2279 AC/DC Transmitter
The 2279 AC/DC Transmitter is suitable for measuring AC voltage in the range of 0.5 to 250 VRMS sinusoidal voltages and current measurements up to 1 ARMS with a direct connection to the unit and higher current ranges with an external shunt. Standard analogue outputs are selectable using DIP Switches..
2279–D
2279 AC/DC Transmitter. Supply voltage 24vDC and DIP Switch selectable output options of 0-1 & 0-10vDC or 0-20 & 4-20mA. Input ranges programmed using DIP Switches and jumpers to switch between current and voltage measurement ranges. Standard 11-pole relay socket connection...
2279–P
2279 AC/DC Transmitter. Universal power supply 21.6-253vAC or 19.2-300vDC with DIP Switch selectable output options of 0-1 & 0-10vDC or 0-20 & 4-20mA. Input ranges programmed using DIP Switches and jumpers to switch between current and voltage measurement ranges. Standard 11-pole relay socket connection. Unit has 3-port galvanic separation...
2284 Isolation Amplifier
Galvanically separated input, output, and supply ~ Bipolar current / voltage input Signal conversion ~ Current and voltage output 24 VDC or universally supplied Applicable in PELV/SELV circuits..
2284–D2
Isolation Amplifier, V OUt Put, Isolated Input / Output / Supply, 24 VDC..
2284–P2
Isolation Amplifier, V Output, Isolated Input / Output / Supply, 24...230 VAC/DC..
2284-D1
Isolation Amplifier, I/V Output, Isolated Input / Output / Supply 24 VDC..
2284P1
Isolation Amplifier, I/V Output, Isolated Input / Output / Supply, 24...230 VAC/DC..
Keller EXd Pressure Transmitters for Hazardous Applications, Series 23 ED / 25
These Keller pressure transmitters are approved for use in high explosion risk areas and are ATEX approved certified EXD. They provide stable and accurate measurements of absolute and gauge pressures of liquid and gaseous media in the pressure range between 200mBar and 300 Bar. Available with standard 1/4" BSP male..
242428-1313
POLILYTE Plus ARC pH sensor. Power supply, 7-30vDC, measuring range 0 to 14 pH with zero point +/-20mV at 25 C (factory calibration). Each sensor provides two programmable 4-20mA output for pH and temperature plus RS485 Modbus RTU output via VP 8.0 socket head. Glass shaft with Viton seals and..
242428-1323
POLILYTE Plus ARC pH sensor. Power supply, 7-30vDC, measuring range 0 to 14 pH with zero point +/-20mV at 25 C (factory calibration). Each sensor provides two programmable 4-20mA output for pH and temperature plus RS485 Modbus RTU output via VP 8.0 socket head. Glass shaft with Viton seals and..
242428-1333
POLILYTE Plus ARC pH sensor. Power supply, 7-30vDC, measuring range 0 to 14 pH with zero point +/-20mV at 25 C (factory calibration). Each sensor provides two programmable 4-20mA output for pH and temperature plus RS485 Modbus RTU output via VP 8.0 socket head. Glass shaft with Viton seals and..
TGU-4550-SPK
Tinytag TGU-4550-SPK Thermocouple data logger starter pack. Supports K, J, T and N Type thermocouples, 28,000 reading memory, internal sensor for ambient temperature and port for external thermocouple. External K type thermocouple (temperature range -100 to +250°C) included with the unit and others available separately. Kit comes complete with Tinytag..
2643853
XR 13 pack of 5 fibre pens, Red long, for channel 2 of BD 12 / 12E..
2643858
XR 13 pack of 5 fibre pens, Black long, for channel 2 of BD 12 / 12E..
2643908
XR 12 pack of 5 fibre pens, Black short..
2643909
XR 12 pack of 5 fibre pens, Red short..
2643918
XR 9 10 rolls of chart paper, length 25 m, zero left..
2643962
XR 18 10 rolls of chart paper, length 25 m, zero right..
2914 2-Wire Room Temperature Transmitter
Wall-mounted room temperature transmitter. The unit comes complete with PT100 sensor and 4-20mA output transmitter via a 2-wire connection. Easily mounted and suitable for a temperature range 0-70C and a power supply 8-35vDC...
294-900
Thermadata Stainless Steel Data Logger with Integrated Temperature Sensor. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable and ThermaData Studio..
294-930
Thermadata Stainless Steel Data Logger with Ø3.3 x 50mm Penetration Temperature Probe. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable..
294-931
Thermadata Stainless Steel Data Logger with Ø4.5 x 100mm Penetration Temperature Probe. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable..
294-932
Thermadata Stainless Steel Data Logger with Ø4.5 x 150mm Penetration Temperature Probe. Temperature Range: -20 to +125°C. Memory 16,000 readings. Logging rate from 1 to 255 minutes with delayed start and individual 12 character ID. 3.6V 2/3 AA Lithium Battery provides 3 years operation. Loggers are supplied with USB cable..