HC2-HK40
Hygroclip 2 High Temperature Probe. Default ranges: Temperature -100 to +150°C and Humidity 0-100%RH, Accuracy ±0.8% RH, ±0.1°C. 400mm handheld cable mounted PPS probe with 2m cable. The high performance PPS probe can withstand the wide operating range, yet has a low thermal mass - therefore providing faster response times..
MIEX64382
MiniAir 64EX Mini vane anemometer. Sensing head 22mm diameter x 28mm, probe length 175mm. Air velocity range 0-20m/s with a 4-20mA output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range up to +140°C. Steel sensing..
TMET
GEN II radio transmitter with wired connections for Vaisala Weather (WXT520) or Wind speed (WMT52) sensors, one thermistor and one mV input suitable for a CMP pyranometer. Thermistor Range -50 to +150 C, Resolution 0.05 C and Accuracy 0.1 C (-5 to +75 C). mV Range 0-50mV, Resolution 0.025% and..
MIEX64384
MiniAir 64EX Mini vane anemometer. Sensing head 22mm diameter x 28mm, probe length 175mm. Air velocity range 0-40m/s with a 4-20mA output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range up to +140°C. Steel sensing..
TT-PO511
Brass thermowell with 1/2 inch BSPT male thread suitable for temperature probes up to 6mm in diameter. Overall length 148mm with an immersion length of 110 mm and external diameter of 8mm (internal diameter 6mm). Brass thermowells are designed or use with non-agressive media only...
WBT
The WBT is an enclosure suitable for housing the TMET transmitter for outdoor installations. The unit can be wall mounted, or pole mounted on a 25mm lightweight Aluminium pole. Supplied with a key lock door and galvanised clamp for use on a 25mm diameter pole. Dimensions 200 x 300 x..
U9VL
9V Lithium Manganese Dioxide Battery. Capacity 1200mAh. Suitable for use with the XR440 Pocket Logger...
ULTRASHOCK-100
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±100g Triaxial Acceleration; -20 to +60°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-100-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±100g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-250
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±250g Triaxial Acceleration; -20 to +60°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-250-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±250g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-5-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±5g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-50
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±50g Triaxial Acceleration; -20 to +60°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
ULTRASHOCK-50-EB
UltraShock Dynamic Environment Data Logger with an integrated triaxial accelerometer, temperature, humidity and pressure sensors. Ranges: ±50g Triaxial Acceleration; -20 to +54°C Temperature; 0 to 95% Relative Humidity; and 0 to 30PSIA Pressure. Internal memory 174,762 readings per channel. Configurable logging rates: Acceleration 64Hz to every 5 mins; Temperature, Pressure..
USB-010100
USB Meter Reader for wireless meter reading of Multical 402 Ultrasonic Heat Meter. Starter pack including USB Reader, internal antenna and Power Pack. The Kamstrup USB Meter Reader is used for quick and simple reading of Kamstrup electricity, heat, cooling and water meters fitted with a radio module with EU..
USB-AD
USB-AD USB Data Acquisition Cable. The 1.1m cable consists of a USB 2.0 port connecting to a 37-pin D-Sub Female Connector. The 37-pin connector allows up to 16 Analogue Inputs (±5V), 1 Analogue Output (±5V) and 8 Digital Input/Outputs, Plus One 32-Bit Counter Input to be connected. 12-Bit Resolution and..
USB-AD14F
BMCM USB Data Acquisition Unit. 16 Analogue Inputs (Range: ±10V) with a 14-bit Resolution and 20kHz Sampling Rate across all used channels, plus 8 Digital Inputs, 8 Digital Outputs, including one 16-bit Counter Input, and 1 Analogue ±5V Outputs. Power Supply: 4.5-5.5V from USB connection to the PC, max 100mA...
USB-AD16F
BMCM USB Data Acquisition Unit. 16 Analogue Inputs (Range: ±10V, ±5V, ±2V or ±1V) with a 16-bit Resolution and 250kHz Sampling Rate across all used channels, plus 4 Digital Inputs, 4 Digital Outputs, including one 16-bit Counter Input, and 2 Analogue Outputs (±10V with 16-bit Resolution). Power Supply: 4.5-5.5V from..
USB-DAQ
MS-IMU3020 Specific USB Data Acquisition Module..
USB-M-8.5UR
USB Data Acquisition Module. USB Powered, 8.5V..
USB-PIO
USB-PIO USB Digital I/O Interface Cable. The 1.1m cable consists of a USB 2.0 port connecting to a 25-pin D-Sub Female Connector. The 25-pin connector allows up to 24 Bi-Directional Digital Input/Outputs Channels. USB Bus Powered. Operating Temperature 0 to +70°C. Can be used together with multiple OR8, splitter cable..
USBMODE003
USB lead and PC software for programming...
VIEW-USB-485
SenixView Setup Software Kits. Windows compatible, use with all ToughSonic sensors. UA-KITs include CD, power supply, 9-pin DB9 COM port RS485 cable and USB to RS485 adaptor...
VOLTAGE ATTENUATOR 10:1
The 10x attenuator divides the input voltages by a factor of 10:1 Maximum input voltage is 500vDC. Input impedance is 1MOhm. Fast mounting on all channels and has safety banana connectors on both ends and Gilded contacts...