SPA-PE-FD2
White POM Filter Carrier and Polyethylene Filter with 2µm size pores. Suitable for HC2A-S Probes. Waterproof Filter with Temperature Range -50 to +100°C..
CAL-9054
Calibration of a Tinytag Energy Logger, Brand New or returned to us for recalibration. Calibration points cover a range of currents from 10 to 1000A per-phase in both the single and three phase modes of operation. Voltage, power and power factor readings are all tested. Returned loggers: Please complete the..
CAL-9002
Service Calibration of Tinytag loggers returned to us for recalibration. Calibration at temperatures of 0 and 30°C. This calibration covers single channel data loggers. Please complete the Calibration Return Form and send with your loggers. Returned loggers will be fitted with a new battery and any seals or desiccant packs..
CAL-9004
Service Calibration of Tinytag loggers returned to us for recalibration. Calibration at temperatures of 0 and 30°C and Relative Humidity at 20%RH and 70%RH (at 25°C). This calibration covers Dual channel data loggers. Please complete the Calibration Return Form and send with your loggers. Returned loggers will be fitted with..
CAL-9052
Service Calibration of a Tinytag CO2 Logger returned to us for re-calibration. Calibration at 500, 1,000 and 1,500ppm for 2,000ppm units and 500, 2,500 and 4,000ppm for 5,000ppm units. Returned loggers will be fitted with a new CR2325 coin cell battery..
CAL-9001
Additional/Alternative calibration points for both initial and service calibrations. Price is for each additional point of temperature or humidity. Temperatures in the range of -20 to +125°C and Humidity 20 to 90 %RH (at 25°C)..
SPA-SS
Sintered Steel Filter Carrier. Suitable for HC2A-IC, HC2A-IM and HC2A-IE Probes. Temperature Range -100-200°C...
SPA-SS-PTFE
Stainless Steel 1.4301 Filter Carrier and White PTFE Filter with 10µm size pores. Suitable for HC2A-IC, HC2A-IM and HC2A-IE Probes. Temperature Range -100 to +200°C..
SPA-SS-WM
Stainless Steel 1.4301 Filter Carrier and Wire Mesh Filter with 10µm size pores. Suitable for Industrial HygroClip Probes: HC2A-IC; HC2A-IM; and HC2A-IE. Temperature Range -100 to 200°C...
SPA-SSS
Sintered Steel Filter Carrier and Wire Mesh Filter with 10µm size pores. Suitable for HC2A-IC, HC2A-IM and HC2A-IE Probes. Temperature Range -100-200°C...
SPA-WM
Polyethylene Filters for Industrial Hygroclip probes. Wire Mesh Filter Sleeve (Pore size 10µm)..
ED-0001
Custom scaling of Tinytag Plus 2 and View 2 Instrumentation Data Loggers for third party sensors. Price per logger. Returned loggers only, please order parts ending -ED for new loggers...