Description
Features
- Insulated and encapsulated piezoresistive pressure sensor
- Front-flush, seamless design with no internal seals
- RS485 Interface can be combined with analog output
- Analog output is rangeable by RS485 Interface and CCS30 Software
- Modbus RTU Protocol available on RS485 Interface
- Excellent Long-term Stability, zero point adjustment via CCS30 software.
Electrical Information
Connectivity | Digital | 2-wire + Digital | 3-wire + Digital | 3-wire + Digital | 3-wire + Digital |
---|---|---|---|---|---|
Analog Interface | 4…20mA | 0…10V | 0…5V | 0.1…2.5V | |
Digital Interface | RS485 | ||||
Power Supply | 3,2…32vDC | 8…32vDC | 18…32vDC | 8…32vDC | 3.2…32vDC |
Power Consumption (without comms) | < 8mA | 3.5…22.5mA | < 8mA | < 8mA | < 8mA |
RS485 Voltage Insulation | ±32vDC | ||||
Note | Disturbance of the 4…20 mA signal occurs during communication via the digital interface | ||||
3-wire types are suitable for simultaneous operation of the analog and digital interface |
Available Electrical Connections
![]() |
![]() |
|||||
M12 | 2-Wire | 3-Wire | Binder 723 | 2-Wire | 3-Wire | |
M12 x 1 | 4-20mA | 0-10V | M16 x 0.75 | 4-20mA | 0-10V | |
![]() |
1: Out/GND | 1: GND | ![]() |
1: Out/GND | 1: GND | |
2: n.c. | 2: Output | 2: n.c. | 2: Output | |||
3: 8-32vDC | 3: 13-32vDC | 3: 8-32vDC | 3: 13-32vDC | |||
4: RS485A | 4: RS485A | 4: RS485A | 4: RS485A | |||
5: RS485B | 5: RS485B | 5: RS485B | 5: RS485B |
![]() |
![]() |
|||||
Cable Gland | 2-Wire | 3-Wire | DIN Connector | 2-Wire | 3-Wire | |
5.8mm Diameter Cable | 4-20mA | 0-10V | DIN 43650 | 4-20mA | 0-10V | |
![]() |
White: Out/GND | White: GND | ![]() |
|||
Red: n.c. | Red: Output | 1: Out/GND | 1: GND | |||
Black: 8-32vDC | Black: 13-32vDC | 2: n.c. | 2: Output | |||
Blue: RS485A | Blue: RS485A | 3: 8-32vDC | 3: 13-32vDC | |||
Yellow: RS485B | Yellow: RS485B | Case | Case |
Available Pressure Connections
1/2″ BSP Flush Diaphragm |
3/4″ BPS Flush Diaphragm |
![]() |
![]() |