5106BB-B
Hart Transparent Repeater, 2 Channel, ATEX II (1) GD, 4...20mA, 24...230 VAC/DC..
5115B2
5115B2 Ex Signal Calculator. Redundancy measurement of 2 inputs, duplication of input signals or signal calculations of inputs. Unit will accept mA, V or mV input signals. Power supply 21.6 - 253 vAC or 19.2 - 300vDC with 0-20mA or 0-10vDC output...
6513566
OLC10 TWIN fixed gas detector with Wheatstone Bridge output for flammable gases. Range 0-100%LEL for CH4, C3H8, C4H10 or Hydrogen. Two OLC10 TWIN sensors can be linked to a single channel on gas controller. Operating Range: -10 to +45°C, 0 to 95%RH. Dimensions: 118 x 126 x 58mm, IP65 ABS..
6513653
OLCT80D Wireless Transmitter with LCD display for flameproof remote sensor with 15m cable, sensor block available separately. The OLCT80 transmitter is supplied with 6 XP sealing plugs (4x M20 and 2 x M25), suitable cable gland kits are available separately to allow access to 2 auxiliary inputs (4-20mA or digital..
8032203322
N322 Electronic Thermostat for Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C..
9106A HART Transparent Repeater
9106A is a 1- or 2-channel isolated 1:1 repeater. The device supplies 2-wire SMART transmitters and can also be used for 2-wire SMART current sources. HART & BRAIN protocols are supported and are transferred bi-directionally...
9106A2B
Dual channel isolated HART transparent repeater, 2 x 4-20mA input, 2 x 4ƒ-20 mA output, power supply 19.2 - 31.2, Uo=25.6 V, SIL2 certified to IEC 61508..
9106B2B
Dual channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4…20 mA output, power supply 19.2 - 31.2, Uo= 25.6V, SIL2 certified to IEC 61508..
9107AB-U9
PR 9107AB-U9 Dual Channel HART Transparent Driver. Signal Splitter (1 In, 2 Out), or Dual Channels, Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus UL913 ATEX, IECEx,..
9107BB-U9
PR 9107BB Intrinsically Safe Single Channel HART Transparent Driver. Signal Splitter (1 In, 2 Out), or Dual Channels, Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area, or in Zone 2/Class I, Division 2 and transmit signals to Zone 1 0, 1, 2 and..
9203B2A1
Solenoid and alarm driver, ATEX approved 1 channel driver output, PNP input, SIL 2, high current version (50-60 mA), 19.2 - 31.2 VDC supply. Relay output...
AC1214
Mains Adaptor for CP11/CL11. Mains 100...240VAC Plug to 5vDC, mini USB out. Includes UK, EU and US Plug Options...
AP-700-O-PACKAGE-BT
The AP-700 Aquaprobe Package, AP-700-O-PACKAGE-BT, contains: Bluelink Adaptor; Aquaprobe AP-700 Probe, supplied with Optical Dissolved Oxygen, Conductivity, pH, ORP, TDS, SSG, Resistivity, Salinity and Temperature sensors; a 3m tough Cable with Connectors at both ends; Calibration Solutions; and various accessories all supplied in a Rugged Carry Case...
AP-800-O-PACKAGE-BT
The AP-800 Aquaprobe Package, AP-800-O-PACKAGE-BT, contains: Bluelink Adaptor; Aquaprobe AP-800 Probe, supplied with Optical Dissolved Oxygen, Conductivity, pH, ORP, TDS, SSG, Resistivity, Salinity, Optical Turbidity and Temperature sensors; a 3m tough Cable with Connectors at both ends; Calibration Solutions; and various accessories all supplied in a Rugged Carry Case...
B-565
20 channel input terminal, Withstand High Voltage type. Suitable for the GL860 data logger...
CCDDT-1000T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 1,000 Tonnes. Dimensions: Diameter 276mm, Height 80mm, Internal Radius 410mm..
DBEP Load Pin – Compression Load Cell
The DBEP shear pin load cells are designed for the measurement of both tension and compression forces in general applications such as process monitoring, offshore, civil engineering and industrial applications. They are environmentally sealed to IP67 as standard but can be enhanced to IP68 for fully submersible applications in sea..
DC to DC Converters for Sensor Excitation
We have a range of DC to DC converter modules, designed to power sensors requiring a 5vDC, 12vDC or 24vDC stabilised supply, where only a nominal 12vDC or 24vDC supply is available..
FS5704CV-6
Liquid flow switch with PVC wires, 1/4 inch NPT female connection, stainless steel body with viton seals. SPDT switch 0.3 amps at 120 VAC, operating temperature -40 to 105 deg C. Adjustable flow range set point at 0.5lpm to 4lpm..
FS6204CV-3
Miniature Gas Adjustable flow switch with 1/4 inch NPT connection. 316 Stainless Steel, adjustable flow range 1 slpm to 20 slpm..
FS6704CV-3
Miniature Liquid Adjustable flow switch with 1/4 inch NPT connection. 316 Stainless Steel, adjustable flow range 10 ml/min to 800ml/min..
HC2A-IC702-A
HygroClip 2. HC2A-IC702-A Industrial Cable Mounted Probe. Range 0-100%RH and -100 to +200°C, Accuracy ±0.8% RH, ±0.1°C. 15mm diameter (25mm Handle) PPS Probe with Stainless Steel 1.4301 tip with Hygromer HT-1 Sensor, 684mm (728mm with filter carrier) probe length and 2m cable to a 7 pin UART interface...
HITEMP140-TSK-2-TD
Submersible Datalogger with a PTFE thermal barrier for extreme temperature logging. Temperature Range: -200 to +250°C from a 100 ohms Platinum RTD with a resolution of 0.01°C. Internal Memory 65,536 readings, sample rate 1 second up to 24 hours and 2 year battery life. Operating Environment -40 to +140°C, (short-term..
Intrinsically Safe Temperature & Humidity Transmitter – HF5-EX
The HF5-EX series can only be used together with the intrinsically safe HC2-EX probes to provide a temperature and humidity monitoring system suitable for use in a Zone 1 or 2 Hazardous Area. The relative humidity and temperature can be displayed and output as analogue 4-20mA signals. Calculated psychrometric values..