Description
Applications
- The device can be mounted in the safe area and in zone 2 / div. 2 and receive signals from zone 0, 1, 2, 20, 21 and 22 / Class I/II/III, Div. 1, Gr. A-G.
- Conversion and scaling of temperature (Pt, Ni and TC) and active current signals.
- Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail.
- The 9113 has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Features
- Input for RTD, TC and mA
- Active / passive mA output
- 1 or 2 channels
- Can be supplied separately or installed on power rail, PR type 9400
- SIL 2-certified via Full Assessment
PR 4510 Display / programming front
Application:
- Communications interface for modification of operational parameters in 9116.
- Can be moved from one 9116 module to another and download the configuration of the first converter to subsequent converters.
- Fixed display for readout of process data and status
Technical characteristics:
- LCD display with 4 lines; line 1 (H = 5.57 mm) shows input signal, line 2 (H = 3.33 mm) shows units. Line 3 alternates between digital output value and scaling (kHz, Hz, mHz, P/m, P/h, P/d) or shows TAG no. Line 4 shows tendency readout for the input signal and communication status.
- Programming access can be blocked by assigning a password. The password is saved in the converter in order to ensure a high degree of protection against unauthorised modifications to the configuration.
Options
Type | Channels |
9113B | A: Single Channel B: Dual Channel |
If required, Omni Instruments will program a 9113B to your specific requirements. Please contact us for details.