0359900-020
CGR 4 Pyrgeometer with integrated PT100 temperature sensor. Silicon meniscus dome with hard carbon coating and infrared window materials to absorb short-wave radiation. Integrated leveling. Sun shield. Spectral range 4500-42,000nm, response time less than 18 sec (95%), temperature dependence of sensitivity less than 1% (-20 to +50°C). Operating temperature -40..
0362920-020
CMP 21 Secondary Standard Pyranometer. Two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 285-2800nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². PT100 output. Supplied with no plug or cable...
0362930-020
CMP 22 Secondary Standard Pyranometer. Two, 4mm thick, very high quality quartz domes. Integrated leveling. Sun shield. Spectral range 200-3600nm, response time less than 5 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. Sensitivity 7 to 14µV/Wm². PT100 temperature output. Supplied with no plug or cable...
0374900-200
SMP 3 Smart Pyranometer with 4-20mA output. Single 4mm glass dome. Integrated leveling. Sun shield. Spectral range 300 - 2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Digital output range -200 to 2,000W/m². Analogue output range..
0374905-200
SMP 10 Smart Pyranometer with 4-20mA output. Double 2mm glass dome. Integrated leveling. Sun shield. Spectral range 285 - 2800nm, response time less than 2 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Analogue output range 0 to 1600Wm², Digital output range..
0374920-200
SMP 6 Smart Pyranometer with 4-20mA output. Two, 2mm thick, high quality concentric domes. Integrated levelling. Sun shield. Spectral range 285-2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Analogue output range 0 to 1,600Wm², Digital output..
0374940-200
SMP22 Smart Pyranometer with a configurable 4-20mA output. Secondary standard pyranometer with a 32-junction thermopile sensing element under two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 250 - 3500nm, response time less than 2 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire..
0376900-200
SGR4-A Smart Pyrgeometer. Silicon meniscus dome with hard carbon coating and infrared window materials to absorb short-wave radiation. Integrated leveling. Sun shield. Spectral range 4400-50,000nm, response time less than 18 sec (95%), temperature dependence of sensitivity less than 1% (-20 to +50°C). Operating temperature -40 to +80°C. 2-wire RS485 Modbus..
1-Wire Analogue Input Transmitters
1-Wire Analogue Input Transmitters covering 0-20mA and 0-60V signals inputs with RJ11 connectors for easier daisy-chaining. The TSA200 is a 1-Wire current loop transmitter for 0-20mA/4-20mA inputs, converting analogue current signals from industrial sensors into digital data. In contrast, the TSV200-60i is a 1-Wire DC voltage sensor, designed to measure..
10130007
ComNav G1 GNSS Satellite Compass with G3 Colour Display. Output: NMEA2000. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 45° per second. Power Supply 10 to 36vDC (240mA @ 12vDC). The G1 contains a ComNav receiver..
111-761
P11 Protected Bulb pH Electrode for a pH range of 0-14. Combination electrode with a Silver/Silver Chloride, single porous Teflon junction. Eo point 0 to +/-25mV. Shaft dimensions (approx) 12mm diameter and 120mm length. BNC connector with 1m cable. Operating temperature 0 to 100 C. Suitable for pH monitoring where..
1957-0500-60-001
MaxiMet GMX500 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute Humidity, Air Density..
1957-0501-60-001
MaxiMet GMX501 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute Humidity,..
1957-0531-60-001
MaxiMet GMX531 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute..
1957-0550-60-001
MaxiMet GMX550 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index,..
1957-0551-60-001
MaxiMet GMX551 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill,..
1957-0560-60-001
MaxiMet Marine GMX560 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed and Direction, Air Temperature, Relative Humidity, Barometric Pressure and 6-Axis Compass. Compass allows compensations for tilt and provides pitch & roll data. Outputs: RS232, 422, 485 (ASCII), SDI-12, NMEA, MODBUS. Power Supply: 10-30vDC (Consumption 425mA @ 12vDC)...
1957-0600-60-001
MaxiMet GMX600 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Precipitation and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute Humidity, Air..
20/20MI-31SF
20/20MI Sharpeye Mini Short Range IR3 Flame Detector with cable output. Sensitive Range: 2.5 to 10m. Field of View: 100° Horizontal & 100° Vertical. Response Time: 5 seconds, adjustable up to 30 seconds. Automatic and Manual Built-In-Test. Output: Relays (SPST 30vDC @ 2A), 4-20mA (Fault = 0mA; BIT Fault =..
3109
3109 Slim Series Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of a single 0/2-10V, 0/1-5V and 0/4-20mA input signal to individually configurable 0/2-10V, 0/1-5V and 0/4-20mA on two output channels. The 3109 can also provide power supply and signal isolation to a 2 wire..
3186B1
3186B1 Single Channel 2-Wire Current Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of active current input signals within the range 3.8-20.5 mA, Response time: less than 5 ms, Accuracy 0.05% of span. Loop powered via the output loop, voltage drop <3V with a 10uA..
321.01.55.15.05.1.4
PTM/N submersible depth sensor, range 0 to 1 BarG (0-10mWG). Closed version with standard Viton seals and 12m PUR cable connection. Output - 2-wire, 4-20mA. Accuracy ±0.25%. Compensated temperature range -5 to 50°C..
3225B
3225B Slim Series Universal Converter suitable for use in Hazardous Areas. Frequency Input: 0.001Hz to 100kHz. Output: 1 Relay Output (Setpoint, Window, Sensor error, Latch, Power and Off). Power Supply: 24vDC ±30%, via power rail or terminals. 6mm Slimline housing...
400.0301
MC 4.0 ManoAir Manometer Display. Range ±20kPa. The MC 4.0 can measure absolute or differential pressures, filter and pitot tubes for ventiliation ducts. Measurement Range ±20kPa. Resolution: 0.01kPa, Accuracy: <100 Pa ± 0.03kPa + ±0.10%FS >100 Pa ±0.01kPa + ±0.10%FS. 3.2" TFT-Display, 2Hz measurement rate, internal logger for up to..