Description
The TGU-4550 Tinytag Ultra 2 data loggers are ideally suited to monitor temperatures using an external thermocouple temperature sensor. The Tinytag Ultra 2 Thermocouple logger supports four different types of thermocouple sensor (Type-K, J, T & N) and is compatible with both standard and miniature thermocouple plugs. The TGU-4550’s are ideal for monitoring temperatures in applications with extreme high or low temperatures, covering everything from kiln temperatures or cryogenic applications. The logger also allows for ambient temperatures to be monitored with an internal sensor, which can be disabled to allow more readings from the external probe
Features
- Temperature Range:
- Type K -270 to +1370°C (-454 to 2498°F);
- Type J -210 to +1200°C (-346 to 2192°F);
- Type T -270 to +400°C (-454 to 752°F)
- Type N -270 to +1300°C (-454 to 2372°F).
- Internal Temperature Sensor (can be turned off)
- Internal memory for up to 22,000 readings
- Logging rates from 1 sec up to 10 days.
- 4 user programmable alarms
- Delayed start option (up to 3650 days)
- Triggered start option
- IP51 casing with mounting hole
- Compatible with standard and miniature thermocouple plugs.
- User replaceable battery
Popular Applications
- Aluminium smelting
- Concrete Curing
- Kiln Temperature Monitoring
- Laboratory temperature monitoring
- Cryogenic Temperature monitoring
- Engine exhaust temperatures
Physical Specifications | External Sensor | ||
Total Reading Capacity: | 22,000 Readings | Sensor Type: | External Type K, J, T or N Thermocouple |
Memory Type: | Non-Volatile | Measuring Range: | Type K -270 to +1370°C (-454 to 2498°F) Type J -210 to +1200°C (-346 to 2192°F) Type T -270 to +400°C (-454 to 752°F) Type N -270 to +1300°C (-454 to 2372°F) |
Trigger Start: | Magnetic Switch | ||
Delayed Start: | Relative/Absolute (up to 3,650 days) | Reading Resolution: | 0.01°C |
Stop Options: | When full Never (overwrite oldest data) |
Cold Junction Compensation: | -10 & +70°C. |
Reading Types: | Actual, Min, Max | Accuracy: | Better than ±1.0°C across all thermocouple ranges when the logger is between -10 & +70°C. |
Logging Interval: | 1 sec to 10 days | Internal Sensor | |
Alarms: | 4 fully programmable; latchable | Measuring Range: | -40 to +85°C (-40 to +185°F) |
Operational Temperature Rating: | -40 to +85°C (-40 to +185°F) | Sensor Type: | Internal 10K NTC Thermistor |
IP Rating: | IP51 | Response Time: | 20 mins to 90% FSD in moving air |
Case Dimension (HxWxD): | 72 x 60 x 33mm | Reading Resolution: | 0.02°C or better |
Weight: | 65g | Accuracy: | Better than ±0.5°C |
The TGU-4550 can be downloaded using the USB cable, Ref CAB-0007-USB. The download cable connects to the base of the logger and allows for configuration and downloading data.