18106831
Nylon Carrying Case suitable for MX6 without pump...
18106856-1
Hard Leather Case without window for diffusion MX6..
18106864
Nylon carrying case for aspirated MX6...
0359900-022
CGR 4 Pyrgeometer with integrated PT100 temperature sensor. Silicon meniscus dome with hard carbon coating and infrared window materials to absorb short-wave radiation. Integrated leveling. Sun shield. Spectral range 4500-42,000nm, response time less than 18 sec (95%), temperature dependence of sensitivity less than 1% (-20 to +50°C). Operating temperature -40..
0362920-022
CMP 21 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². PT100 output. Supplied with waterproof 8-pin plug connector with 10m of pre-wired yellow..
0362930-022
CMP 22 Secondary Standard Pyranometer. Two, 4mm thick, very high quality quartz domes. Integrated leveling. Sun shield. Spectral range 200-3600nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². PT100 temperature output. Supplied with waterproof 8-pin plug connector with 10m of..
0374900-202
SMP 3 Smart Pyranometer with 4-20mA output. Single 4mm glass dome. Integrated leveling. Sun shield. Spectral range 300 - 2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Digital output range -200 to 2,000W/m². Analogue output range..
0374905-202
SMP 10 Smart Pyranometer with 4-20mA output. Double 2mm glass dome. Integrated leveling. Sun shield. Spectral range 285 - 2800nm, response time less than 2 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Analogue output range 0 to 1600Wm², Digital output range..
0374920-202
SMP 6 Smart Pyranometer with 4-20mA output. Two, 2mm thick, high quality concentric domes. Integrated levelling. Sun shield. Spectral range 285-2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Analogue output range 0 to 1,600Wm², Digital output..
0374940-202
SMP22 Smart Pyranometer with a configurable 4-20mA output. Secondary standard pyranometer with a 32-junction thermopile sensing element under two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 250 - 3500nm, response time less than 2 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire..
0376900-202
SGR4-A Smart Pyrgeometer. Silicon meniscus dome with hard carbon coating and infrared window materials to absorb short-wave radiation. Integrated leveling. Sun shield. Spectral range 4400-50,000nm, response time less than 18 sec (95%), temperature dependence of sensitivity less than 1% (-20 to +50°C). Operating temperature -40 to +80°C. 2-wire RS485 Modbus..
1-Wire Dual Channel Analogue Modules
1-Wire Dual-Channel Analogue Input Modules covering 0-20mA, 0-10V and 0-60V signals inputs with screwless terminal connections. The TSA202 is a dual-channel module for 0-20mA and 0-10V inputs, converting analogue current signals from industrial sensors into digital data. In contrast, the TSA202-60 is a dual-channel module suitable for 0-60V inputs. Both..
18106880-1
Hard leather case without window for aspirated MX6...
1957-0500-60-101
MaxiMet GMX500 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and Direction correcting for..
1957-0501-60-101
MaxiMet GMX501 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and Direction..
1957-0531-60-101
MaxiMet GMX531 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Rainfall, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and..
1957-0550-60-101
MaxiMet GMX550 Compact Weather Station with GPS & Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill,..
1957-0551-60-101
MaxiMet GMX551 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Pulse Input for Rainfall, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True..
1957-0560-60-101
MaxiMet Marine GMX560 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, 6-Axis Compass Heading, GPS Location, Heading and Speed. Compass allows compensations for tilt and provides pitch & roll data. Derived Parameters: Average Wind Speed & Direction, Corrected..
1957-0600-60-101
MaxiMet GMX600 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Precipitation, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and Direction correcting..
20/20MI-32SF
20/20MI Sharpeye Mini Short Range IR3 Flame Detector with connector output. Sensitive Range: 2.5 to 10m. Field of View: 100° Horizontal & 100° Vertical. Response Time: 5 seconds, adjustable up to 30 seconds. Automatic and Manual Built-In-Test. Output: Relays (SPST 30vDC @ 2A), 4-20mA (Fault = 0mA; BIT Fault =..
3117
PR3117 Slim Series Bipolar Isolated Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of bipolar inputs to unipolar outputs. Input options of 10mA, 20 mA, 5V or 10V with unipolar mA or V outputs. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply:..
3186B2
3186B2 Dual Channel 2-Wire Current Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of active current input signals within the range 3.8-20.5 mA, Response time: less than 5 ms, Accuracy 0.05% of span. Loop powered via the output loop, voltage drop <3V with a 10uA..
420.0210
ThermoAir Pro Omnidirectional (MA) Thermal-Electric Omnidirectional Anemometer. Air Velocity Range: 0.015-1m/s with a 4-20mA Output. Accuracy ±1.0% of full scale. Sensing head surrounded by a removable 110mm diameter protective cage, handle 15mm diameter, probe length 270mm. The probe measures the flow velocity from all directions in the measuring plane perpendicular..