GC62EX
GEN II Transmitter for direct connection to a U6-PULSE domestic gas meter. The GC62EX is designed to meet the requirements of IGEM / GM / 7A communications 1731 for connection to a domestic gas meter. The transmitter will accept up to 2 pulse inputs, max 250Hz and 65,000 per logging..
GD-67
GEN II radio transmitter for use with pulse outputs from flow, gas, energy or heat meters and any other devices with a pulse output. The transmitter will accept up to 7 pulse inputs, max 15Hz and 65,000 counts per logging period, counter resets for each transmission. Operating Range -30 to..
GD-68
GEN II radio transmitter for use with pulse outputs from flow, gas, energy or heat meters and any other devices with a pulse output. The transmitter will accept up to 8 pulse inputs, max 15Hz and 65,000 counts per logging period, counter resets for each transmission. Operating Range -30 to..
GD-81
GEN II radio transmitter with integrated barometric pressure sensor. Pressure Range 800-1100mBarA, Resolution 0.0122mBar/bit and Accuracy 1% FSS. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display...
GD-84
GEN II radio transmitter with integrated differential pressure transducer suitable for clean room applications. Differential Pressure Range -250 to +250Pa, Resolution 0.1Pa and Accuracy 3 Pa. Supplied with 4 x AA Alkaline batteries, stub antenna, integrated LCD display and 2 Cole Parmer quick connectors for 6mm I/D tubing...
GD900A
GEN II radio transmitter for direct connection to up to 6 ND Rail 350 power meter. Suitable for single of three phase energy meters with up to 11 parameters from all 6 meters, default settings are for 3 current phases, 3 power factors, 3 voltage, 1 kWh and 1 kVArH,..
GEN II Wireless Temperature and RH Monitoring System
The GENII wireless temperature and relative humidity monitoring system is able to cover a wide range of temperature and humidity monitoring applications. Transmitters are available with integrated temperature, temperature & RH sensors or with sockets for connecting thermistor, thermocouples and PT100 temperature sensors. A system can be customised to your..
GENII Transmitters
A wide range of transmitter units are available for V, mA, thermocouple, thermistor, and pulse inputs as well as units with integral temperature and humidity sensors. On the voltage and current (4-20mA) input a switched excitation O/P is available to power external sensors:..
GFT/1 1/2/BSP
1 1/2 inch Gas Flow Turbine 10 - 140 m3/Hr Stainless Steel Construction, Screwed Connections..
GFT/1/2HIGH/BSP
1/2 inch Gas Flow Turbine 0.5 - 7 m3/Hr. Stainless Steel Construction, BSP Screwed Connections..
GFT/1/BSP
1 inch Gas Flow Turbine 5 - 70 m3/Hr Stainless Steel Construction, Screwed Connections..
GFT/2/BSP
2 inch Gas Flow Turbine 18 - 252 m3/Hr Stainless Steel Construction, Screwed Connections..
GFT/3/4HIGH/BSP
3/4 inch Gas Flow Turbine 2.5 - 35 m3/Hr. Stainless Steel Construction, BSP Screwed Connections..
GFT/3/4LOW/BSP
1/2 inch Gas Flow Turbine 1 - 14 m3/Hr. Stainless Steel Construction, BSP Screwed Connections..
GFT/4-20mA
Alternative 4-20mA output option..
GFT/IS
Intrinsically safe pick-up option. Suitable for Hazardous Installations ( Eex ia IIC T4 ) ...
GL7000 Modular Data Acquisition Unit
The GL7000 is a high speed modular data acquisition unit that can be built up to fit a variety of different applications with a selection of different modules available to provide voltage, temperature or digital inputs along with voltage and alarm outputs. A total of 10 modules can be added..
GL220 Data Logger Hire
The GL220 is the next generation midi logger following on from the success of the GL200 & GL200A models. With 10 fully isolated multi-function inputs, large internal 2GB Flash memory and a port for an external USB stick memory, this logger has significantly more memory than it predecessors. The USB..
GL220-HIRE
GL220 data logger with built-in 4.3" WQVGA TFT LCD Color Display. 10 analog measurement channels, 20mV to 50V, Thermocouples: Type K, J, E, T, R, S, B, N, W. Sampling rate: Max 10ms (1 Channel), 100ms (10 Channels & Thermocouples). 2GB internal flash memory with separate port for USB flash..
GPS16-HVS
GPS 16 HVS GPS receiver, with RS232 O/P, power supply 6-40 vDc, consumption 65mA at 12v Dc, Baud rates: 300 / 600 / 1200 / 2400 / 4800 / 9600 / 19200. Receiver: WAAS-enabled; 12 parallel channel GPS receiver continuously tracks and uses up to 12 satellites to compute and..
GPSCOVERT
GPS covert waterproof antenna with 5m RG174 cable, SMA plug. Covert GPS Antenna with Sticky Pad Adhesive. Ideal for Covert use on vehicles (Fully Waterproof). Dimensions: Width 27mm, Height 10mm...
GRD1000-XF
GRD1000-XF GSM/GPRS modem with an RS232/485 serial port. Can be used to connect any serial device to a remote server running the Middleware software via GPRS. Power supply 9-30vDC. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface can..
GRD1300-XF
GRD1300-XF GSM/GPRS data logger and SMS alarm unit with an RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface..
GRD1530-XF
GRD1530-XF GSM/GPRS data logger and SMS alarm unit with two RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface..