PS500 Multi Gas Detector
The Personal Surveyor (PS500 Series) is a robust and accurate portable gas detector that provides personal protection in confined space applications with audible and visual alarms in the event of exposure to dangerous levels of gases being detected. The PS500 unit can be fitted with any 4 of the 20..
QR-C-112
SafEye Quasar 900 Receiver Unit. Warm up time: 30 seconds. RS485 Modbus Interface and HART Comms. Analogue Output: 0-20mA (Sink). Output: Fault = 0-3mA; Normal Readings = 4-20mA. Power Supply 18-32vDC @ 250mA (Peak: 30mA). ATEX/IECEx Approved Ex d e ib [ib Gb] IIB+H2 T4 Gb, Ex tb IIIC T135°C..
RC250 Modbus GEN II Receiver
The RC250 Modbus GEN II Receiver can be used as a receiver unit for the GEN II transmitters to provide a serial Modbus output for up to 160 active channels. The RC250 is a self-contained mains powered receiver unit with built-in batteries providing more than 24 hours of operation in..
RI-TV Series Isolated True RMS Voltage Transducer
A DIN Rail mounted voltage transducers suitable for converting AC and DC voltage to a proportional mA or voltage output. The TVV0010 is powered by a 85-265vAC mains supply and TVV0040 is powered by 10-36vDC with a full range of selectable AC voltage inputs and mA or V outputs. The..
RI-TVV0040
RI-TV Series Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 0-20mA, 4-20mA, ±20mA, 20-0mA, 20-4mA, 0-5V, 0-10V, ±5V, 10V, 10-0V. Supply Voltage: 10-36vDC @ 1.5W. Operating Temp -20 to +60°C, IP20...
RMS1-OT-11088-0X-GR-MB
Remote I/O Module, 8 Opto isolated digital inputs, 8 Open Collector Digital Outputs. RS232/RS485 Modbus ASCII/RTU Communication, Wide power supply range: 10 up to 30vDC, DIN rail mounting...
RMS1-TD-01000-40-IA4-MB
Temperature Acquisition Module. 4 inputs for temperature digital probes, temperature range -55 C to 125 C. RS485 Modbus Slave communication. Wide power supply range of 10 up to 30vDC. Din Rail Mounting..
RMS2-PT-110-00-80-IA3-MB
RMS2-PT PT100 Acquisition Module. The unit provides 8 Differential Input Channel suitable for 2- or 3-wire PT100 temperature sensors. An RS232 and RS485 isolated pluggable terminal blocks (Modbus RTU/ASCII Slave) plus USB port for configuration. DIN Rail mounted industrial enclosure with terminal blocks. Power supply: 10-30vDC, consumption 50mA @ 12vDC...
RTD-SURFACE-FLAT-2MFL
Self-Adhesive Surface Mounted PT100 Class A Sensor with 2m PFA Insulated Cable. Measurement Range -30 to +150°C. Suitable for flat surface mounting with a 16 x 37mm rubber patch..
RTR500BW
RTR500BW Network Base Station/Repeater with RJ45 Wired, or Wireless, LAN Connection, and USB 2.0 connection for configuration. FTP and email alarm software supplied, but will require PC with Internet access and SMTP server to provide emails. Downloaded data can be sent to email or server at scheduled intervals, or under..
Rutland 505 Windcharger
The Rutland 505 Windcharger is ideal for trickle charging battery banks of up to 100Ah. It is ideal for use in off-grid remote monitoring systems to provide a constant charge to the batteries. The Rutland 505 model has been designed with a 20% higher power output than the Rutland 504..
SCA Series Inclinometers
The SCA Series inclinometer are industrial grade inclinometers with options for voltage or current analog and serial data outputs. The SCA inclinometers are available in a rugged industrial enclosure, or as an OEM board for installation into your own equipment or enclosure. Accuracy up to 0.02, fast angle response of..
Senturion XPR04 Proximity Probe
The Senturion XPR04 proximity probe system is an 8mm tip proximity sensor that uses eddy current principle to measure distance up to 2.5mm or 4mm with resolution of less than 1 micrometer. It is designed for monitoring targets from as little as 16mm in applications, even those in a harsh..
SGA/D
SGA/D Mains Power Strain Gauge Amplifier for Load Cells and Stain Gauges. Power Supply 18/24vDC. 5 or 10V Bridge Excitation with Bridge Sensitivity 0.06 to 30mV/V and Output Options: ±5, ±10, 0-5 or 0-10V and 0-20 or 4-20mA. Operating Temperature Range -10 to +50°C, IP67 ABS Housing with 3 M16..
SGR Series Rotary Transducer For Torque, Speed & Power Measurements
These SGR Series Transducers can be used to monitoring bi-directional rotary or static torque. A speed sensor for monitoring in dynamic applications, enabling direct measurements of transmitted power and RPM. The SGR Series Transducers operate using a four-element strain gauge wheatstone bridge, which connects to a microcontroller to process the..
SGR4 Smart Pyrgeometer
The SGR4 is a Smart Pyrgeometer, designed to provide meteorological measurements of downward atmospheric long wave radiation. The construction of SGR4 pyrgeometers is identical to the CGR4 pyrgeometers but it includes a Modbus interface and amplified analogue output. The SGR4 uses a thermopile detector in a spectral range of 4.5..
SGR512
SGR512 TorqSense Torque sensor with a fixed analogue outputs for Torque, Speed and Power measurements with integral electronics. Torque ranges from 0-175mNm to 0-13,000 Nm and 360 Pulse/Revolution...
SGR520/521/522 Series Digital Rotary Torque Transducer
The SGR520/521/522 TorqSense Transducers offer RS232, CANBus, USB and Ethernet outputs as well as variable voltage or current outputs for Torque, Speed/Angle and Power monitoring. Featuring BIT self-diagnostics, a status LED, an output pin for health feedback, and temperature sensors for enhanced accuracy...
SGR533
SGR533 TorqSense Torque sensor with a fixed analogue outputs for torque and power measurements with external electronics. Torque ranges from 0-1Nm to 0-13,000 Nm...
SGR540 TorqSense Transducer
SGR540 TorqSense Transducer for Torque Measurements with External Electronics and Digital (RS232, CANBus, USB or Ethernet) outputs. SGR540 can provide readings for Torque Only with a variable analogue current or voltage output with a power supply 12-32vDC. Select Options to build your own the SGR540 on our Part Builder...
SGR541 TorqSense Transducer
SGR541 TorqSense Transducer for Torque Measurements with External Electronics and Digital (RS232, CANBus, USB or Ethernet) outputs. SGR541 can provide readings for Torque, Speed and Power with 60 pulse per revolution encoder with variable analogue current or voltage outputs with a power supply 12-32vDC. Select Options to build your own..
SGR542 TorqSense Transducer
SGR542 TorqSense Transducer for Torque Measurements with External Electronics and Digital (RS232, CANBus, USB or Ethernet) outputs. SGR542 can provide readings for Torque, Speed/Angle and Power with 360 pulse per revolution encoder with up to 3 variable analogue current or voltage outputs with a power supply 12-32vDC. Select Options to..
SII4R2
COM port redirector driver enables legacy serial software to gain access to the network. 1 seat. 2 virtual Serial COM...
SP-LITE-15M
SP-LITE Pyranometer is suitable for solar irradiance measurements in spectral ranges of 400 to 1100nm up to a maximum of 2,000 W/m² with response time less than 1 seconds and typical sensitivity of 10µV/W/m² that varies less than 0.15%/°C from -30 to +70°C. The pyranometer uses a Double 2mm glass..