PB-5019-3M
Flat Cable Thermistor Probe for use with Tinytag data loggers. 10K NTC Thermistor, Range -40 to 125°C. The stainless steel probe is 50mm long and 6mm in diameter with a 3m cable. IP66 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy connector...
AKF398
3 Axis MEMS Accelerometer with a 4-20mA current output. 4-20mA outputs for X, Y and Z axis. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C...
AMS-DIG8
8 Channel extension for the AMS LAN all-in-one Data Aquisition Units. Provides an additional 8 digital channels through 8 galvanically isolated optocoupler inputs and relay outputs. The AMS-DIG8 is installed on to a new AMS42 via an additional backplane and is only available when purchased with a new AMS42 System...
AMS-HANDLE
Practical carrying handle for AMS all-in-one Data Aquisition Units...
AMS-HANDLE2
Two metal carry handles for AMS all-in-one Data Aquisition Units. Suitable for the following amplifier measurement systems: AMS42/AMS84, AMS42-LAN16F/AMS84-LAN16F, and AMS42-USB/AMS84-USB...
AMS-K-BIN5
AMS-K Series Cassettes for 5B Modules. Cassettes have a 5-pin Binder socket (712 series). Suitable 5B Modules are available separately...
AMS-K-BLANK
Blank AMS-K Series Cassettes. Protects the AMS units from external influences...
AMS-K-BNC
AMS-K Series Cassettes for 5B Modules. Cassettes have a BNC female connection, allowing a Hi and low signal suitable for using 2-way sensors. 5B Modules are available separately...
AMS-K-CO5
AMS-K Series Cassettes for 5B Modules. Cassettes have a 5-pin socket for connecting a 5-pin screw type terminal block (ZU5STL). 5B Modules are available separately...
AMS-K-THK
AMS-K Series Cassettes for 5B Modules. Cassettes have a K Type thermocouple socket for temperature measurement inputs. Suitable 5B Modules are available separately...
AMS42-EXT8
8 Channel extension for the AMS42 all-in-one Data Acquisition Units. Provides an additional 8 analogue channels for fitting AMS-K cassettes and 5B modules. The AMS42-EXT8 is installed on to a new AMS42 via an additional backplane and is only available when purchased with a new AMS42 System. AMS-K cassettes and..
AMS42-LAN16FX
AMS42-LAN16fx All-In-One Measurement System. 8 Amplifier Inputs via AMS-K Cassettes and 5B Amplifiers with 16-Bit Resolution and 250kHz Total Sampling Rate. A further 8 Analogue Inputs and 2 Analogue Outputs are available via 37-pin Sub-D Connector. 32 Digital Input/Outputs, plus Three 32-Bit Counter Input. Power Supply 9-40vDC, (max 20W, depending..
AMS42-USB
AMS42-USB All-In-One Measurement System. 8 Amplifier Inputs via AMS-K Cassettes and 5B Amplifiers with 16-Bit Resolution and 250kHz Total Sampling Rate. A further 8 Analogue Inputs and 2 Analogue Outputs are available via 37-pin Sub-D Connector. 32 Digital Input/Outputs, plus Three 32-Bit Counter Input. Power Supply 9-40vDC, (max 20W, depending..
AMS84-LAN16FX
AMS84-LAN16fx All-In-One Measurement System. 16 Amplifier Inputs via AMS-K Cassettes and 5B Amplifiers with 16-Bit Resolution and 250kHz Total Sampling Rate. 2 Analogue Outputs are available via 37-pin Sub-D Connector. 32 Digital Input/Outputs, plus One 32-Bit Counter Input. Power Supply 12-40vDC, (max 20W, depending on number of 5B modules used)...
AMS84-USB
AMS84-USB All-In-One Measurement System. 16 Amplifier Inputs via AMS-K Cassettes and 5B Amplifiers with 16-Bit Resolution and 250kHz Total Sampling Rate. 2 Analogue Outputs are available via 37-pin Sub-D Connector. 32 Digital Input/Outputs, plus One 32-Bit Counter Input. Power Supply 9-40vDC, (max 20W, depending on number of 5B modules used)...
ANTCFD890EL
Dipole Antenna, 2dBi gain, 5m cable. Suitable for the 868MHz Frequency range...
AP2A
Mounting backplane for up to 2 5B series amplifiers. Power supply 9-40vDC or +5vDC ( max 1.5 amps )...
AP8A
Mounting backplane for up to 8 5B series amplifiers. Power supply 9-40vDC or +5vDC ( max 1.5 amps )...
GS-3AT
GS-3AT Acceleration and temperature sensor. Acceleration, in 3-axes, range max 10g. Temperature -10 to 50°C. The sensor can provide Peak (largest value each interval), average (mean value during interval) and RMS (root mean square value) acceleration readings at set sampling rates of 500ms up to 60 mins (Sub-sampling interval is..
OceanDISP-1K
OceanDISP-1K subsea LED display unit suitable for displaying sensor readings from Datataker DT80 and DT85 data loggers. Light activated scrolling display with programmable scroll interval. Suitable for depths up to 1,000m..
APS-SERIES-AP
APS Series Autopilot Platform :size (2.63 inch W x 2.10 inch H x 2.63 inch D) , 30 fully programmable digital I/O lines , 4 RS-232, full duplex UARTS , PWM inputs and outputs for servo control , 12 Analog inputs (12 bit) , 5 VDC supply for analog, Hall-effect,..
APS21024
Microbot APS Development Kit complete with autopliot programming dongle, second ( ground station radio modem ) and antennas...
APSN
Air purge collar for PyroMini -151, -201, -301 and CF models. The air purge collar is used to keep dust, fumes, moisture, and other contaminants away from the lens. It must be screwed fully onto the sensing head. Air flows into the 1/8 BSP fitting and out of the front..
APSW
Air purge collar for PyroMini -21 models. The air purge collar is used to keep dust, fumes, moisture, and other contaminants away from the lens. It must be screwed fully onto the sensing head. Air flows into the 1/8 BSP fitting and out of the front aperture. Air flow should..