AquaTel Telemetry Interface
Aquatel is a Smart telemetry device designed to simplify setup, lengthen deployment and optimise data management. Constructed with carbon fibre and aluminium, it features a long battery life and 4G modem communications. It houses a GPS receiver for location. Dissolved Oxygen or Water Level Measurement sensors can be used with..
Leveline-BARO Barometric Pressure Logger
The LeveLine-BARO Logger records atmospheric pressure in Bar, mBar, psi, kPa, mmHg, inHg, cmH2O and inH2O. It is the preferred method to compensate the absolute data recorded by the Absolute LeveLine sensors. One unit can cover all Leveline sensors within a 10Km radius...
Bluelink Aquaprobe Interface
The Bluelink Aquaprobe Interface is a Bluetooth-enabled device, with a rechargeable battery, designed to replace the Aquameter in portable monitoring setups. Connecting directly to the Aquaprobe cable, it interfaces with a dedicated Bluelink app that provides functionalities for real-time data viewing, sensor calibration, socket assignment for probes with additional sensors,..
AquaPlus Package
The AquaPlus probe is a combined optical dissolved oxygen, electrical conductivity and temperature sensor. Thanks to the built in conductivity sensor, the AquaPlus is able to calculate and automatically compensate DO readings for changes in water salinity. It's compact, robust and highly accurate. It also requires very little maintenance to..
Leveline Logger
The LeveLine is a precise water level and temperature logger designed for diverse seawater and surface water applications. Encased in a sealed unit, it integrates water level and temperature sensing capabilities. The LeveLine include a piezoresistive ceramic pressure sensor. Offered with multiple configurations and absolute or gauge options. This sensor..
Leveline-CTD Logger
The LeveLine-CTD is a precise water level, conductivity, salinity and temperature logger designed for diverse seawater and surface water applications. Encased in a sealed unit, it integrates conductivity, salinity, temperature and water level sensing capabilities. The LeveLine-CTD include a piezoresistive ceramic pressure sensor, plus a 4 ring stainless steel conductivity..
Leveline-Mini Water Level Sensor
The LeveLine-Mini is a precise water level and temperature sensor designed for diverse groundwater and surface water applications. Encased in a sealed unit, it integrates both temperature and level sensing capabilities. The LeveLine-Mini Absolute employs a durable piezoresistive ceramic pressure sensor, ensuring long-term stability and delivering an accuracy of 0.05%FS..
Leveline-Mini-CTD Water Level Sensor
The LeveLine-Mini-CTD is a precise water level, conductivity, salinity and temperature sensor designed for diverse seawater and surface water applications. Encased in a sealed unit, it integrates conductivity, salinity, temperature and water level sensing capabilities. The LeveLine-Mini-CTD includes the same piezoresistive ceramic pressure sensor as the Leveline-Mini sensor, plus a..
LeveLine QuickDeploy Key
The Leveline QuickDeploy Key will simplify your fieldwork with Leveline devices and saves you needing to take a laptop to site. It allows users to initiate data logging, perform zero point pressure references in data, ensuring accurate pressure readings against surface air pressure. It can also ensure battery and memory..
2000-AMM
AP-2000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-2000 Aquaprobe sensor..
2000-CAL
AP-2000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 2000-CAL is designed for use with the AP-2000 Aquaprobe sensor with pH probe...
2000-CHL
AP-2000 Chloride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). The 2000-CHL is designed for use with the AP-2000 Aquaprobe sensor..
2000-CPHYLL
AP-2000 Chlorophyll Electrode with 2 Auto-Range scales 0-99.99 µg/L or 100-500 µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L...
2000-FLU
AP-2000 Fluoride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 2000-FLU is designed for use with the AP-2000 Aquaprobe sensor with pH probe. Readings may be affected by Hydroxide ions...
2000-NIT
AP-2000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 2000-NIT is designed for use with the AP-2000 Aquaprobe sensor with pH probe...
2000-TURB
AP-2000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale. Minimum Level of Detection 0.0 NTU, Minimum Level of Repeatibility 5.0 NTU...
5000-AMM
AP-5000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-5000 Aquaprobe sensor..
5000-CAL
AP-5000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 5000-CAL is designed for use with the AP-5000 Aquaprobe sensor with pH probe...
5000-CHL
AP-5000 Chloride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-19,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). The 5000-CHL is designed for use with the AP-5000 Aquaprobe sensor..
5000-FLU
AP-5000 Fluoride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 5000-FLU is designed for use with the AP-5000 Aquaprobe sensor with pH probe. Readings may be affected by Hydroxide ions...
5000-NIT
AP-5000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 5000-NIT is designed for use with the AP-5000 Aquaprobe sensor with pH probe...
5000-TURB
AP-5000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale. Minimum Level of Detection 0.0 NTU, Minimum Level of Repeatibility 5.0 NTU...
7000-AMM
AP-7000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-7000, or AP-6000, Aquaprobe sensor..
7000-CAL
AP-7000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 7000-CAL is designed for use with the AP-6000, or AP-7000, Aquaprobe sensor with pH probe...