17124975-5
Replacement MX6 Sensor for Sulphur Dioxide (SO2). Range 0 to 150ppm, Resolution 0.1ppm. Response time 5 seconds..
17155823
The replacement DualSense pack of Carbon Monoxide, low hydrogen interference sensors for the Tango TX1-G Gas Detector. The CO/H2 Low sensor has a measuring range of 0-1000 ppm with a 1 ppm resolution. The Cells use two electrodes and a special catalyst with a lower sensitivity to Hydrogen to detect..
17124975-6
Replacement MX6 Sensor for Ammonia (NH3). Range 0 to 500ppm, Resolution 1ppm. Response Time 21 Seconds (T50)..
17124975-7
Replacement MX6 Sensor for Chlorine (Cl2). Range 0 to 50ppm, Resolution 0.1ppm. Response Time 6 Seconds (T50)..
17124975-8
Replacement MX6 Sensor for Chlorine Dioxide (ClO2). Range 0 to 1ppm, Resolution 0.01ppm. Response Time 7 Seconds..
17124975-9
Replacement MX6 Sensor for Phosphine Low (PH3). Range 0 to 5ppm, Resolution 0.01ppm. Response Time 5 Seconds (T50)..
133-220
General Purpose K-Type Penetration Probe, 100mm x 3.3mm diameter. Supplied with 3 metre PTFE Insulated Lead and a K Therm MiniPlug connector. Probe Temperature Range: -75 to +250°C, Response Time: <5 Seconds. Part Ref 133-220..
17124975-A
Replacement MX6 Sensor for Hydrogen Chloride (HCl). Range 0 to 30ppm, Resolution 0.1ppm. Response time 17 seconds (t50)..
3462523
2 Metre Cable with IP67 M12 Mating Connector. Colour Coding: Pin 1 - Brown, Pin 2 - White, Pin 3 - Blue, Pin 4 - Black...
551-73
500ml Zero Solution for Dissolved Oxygen Electrode..
888257
Quasar 900 Series Extended Commissioning Kit, Covers Methane, Propane and Ethylene. The kit includes an alignment tool, a magnetic mode selector, 6 functional check filters (Part No. 888260-1, 88260-2, 888260-3, 888260-4, 888260-5 and 888260-6), socket keys and non-EX USB/RS485 harness converter kit.. Used for System installations and periodical function tests..
B-514
DC power cable for GL Series data loggers. Cable is 2m long with flying leads on one end and power adaptor on the other...
CAL-SCS-THERMOAIR
SCS Calibration Certificate for ThermoAir anemometers and Thermoelectric anemometers fitted to ThermoAir display units. Price covers a 5 point calibration..
CAL2AXISROTATE
Calibration 2 Axis - Rotate (Wind Tunnel). The calibration procedure involves a fixed wind velocity and the unit is rotated from 0 to 360 Degrees in 180 separate steps, providing a reading every 2 Degrees. The calibration certificate then compares the fixed wind velocity of the wind tunnel to the..
CALCERT B
Recalibration Certificate for Infrared Sensors, PyroMini, PyroCouple and PyroPen. UKAS traceable certificate showing the measured temperature at three points across the sensors temperature range...
CALPROB
2 Point calibration of oven temperature probe...
CDI-SC
RS-485 Serial Communications Module for the CDI Flow Meters..
CMC-99-EMAIL
CMC-99 E-mail Notifications Licence Key. CMC-99 will automatically send Email notification messages via Ethernet connection. E-mail notifications can be used as devices state report when an alarm or a specified signal occurs...
CP420
Loop powered rate and totaliser display with 4-20mA output for flow rate..
E2-02XX
2m Anthracite extension cable for HC2 Probe with flying leads..
GC-62
GEN II radio transmitter for use with pulse outputs from flow, gas, energy or heat meters and any other devices with a pulse output. The transmitter will accept up to 2 pulse inputs, max 250Hz and 65,000 pulses per logging period, counter resets for each transmission. Operating Range -30 to..
HITEMP-IFC406
HiTemp USB Download Multiplexer interface with 6 Ports. Supplied with software, manual, docking station and USB connection cable..
MTN/MS013
¼" - 28 UNF male to stainless steel flat base adapter for attachment with epoxy resin. Provides a rigid connection that maximises the response at high frequencies...
NPL-CAL-11 POINTS
Initial Calibration of pressure sensors purchased from Omni Instruments. Pressure Calibration to 11 points. All ranges between -0.8 and 1,000 Bar. Certificate shows actual output readings in graph and table form. Maximum errors shown at each point as a percentage. Certificate is timed, dated and has a unique reference for..