860-885
Legionnaires Standard Kit. Each kit contains: Therma 1 thermometer (221-041), Waterproof Surface Immersion Probe (323-046), Heavy-Duty PFA wire probe (133-372), Zip Pouch (830-037). Kits are supplied with a free traceable calibration certificate included...
88-PRO
LCD display, 3 1/2 digit, 12.7mm digits, loop powered, 4-20mA, voltage drop 2.5 volts, scaling by zero and span poteniometers. Dimensions 48 x 96mm...
8801801005
WL420 Submersible Hydrostatic Level Transmitter. Depth Range 1mH2O. 2-Wire Loop Powered 4-20mA Output with a 12-36vDC Power Supply. 5m Polyurethane (PUR) Cable with Ventilation Tube. Over-Pressure 300% FS, Burst Pressure 600% FS. Stainless Steel Sensor with 105mm Body Length and 26.5mm Diameter...
8802100120
TL400-V Non-Intrusive Laser Level Sensor. Suitable for tank level monitoring of liquids, grains or solids. Measuring Range: Up to 4m. Output Signal: 0.5-4.5V, Accuracy: up to 2mm. 3-pin Superseal Connector with 150mm cable. Interface: Mobile Device + SigNow Mobile App (Android and iOS). Power Supply: 8 to 33vDC. Consumption: 70mA..
8803006430
RHT-WM-485-LCD Wall Mounted Temperature and Relative Humidity Transmitter with LCD display and RS485 Modbus Output. Readings for Air temperature, Relative humidity and calculated Dew point values. Display can show two values, or temperature on its own. Temperature Range: -40 to +100°C, Relative Humidity Range: 0 to 100%RH and Dew Point..
8803016706
RHT-WM Wall Mount Temperature & Humidity Transmitter with a programmable 4-20mA output. Full programmable range: -40 to +120°C, Operational Range: -10 to +65°C. 12-30vDC loop power supply...
8804400110
RHT-AIR Wireless Temperature and Relative Humidity Transmitter. Temperature Range -40 to +100°C, Relative Humidity Range 0 to 100%RH. Power Supply Internal battery or 12 to 32vDC. Micro USB port for configuration via DigiConfig software. Operating Range, -10 to +70°C and 0 to 95%RH...
8811612420
DigiRail Connect DMIX Ethernet I/O Module. 8 Digital Inputs: High Logic Level (1): >2.2V, Low Logic Level (0): <1.5V; Pulse Counter; Digital State (NPN, PNP or dry contact). 8 Transistor Sourcing Digital Outputs, Actuation Modes:: Logical State; Pulse Duration; or Pulse Train. Power Supply 10-36vDC. Modules are DIN Rail mountable..
8812120000
FieldLogger data logger with 512k internal memory. 8 Universal Inputs, 2 Relay Outputs, 8 Digital I/O's and Mini USB Interface for PC Interface for programming, monitoring and downloading. Power Supply: 100-240vAC, with 24vDC auxiliary supply for connected devices. Complete model, with Ethernet, USB host for data downloading to USB memory..
8816001039
USB-i485 USB Converter to dual RS485 Isolated ports..
8818040031
FTR DIN Rail Transmitter Power Supply. Input 100-240vAC, Output 24vDC at 3W, 600V Isolation. IP40 grey polymide enclosure suitable for connection to a 35mm DIN Rail...
8830007000
PT100 temperature sensor with a 6mm diameter 316 Stainless Steel probe with 50mm probe length and ½" BSP thread connection. Suitable for temperatures from -50 up to 300°C. Transmitter housing suitable for any standard head mounted transmitter. Cable gland access for remote connection..
9106A1A
Single channel isolated HART transparent repeater, 4-20mA input, 4-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508..
9106B1A
Single channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4-20 mA output, power supply 19.2 - 31.2, SIL2 certified to IEC 61508..
9107AA
PR 9107AA Single Channel HART Transparent Driver. Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus ATEX, IECEx, FM, INMETRO, CCC and EAC-Ex Approvals. Power Supply: 19.2-31.2vDC, via..
9107BA
PR 9107BA Intrinsically Safe Single Channel HART Transparent Driver. Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area, or in Zone 2/Class I, Division 2 and transmit signals to Zone 1 0, 1, 2 and Zone 20, 21, 22, including mining/Class I/II/III, Div 1,..
9113BA
Temperature & mA Converter for hazardous areas. Single channel unit with active or passive mA outputs. Suitable for RTD, TC and mA inputs and SIL-2 certified....
9116B1
9116B1 Universal Converter IS Interface 4-20mA and Relay outputs. Max loop voltage <28vDC. Input Pt100, Pt1000, Ni100, TC types, RTD types, Potentiometer, Linear resistance, NAMUR, 0...12 VDC. Output 0-20 mA, 4-20 mA, 20-0 mA, 20-4 mA, Relay(s), 2-wire 4-20 mA..
9202A1A
Pulse isolator, 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply. With cable fault check (LFD) function...
9202B1A
Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and opto output, SIL 2, isolated, 19.2 - 31.2 VDC supply...
9203A1A
Solenoid and alarm driver, 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
9203B1A
Solenoid and alarm driver, ATEX approved 1 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
93.0406
Meteo anemometer and wind vane for windspeed & direction. Velocity measurements obtained via a cup star anemometer probe providing readings from 2.5 to 210km/h, output 0 - 2.1V (1V = 100km/h). Direction measurements obtained via a windflag providing readings from 0 - 360°, output 0 - 1vDC. Operating range -30°C..
93.0554
Meteorological Sensor with cup anemometer and wind vane for windspeed and direction monitoring. Wind Speed 0.7-40m/s, accuracy 0.3m/s (2% of reading). Wind Direction 0-360°, linearity ±0.5°, deadband 3°, ±1°. 2 x 4-20mA outputs for Wind Speed and Direction. Power Supply 9-26vDC. Material operating temperature -30 to +65°C. Type f.566.24.28..