PR 5337 2-Wire Transmitter with HART 7 Protocol
The PR 5337 is a universal 2-wire temperature transmitter that combines exceptional versatility with the latest HART communication technology. It converts a wide range of inputs—including RTD, thermocouple, linear resistance, and bipolar mV signals—into a standard 4-20mA output. Its key differentiator is the user-selectable HART protocol, allowing it to operate..
PR 5343 2-Wire Programmable Level Transmitter
The PR 5343 is a 2-wire transmitter designed for highly accurate resistance measurement, a function that makes it a dedicated level transmitter. It is a cost-effective solution for converting linear or non-linear resistance variations into a standard 4-20mA output. Its core applications involve measuring..
5437A1SM
PR 5437A1SM 2-Wire Programmable Transmitters with HART 5/7 Protocol. Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer..
5437A2SM
PR 5437A2SM 2-Wire Programmable Transmitters with HART 5/7 Protocol. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to..
5437B1SM
PR 5437B1SM 2-Wire Programmable Transmitters with HART 5/7 Protocol. Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer..
5437D1SM
PR 5437D1SM 2-Wire Programmable Transmitters with HART 5/7 Protocol. Single Channel Input: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ..
5437D2SM
PR 5437D2SM 2-Wire Programmable Transmitters with HART 5/7 Protocol. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to..
PR 5437 2-Wire HART 7 Temperature Transmitter
The PR 5437 is a high-end, 2-wire universal HART temperature transmitter designed for the most critical and demanding applications. It sets itself apart with a "true dual input" design, featuring a high-density 7-terminal configuration that allows it to accept a wide variety of sensor combinations, including..
PR 5450 Profibus PA Transmitter
The PR 5450 is a high-performance PROFIBUS PA temperature transmitter designed for demanding industrial environments. It provides universal input capability for a wide range of RTD, thermocouple, mV, and resistance sensors, making it an extremely versatile and valuable asset for digital bus networks. A key feature is its true dual-input..
5450A1
PR 5450A1 2-Wire Programmable Profibus PA Transmitters. Single Channel Input: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer..
5450A2
PR 5450A2 2-Wire Programmable Profibus PA Transmitters. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or..
5450B1
PR 5450B1 2-Wire Programmable Profibus PA Transmitters. Single Channel Input: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer..
5450B2
PR 5450B2 2-Wire Programmable Profibus PA Transmitters. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or..
5450D1
PR 5450D1 2-Wire Programmable Profibus PA Transmitters. Single Channel Input: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer..
5450D2
PR 5450D2 2-Wire Programmable Profibus PA Transmitters. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or..
5400-S-DG
Drill guide for 5400 and 6400 series meters, 2 and 2.5 inch..
5400-U-DG
Drill guide for all 5400 and 6400 series meters up to 6 inch..
59070-1-S-02-A
50970 Series Magnetic Reed Switch. M8 x 1.25 mounting thread with 2 retaining nuts for easy mounting, 38.1mm long. Normally Open. Max switching: 200vDC, 0.5A or 10 Watts. Pull-in range 12-18mm, activate distance 9mm. 300mm Tinned leads...
59070-4-S-02-A
50970 Series Magnetic Reed Switch. M8 x 1.25 mounting thread with 2 retaining nuts for easy mounting, 38.1mm long. Normally Closed. Max switching: 175vDC, 0.25A or 5 Watts. Pull-in range 15-20mm, activate distance 7.5mm. 300mm Tinned leads...
5B Measuring Amplifiers (MA Series)
The 5B measuring amplifiers allow for the signal conditioning of inputs into the cassette slots on the AMS42 and AMS84 All-in-one measurement system. Multi-range amplifiers (covering voltage, current, resistance, PT100, strain gauge, thermocouple and LVDT inputs), as well as modules with specific functionality (e.g. filter modules, frequency voltage converters, pulse..
1400 Peli Case
The 1400 Peli case is a small-medium protective carry case which is IP67 rated and can be supplied with the Pick N Pluck foam insert. Cases are available in black, orange or yellow with standard interior dimensions of 306L x 234W x 130H. The 1400 is suitable for use with..
2000-FSCEIN
AP-2000 Fluorescein Dye Optical Electrode with 2 Auto-Range scales 0-99.99µg/L or 100-500µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L...
5000-FSCEIN
AP-5000 Fluorescein Dye Optical Electrode with 2 Auto-Range scales 0-99.99µg/L or 100-500µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L...
5114B3B
Programmable Transmitter, Channel 1, ATEX II (1) GD, RTD, TC, mV, R, 24...230 VAC/DC..