Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket
Home / Display & Control Products Signal Amplifiers / 5335D
5335D

5335D

PR 5335D 2-Wire Programmable Transmitters with HART 5 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 Protocol. Accuracy ≤±0.05% of span. Response Time: 1 to 60 Seconds. Power Supply 8-30vDC @ 0.7W Max. 1.5kVAC Galvanic Isolation. Namur NE21, NE43 and NE89. Approvals: ATEX, IECEx, FM, CSA & INMETRO; DNV Certification; SIL Hardware Assessment. Operating Temp: -40 to +85°C.

£400.00

Need help finding the right product?

CONTACT US

Downloads

Datasheet

5535D Temperature Transmitter

  • Description

Description

The PR 5335D is an intrinsically safe, head-mounted 2-wire transmitter that converts RTD, thermocouple, resistance and millivolt inputs into a 4-20 mA output with HART 5 communication. Designed for DIN form B sensor heads, it supports individual, differential or average temperature measurement with compatible sensors. Galvanic isolation and hazardous-area approvals suit industrial installations requiring intrinsically safe measurement, subject to certification conditions.

Applications

  • Linearised temperature measurement with PT100/1000, Ni100/1000, or TC sensor.
  • Difference or average temperature measurement of 2 resistance or TC sensors.
  • Conversion of linear resistance variation to a standard analogue current signal, for instance from valves or Ohmic level sensors.
  • Amplification of a bipolar mV signal to a standard 4-20 mA current signal.
  • Connection of up to 15 transmitters to a digital 2-wire signal with HART® communication.

Features

  • RTD, TC, Ohm, or mV input
  • Galvanic isolation
  • For DIN form B sensor head mounting
  • Extremely high measurement accuracy
  • HART® communication

HART Protocol

The HART protocol provides a uniquely backward compatible solution for instrument communication as both 4-20 mA analogue and digital communication signals are transmitted simultaneously on the same wiring. The Loop Link Programming Kit can configure the individual transmitters for multi-drop mode and provide it with a unique polling address. HART provides many benefits promised by fieldbus, while retaining the compatibility and familiarity of existing 4-20 mA systems.

Options

Type Version
5335 A: General Purpose, Zone 2, Div 2
D: Zone 0, 1, 2, 21, 22, M1/Div 1, Div 2

If required, Omni Instruments will program a 5335 to your specific requirements. Please contact us for details.

Product

Ref

Price

Product Description

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000