The PR5335D is an intrinsically safe, head-mounted 2-wire transmitter combining temperature and process signal conversion with HART 5 communication. It accepts supported RTDs, thermocouples, linear resistance and bipolar millivolt inputs, producing a 4–20 mA output for compatible monitoring and control equipment. Designed for DIN form B sensor heads, it provides configurable measurement close to the sensor in suitably designed hazardous-area installations.
The 5335D supports linearised temperature measurement with platinum and nickel RTDs, including PT100 and PT1000, alongside supported thermocouple types. RTD and resistance inputs accommodate two-, three- and four-wire connections, with cable compensation appropriate to the selected arrangement.
Linear resistance and bipolar millivolt conversion extend its use to compatible resistive sensors and low-level voltage sources. The input type and measurement range are configured to match the application.
Compatible two-sensor arrangements allow the transmitter to calculate a temperature difference or average. Differential measurement can compare two process locations, while averaging combines readings into a single reported value.
The selected sensors and wiring must suit the configured measurement function. These options allow the transmitter to handle tasks beyond individual temperature measurement without requiring a separate calculation device.
HART communication provides digital access over the same two-wire loop used for transmitter power and the current output. In conventional point-to-point operation, the 4–20 mA signal represents the configured measurement while compatible HART equipment accesses digital information and settings.
This supports commissioning and maintenance through the measurement loop. Where a barrier or isolator is installed, it must support HART communication if digital access is required across that interface.
The 5335D can be configured using compatible HART equipment or PR Electronics PReset software with a suitable Loop Link interface. Settings are matched to the sensor type, measurement range and required output behaviour.
Programmable sensor error indication provides a defined output response when a sensor fault is detected. Receiving equipment can use this response to distinguish a measurement problem from a normal process value.
Galvanic isolation separates the sensor input from the output circuit. The loop-powered arrangement uses two wires to supply the transmitter and carry its measurement signal.
The 5335D carries hazardous-area approvals, including ATEX and IECEx, for installation within the relevant certification conditions. The sensor, enclosure, associated barrier or isolator and loop wiring must form a compatible intrinsically safe arrangement.
Before selection, confirm the input configuration, loop requirements, ambient conditions and approval needed at the installation location. For applications requiring selectable HART 5 or HART 7 communication, consider the 5337D.
| Type | Version |
| 5335 | A: General Purpose, Zone 2, Div 2 D: Zone 0, 1, 2, 21, 22, M1/Div 1, Div 2 |
Applications
Frequently Asked Questions
PR 5335D 2-Wire Programmable Transmitters with HART 5 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 Protocol. Accuracy ≤±0.05% of span. Response Time: 1 to 60 Seconds. Power Supply 8-30vDC @ 0.7W Max. 1.5kVAC Galvanic Isolation. Namur NE21, NE43 and NE89. Approvals: ATEX, IECEx, FM, CSA & INMETRO; DNV Certification; SIL Hardware Assessment. Operating Temp: -40 to +85°C.
USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.
A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.