaluable data logging software package makes configuring, viewing and analysis of data easy. It also supports multiple language including English, Chinese, German, Spanish, etc. The software is supplied with a site licence which means it can be installed..
0364910-004
CUV 5 Broadband UV Radiometer. For measurement of global combined UV-A and UV-B irradiance. Single 2mm glass dome. Integrated leveling. Sun shield. Spectral range 280 - 400nm (50% points), response time less than 1 sec (95%), sensitivity 300-500µV/Wm² (variation ±0.1% per °C), operating temperature -40 to +80°C. Photo-diode detector, diffuser,..
0364910-005
CUV 5 Broadband UV Radiometer. For measurement of global combined UV-A and UV-B irradiance. Single 2mm glass dome. Integrated leveling. Sun shield. Spectral range 280 - 400nm (50% points), response time less than 1 sec (95%), sensitivity 300-500µV/Wm² (variation ±0.1% per °C), operating temperature -40 to +80°C. Photo-diode detector, diffuser,..
0368900-034
CHP 1 Pyrheliometer. Quartz window, integrated alignment aids, rain shield. Spectral range 200-4000nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm², (variation < 0.5% from -20 to +50°C). Calibration certificate includes temperature dependency from -20 to +50°C in 8 steps..
0368900-035
CHP 1 Pyrheliometer. Quartz window, integrated alignment aids, rain shield. Spectral range 200-4000nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm², (variation < 0.5% from -20 to +50°C). Calibration certificate includes temperature dependency from -20 to +50°C in 8 steps..
CA-17/41
Sealed Gel Battery. Storage Capacity 263Ah, Output 12V. Dimensions: 521 x 269 x 203mm. Weight: 71Kg..
GMX531 Weather Station – Wind, Temp, RH, Pressure, Solar & Precipitation
The MaxiMet GMX531 is a combined instrument mounted inside three double louvered, naturally aspirated radiation shields for the measurement of wind speed and direction, ambient temperature, humidity, pressure, solar radiation and rainfall utilising an external tipping bucket rain gauge (included). The data is output in serial formats - RS232, RS485...
Load Cell Indicator N1500-LC
The N1500-LC is specifically designed for load cell and other weighing display applications. Featuring a smooth 10VDC supply for excitation of your load cells and simple programming allows easy integration. 30-points linearisation setting are available for non-linear outputs. The N1500-LC display features 2 SPDT relays and 4-20mA outputs with the..
Tinytag Thermistor Temperature Probes
A range of Tinytag thermistor probes for use with Tinytag data loggers. Designed to meet the demands of a wide variety of applications, this range of probes includes fast response probes for temperature profiling, surface probes for the recording of pipe work temperatures, armoured probes for use in meat processing..
0369700-004
CNF 4 Ventilation Unit. Specifically designed for the CNR 4 net radiometer to provide clean air-flow over all four domes and windows to minimise the formation of dew and reduce the frequency of dome cleaning. The built-in 10W heater will melt frost. Reduces frequency of dome cleaning. Minimises offsets and..
0369700-005
CNF 4 Ventilation Unit. Specifically designed for the CNR 4 net radiometer to provide clean air-flow over all four domes and windows to minimise the formation of dew and reduce the frequency of dome cleaning. The built-in 10W heater will melt frost. Reduces frequency of dome cleaning. Minimises offsets and..
0369900-034
CNR 4 Net Radiometer with 4 separate millivolt outputs for incoming and reflected short-wave radiation and downward and upward long-wave radiation. The unit consists of a pyranometer and pygeometer on both sides. Spectral range 300 to 2800nm (short-wave) and 4.5 to 42µm (long-wave), response time less than 18 sec (95%),..
0369900-035
CNR 4 Net Radiometer with 4 separate millivolt outputs for incoming and reflected short-wave radiation and downward and upward long-wave radiation. The unit consists of a pyranometer and pygeometer on both sides. Spectral range 300 to 2800nm (short-wave) and 4.5 to 42µm (long-wave), response time less than 18 sec (95%),..
0373900-001
PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 5m length...
0373900-003
PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 15m length...
GMX550 Weather Station – Wind, Temp, RH, Pressure & Precipitation
The MaxiMet GMX550 is a combined instrument mounted inside three double louvered, naturally aspirated radiation shields for the measurement of wind speed and direction, ambient temperature, humidity, pressure and rainfall utilising an external tipping bucket rain gauge (not included). The data is output in serial formats - RS232, RS485. SDI12,..
Tinytag PT100 Temperature Probes
A range of Tinytag PT100 Temperature Probes for use with Tinytag data loggers. Designed to meet the demands of a wide variety of applications with a wider temperature range than thermistor probes. This range of PT100 probes offer high temperature ranges with heavy duty over braided cable and oven probes...
Tinytag PT1000 Temperature Probes
A range of Tinytag PT1000 temperature probes for use with Tinytag data loggers. Designed to meet the demands of a wide variety of applications with a wider temperature range than thermistor probes. This range of probes includes high temperature probes with heavy duty over braided cable, oven probes and freezer..
0374900-104
SMP 3 Smart Pyranometer with 0-1vDC output. Single 4mm glass dome. Integrated leveling. Sun shield. Spectral range 300 - 2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2-wire RS485 Modbus and 0-1V output. Digital output range -200 to 2,000W/m². Analogue output range -200..
0374900-105
SMP 3 Smart Pyranometer with 0-1vDC output. Single 4mm glass dome. Integrated leveling. Sun shield. Spectral range 300 - 2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2-wire RS485 Modbus and 0-1V output. Digital output range -200 to 2,000W/m². Analogue output range -200..
0374900-204
SMP 3 Smart Pyranometer with 4-20mA output. Single 4mm glass dome. Integrated leveling. Sun shield. Spectral range 300 - 2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Digital output range -200 to 2,000W/m². Analogue output range..
0374900-205
SMP 3 Smart Pyranometer with 4-20mA output. Single 4mm glass dome. Integrated leveling. Sun shield. Spectral range 300 - 2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Digital output range -200 to 2,000W/m². Analogue output range..
Calibration Certificates for Tinytag Data Loggers
Omni Instruments can provide traceable calibration certificates for all of the Tinytag range of data loggers. We can provide initial calibrations on brand new devices and also a recalibration service for any Tinytag units returned to us. Standard calibration is done at temperatures of 0 and 30°C and humidity at..