BM25 Replacement Sensor Cells

The BM25 gas detectors include field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration. Up to 5 sensor can be installed, each in one or more specific location.

Need help finding the right product?

Description

Sensor Configuration

The sensors are located on the front of the monitor. They are smart, pre-calibrated from factory and interchangeable. They are composed of a sensitive element and electrical components, including an EEPROM memory in which the sensor characteristics are stored (gas type, range, span value, instantaneous, STEL and TWA alarm values, date of manufacture, serial number, date of last calibration, span reserve, etc.). The span reserve is updated after each calibration and allows the user to gage the optimal time for changing the sensor.

Click the Part Numbers below for more detail and to purchase the desired cells

Click Part Number

for More Details

Gas Measurement  Location
Range Resolution
LEL Catalytic Bead Sensor
6313969 CH4, Methane 0-100% LEL, for BM 25A only. Retrofit required for BM25’s 0-100% LEL 1%LEL 1 Only
6313888 Combustible Gas (Default CH4) Contact us for more information. 0-100% LEL 1%LEL 1 Only
Electrochemical Sensor
6313811 Arsine (AsH3) 0 to 1ppm 0.01ppm 2 or 3
6313809 Chlorine (Cl2) Mini 0 to 10ppm 0.1ppm 2 or 3
6313843 Chlorine (Cl2) Medium 0 to 10ppm 0.1ppm 4 or 5
6313841 Chlorine Dioxide (ClO2) 0 to3ppm 0.01ppm 2 or 3
6313787 Carbon Monoxide (CO) 0 to 1,000ppm 1ppm 2 or 3
6313826 Carbon Monoxide, High (CO) 0 to 2,000ppm 1ppm 2 or 3
6313241S Carbon Monoxide, Null H2 (CO) 0 to 500ppm 1ppm 2 or 3
6313823 Carbon Monoxide/ 0 to 1,000ppm 1ppm 4 or 5
Hydrogen Sulphide (CO/H2S) 0 to 100ppm 1ppm
6313812 Phosgen (COCl2) 0 to 1ppm 0.01ppm 2 or 3
6313821 Ethylene Oxide (C2H4O) 0 to 30ppm 0.1ppm 4 or 5
6313820 Fluor (F2) 0 to 1ppm 0.01ppm 2 or 3
6313803 Hydrogen (H2) 0 to 2,000ppm 1ppm 2 or 3
6313788 Hydrogen Sulphide (H2S) 0 to 100ppm 1ppm 2 or 3
6314240S Hydrogen Sulphide, Null CO (H2S) 0 to 100ppm 1ppm 2 or 3
6313804 Hydrogen Chloride (HCl) 0 to 30ppm 0.1ppm 2 or 3
6313805 Hydrogen Cyanide (HCN) 0 to 30ppm 0.1ppm 2 or 3
6313806 Hydrogen Fluoride (HF) 0 to 10ppm 0.1ppm 2 or 3
6314276 Hydrazine (N2H4) 0 to 1ppm 0.01ppm 2 or 3
6313799 Ammonia (NH3) 0 to 100ppm 1ppm 2 or 3
6313800 Ammonia (NH3) 0 to 1,000ppm 1ppm 2 or 3
6313802 Nitrogen Oxide (NO) Mini 0 to 300ppm 1ppm 2 or 3
6313856 Nitrogen Oxide (NO) Medium 0 to 300ppm 1ppm 4 or 5
6313801 Nitrogen Dioxide (NO2) Mini 0 to 30ppm  0.1ppm 2 or 3
6313857 Nitrogen Dioxide (NO2) Medium 0 to 30ppm  0.1ppm 4 or 5
6313780 Oxygen (O2) Medium 0-30% Vol  0.1%Vol 4 or 5
6313817 Oxygen (O2) Mini 0-30% Vol  0.1%Vol 2 or 3
6313807 Ozone (O3) 0 to 1ppm  0.01ppm 2 or 3
6313810 Phosphine (PH3) 0 to 1ppm  0.01ppm 2 or 3
6313808 Silane (SiH4) 0 to 50ppm  0.1ppm 2 or 3
6313819 Sulphur Dioxide (SO2) 0 to 30ppm  0.1ppm 4 or 5
6313822 Sulphur Dioxide (SO2) 0 to 100ppm  0.1ppm 4 or 5
6313998 Photo-Ionisation Detector (PID) 0 to 1,500ppm 1ppm 5 Only
Infrared Sensors
6313818 Carbon Dioxide (CO2) 0-5% Vol  0.1% Vol 4 or 5
6314064 Methane (CH4) 0-5% Vol 0-100% LEL 1%LEL 5 Only
6314065 Methane (CH4) 0.4.4% Vol 0-100% LEL 1%LEL 5 Only
6314092 Methane (CH4) 0-100% Vol 0-100% Vol 1%Vol 5 Only
6314087 Propane (C3H8) 0-100% LEL 1%LEL 5 Only
6314088 Butane (C4H10) 0-100% LEL 1%LEL 5 Only
6314090 Liquid Petroleum Gas (LPG) 0-100% LEL 1%LEL 5 Only
6314091 Ethanol (C2H6O) 0-100% LEL 1%LEL 5 Only

Teflon lined tubing should be used when sampling for the following gases: Ammonia (NH3), Chlorine (Cl2), Chlorine Dioxide (ClO2), Hydrogen Chloride (HCl), Hydrogen Cyanide (HCN), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Phosphine (PH3), Sulphur Dioxide (SO2), or Photo Ionization Detectors (PIDs) used to detect volatile organic compounds (VOCs) including Benzene (C6H6). This tubing should also be used with any unknown gases. Urethane tubing is also available for common gases not previously mentioned.

NB. Adding a sensor to location 5 will deactivate the sensor in location 2.