88-PRO
LCD display, 3 1/2 digit, 12.7mm digits, loop powered, 4-20mA, voltage drop 2.5 volts, scaling by zero and span poteniometers. Dimensions 48 x 96mm...
8801801005
WL420 Submersible Hydrostatic Level Transmitter. Depth Range 1mH2O. 2-Wire Loop Powered 4-20mA Output with a 12-36vDC Power Supply. 5m Polyurethane (PUR) Cable with Ventilation Tube. Over-Pressure 300% FS, Burst Pressure 600% FS. Stainless Steel Sensor with 105mm Body Length and 26.5mm Diameter...
8802100120
TL400-V Non-Intrusive Laser Level Sensor. Suitable for tank level monitoring of liquids, grains or solids. Measuring Range: Up to 4m. Output Signal: 0.5-4.5V, Accuracy: up to 2mm. 3-pin Superseal Connector with 150mm cable. Interface: Mobile Device + SigNow Mobile App (Android and iOS). Power Supply: 8 to 33vDC. Consumption: 70mA..
8803006430
RHT-WM-485-LCD Wall mounted Humidity and Temperature transmitter with integrated LCD Display...
8803006706
RHT-WM Wall Mount Temperature & Humidity Transmitter with a programmable 4-20mA output. Full programmable range: -40 to +120°C, Operational Range: -10 to +65°C. 12-30vDC loop power supply...
8804400110
RHT-AIR Wireless Temperature and Relative Humidity Transmitter. Temperature Range -40 to +100°C, Relative Humidity Range 0 to 100%RH. Power Supply Internal battery or 12 to 32vDC. Micro USB port for configuration via DigiConfig software. Operating Range, -10 to +70°C and 0 to 95%RH...
8811612420
DigiRail Connect DMIX Ethernet I/O Module. 8 Digital Inputs: High Logic Level (1): >2.2V, Low Logic Level (0): <1.5V; Pulse Counter; Digital State (NPN, PNP or dry contact). 8 Transistor Sourcing Digital Outputs, Actuation Modes:: Logical State; Pulse Duration; or Pulse Train. Power Supply 10-36vDC. Modules are DIN Rail mountable..
8812120000
FieldLogger data logger with 512k internal memory. 8 Universal Inputs, 2 Relay Outputs, 8 Digital I/O's and Mini USB Interface for PC Interface for programming, monitoring and downloading. Power Supply: 100-240vAC, with 24vDC auxiliary supply for connected devices. Complete model, with Ethernet, USB host for data downloading to USB memory..
8816001039
USB-i485 USB Converter to dual RS485 Isolated ports..
8818040031
FTR DIN Rail Transmitter Power Supply. Input 100-240vAC, Output 24vDC at 3W, 600V Isolation. IP40 grey polymide enclosure suitable for connection to a 35mm DIN Rail...
8830007000
PT100 temperature sensor with a 6mm diameter 316 Stainless Steel probe with 50mm probe length and ½" BSP thread connection. Suitable for temperatures from -50 up to 300°C. Transmitter housing suitable for any standard head mounted transmitter. Cable gland access for remote connection..
9106A1A
Single channel isolated HART transparent repeater, 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508..
9106B1A
Single channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508..
9107AA
PR 9107AA Single Channel HART Transparent Driver. Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus ATEX, IECEx, FM, INMETRO, CCC and EAC-Ex Approvals. Power Supply: 19.2-31.2vDC, via..
9107BA
PR 9107BA Intrinsically Safe Single Channel HART Transparent Driver. Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area, or in Zone 2/Class I, Division 2 and transmit signals to Zone 1 0, 1, 2 and Zone 20, 21, 22, including mining/Class I/II/III, Div 1,..
9113BA
Temperature & mA Converter for hazardous areas. Single channel unit with active or passive mA outputs. Suitable for RTD, TC and mA inputs and SIL-2 certified....
9116B1
9116B1 Universal Converter IS Interface 4-20mA and Relay outputs. Max loop voltage <28vDC. Input Pt100, Pt1000, Ni100, TC types, RTD types, Potentiometer, Linear resistance, NAMUR, 0...12 VDC. Output 0-20 mA, 4-20 mA, 20-0 mA, 20-4 mA, Relay(s), 2-wire 4-20 mA..
9202A1A
Pulse isolator, 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. With cable fault check (LFD) function...
9202B1A
Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply...
9203A1A
Solenoid and alarm driver, 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
9203B1A
Solenoid and alarm driver, ATEX approved 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
93.0406
Meteo anemometer and wind vane for windspeed & direction. Velocity measurements obtained via a cup star anemometer probe providing readings from 2.5 to 210km/h, output 0 - 2.1V (1V = 100km/h). Direction measurements obtained via a windflag providing readings from 0 - 360°, output 0 - 1vDC. Operating range -30°C..
93.0554
Meteorological Sensor with cup anemometer and wind vane for windspeed and direction monitoring. Wind Speed 0.7-40m/s, accuracy 0.3m/s (2% of reading). Wind Direction 0-360°, linearity ±0.5°, deadband 3°, ±1°. 2 x 4-20mA outputs for Wind Speed and Direction. Power Supply 9-26vDC. Material operating temperature -30 to +65°C. Type f.566.24.28..
95.0146
Meteo anemometer self-powered rotating cup anemometer for wind speed. Air velocity range 2.5 - 210Km/h , accuracy ±0.3m/s, ±5% of reading, output 0-2.1vDC (1V = 100Km/h). This product does not include an indicator...