3102
3102 Slim Series PT100 Temperature Converter suitable for use in ATEX Zone 2 Environments. Conversion of 2-, 3- or 4- wire PT100 temperature sensor input signal to a 0(2)-10V, 0(1)-5V or 0(4)-20mA output signals. Response time: less than 30ms (300ms when signal dampening), Accuracy better than ±0.1% of span. Power..
3104
3104 Slim Series Isolated Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of 0/2-10V, 0/1-5V and 0/4-20mA input signals to 0/2-10V, 0/1-5V and 0/4-20mA output signals. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply: 24vDC ±30%, via power rail or terminals. 6mm..
3186A2
3186A2 Dual Channel 2-Wire Transmitter Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of passive current input signals with 3.5-32.5V excitation, Response time: less than 5 ms, Accuracy 0.05% of the 3.8-2.05mA span. Loop powered via the output loop, voltage drop 2.5V typical. 6mm Slimline..
400.0351
Lab 4.0 - Manometer with 2 included modules: ±250Pa, ±2,500 Pa (other on request) Touch Screen and 10,000mAh Battery Stainless Steel version. Dimensions 270 x 245 x 95mm, Weight 2.4Kg..
420.0110
ThermoAir Pro Omnidirectional (V) Thermal-Electric Omnidirectional Anemometer. Air Velocity Range: 0.015-1m/s with a 0-1V Output. Accuracy ±1.0% of full scale. Sensing head surrounded by a removable 110mm diameter protective cage, handle 15mm diameter, probe length 270mm. The probe measures the flow velocity from all directions in the measuring plane perpendicular..
4222 Universal I/f Converter
The 4222 is a universal current/voltage to frequency converter. The 4222 accepts RTD, TC, Ohm, potentiometer, mA and V inputs and produces a frequency output between 0.001 and 25,000 Hz. The unit can be programmed via the detachable 4501 display front...
5104A–B
PR Electronics model 5104 programmable transmitter, 24 - 230 V AC/DC power supply, dual channel with 0-20, 4-20mA or voltage input and mA or voltage output. See data sheet for input and output options..
5105B-B
Ex-Isolated Driver, 2 Channels, ATEX II (1) GD, mA, V 24...230 VAC/DC..
5106AB-B
Hart Transparent Repeater, 2 Channels, 4...20 mA, 24...230 VAC/DC..
5114A-B
Dual channel 5114A programmable transmitter. Dual channel unit for RTD, TC, mV, linear resistance, mA and V inputs, producing a (0)4-20mA, 0-10vDC output. 3-port 3.75 kVAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail. Power Supply 21.6 to 253vAC or 19.2 to 300vDC...
5131-A-B
Dual channel 2-wire programmable transmitter with a 7.5-35vDC power supply. Please specify the required inputs for each channel RTD, TC, R, mA, mV or V. Output 4-20mA...
5202B2
5202B2 2 Channel Pulse Isolator with 2 Relay Outputs. Units will accept NAMUR or mechanical contact inputs. Power supply 21.6 - 253 vAC or 19.2 - 300vDC. Units are suitable for Hazardous Area Installations, ATEX II (1) GD...
5203B–2
Ex Solenoid / Alarm Driver, 2 ch., ATEX II (1) GD, NPN, PNP, Switch, 24...230 VAC/DC..
5223B1
ATEX programmable f/I-f/f converter with a 24-230vAC/DC power supply. Analogue output mA, mV, V and NPN/PNP output...
5331D3B
PR 5331D3B 2-Wire Programmable Transmitters. Inputs: -12 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 5000Ω. Output: 4-20mA. Accuracy ≤±0.05% of span. Response Time: 1 to..
5333D
PR 5333D 2-Wire Programmable Transmitters. Inputs: RTD (2 or 3 Wire) Range -200 to +850°C; Linear Resistance – 0 to 10,000Ω. Output: 4-20mA. Accuracy ≤±0.1% of span. Response Time: 0.33 to 60 Seconds. Power Supply 8-30vDC @ 0.7W Max. Namur NE43. Approvals: ATEX, IECEx & INMETRO; DNV & EAC EX..
5334B3B
PR 5334B3B 2-Wire Programmable Transmitters. Inputs: -12 to 150mV; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Output: 4-20mA. Accuracy ≤±0.05% of span. Response Time: 1 to 60 Seconds. Power Supply 8-30vDC @ 0.7W Max. 1.5kVAC Galvanic Isolation. Namur NE21, NE43. Approvals: ATEX,..
5335D
PR 5335D 2-Wire Programmable Transmitters with HART 5 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 Protocol...
5337D
PR 5337D 2-Wire Programmable Transmitters with HART 5/7 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 or..
5343B
PR 5343B 2-Wire Programmable Level Transmitters. Inputs: ); Linear Resistance – 0 to 100kΩ or Potentiometer 10 to 100kΩ. Output: 4-20mA. Accuracy ≤±0.1% of span. Response Time: 1 to 60 Seconds. Power Supply 8-35vDC @ 0.8W Max. Namur NE43. Approvals: ATEX, IECEx, FM & INMETRO; DNV & EAC EX Certification;..
5714B
PR 5714B 4 Digit Red LED display. Accepts a single 4-20mA, 0-1V, 0.2.1V, 0-10V, PT100 and Thermocouple inputs. Programmable via front keys, 2.3kVAC Galvanic isolation and 2 x Relay outputs. Universal power supply: 21.6 to 253vAC or 19.2 to 300vDC. IP65 Rated with dimensions of 48 x 96 x 120mm,..
5715D
PR 5715D 4 Digit Red LED display. Accepts a single 4-20mA, 0-1V, 0.2.1V, 0-10V, PT100 and Thermocouple inputs. Programmable via front keys, 2.3kVAC Galvanic isolation, 4 x Relay and Analogue 4-20mA output. Universal power supply: 21.6 to 253vAC or 19.2 to 300vDC, plus Auxiliary supply for sensors of 16-25vDC /..
5725D
Digital display, 4 digit red LED display, pulse or frequency input, P/S 21.6 - 253vAC/19.2-300vDC. 2 X relay O/P and 1 x 0/4-20mA output. Programmable via front keys...
61208
Data Downloading Software. Comes with CD-Rom, Communications and User Instructions. Suitable for PS500 Portable Gas Detector with integrated Data logger...