18107011
Single-Unit Automotive Charger with 12vDC cigarette lighter plug for MX6 multi-gas detector...
820KCG13DI
CG-3DI ClickNGo Module, 3 Digital Input Module. Size 1 Module with three PNP, NPN or Dry Contact inputs. Operating Temp -20 to +60°C, 80%RH. Dimensions: 53.8 x 10.6 x 22.2mm, Weight: 10g. IP50 when installed in controller...
DTI-EMF-ELECTRODE-TITANIUM
Titanium Electrodes for DTI-EMF Electromagnetic Flow Meter. Suitable for: Salts (Chloride, Magnesium Aluminium, Calcium, Iron, (etc); Sodium Salt, Potassium Salt, Hydrochlorite, Sea Water; Potassium Hydroxide, Hydroxide Amine, Barium Hydroxide Alkali Solution. (Concentration less than 50%); Acids (Hydrochloric, Sulphuric, Phosphoric, Hydrofluoric and other Reducing Acids...
GL7-L/P
16 channel logic pattern or pulse count module. Bi-level signal, up to 24V, select either Logic or Pulse mode, Logic: Signal pattern, Pulse: Counting in instant, accumulating, rotation (max. 15 million count). Sampling rate Logic: up to 1s interval, Pulse: up to 100s. 4 circular connectors (10 position, socket) with..
GS-3AT
GS-3AT Acceleration and temperature sensor. Acceleration, in 3-axes, range max 10g. Temperature -10 to 50°C. The sensor can provide Peak (largest value each interval), average (mean value during interval) and RMS (root mean square value) acceleration readings at set sampling rates of 500ms up to 60 mins (Sub-sampling interval is..
OceanDISP-1K
OceanDISP-1K subsea LED display unit suitable for displaying sensor readings from Datataker DT80 and DT85 data loggers. Light activated scrolling display with programmable scroll interval. Suitable for depths up to 1,000m..
0362613
Waterproof 4-pin plug connector with 25m of pre-wired high quality yellow signal cable with 4 wires and a shield covered with black sleeve. Suitable for the following Kipp & Zonen equipment. CMP Series pyranometers, CGR3 & CGR4 pyrgeometers and CVF4 & CNF4 ventilation units...
18107243
Single-Unit Truck-mount Charger with 12vDC cigarette lighter plug for MX6 multi-gas detector...
DTI-EMF-ELECTRODE-TANTALUM
Tantalum Electrodes for DTI-EMF Electromagnetic Flow Meter. Suitable for: Hydrochloric Acid (Concentration less than 40%); Dilute Sulphuric and Concentrated Sulphuric Acid (Excluding Fuming Sulphuric Acid); Chlorine Dioxide, Ferric Chloride, Hypochlorite, Sodium Cyanide, Lead Acetate, etc; Nitric Acid (including Fuming Nitric Acid) and other oxidizing Acids; Alkali, Hydrofluoric Acid..
0362614
Waterproof 4-pin plug connector with 50m of pre-wired high quality yellow signal cable with 4 wires and a shield covered with black sleeve. Suitable for the following Kipp & Zonen equipment. CMP Series pyranometers, CGR3 & CGR4 pyrgeometers and CVF4 & CNF4 ventilation units...
DTI-EMF-ELECTRODE-PLATINUM
Platinum Electrodes for DTI-EMF Electromagnetic Flow Meter. Suitable for: Almost All Acid, Alkali and Salt Solutions (Including Fuming Sulphuric and Fuming Nitric Acids; Aqua Regia, Ammonium Salt..
0362615
Waterproof 4-pin plug connector with 100m of pre-wired high quality yellow signal cable with 4 wires and a shield covered with black sleeve for CMP Series Pyranometers and Pygeometers with 10K thermistor output...
APS-SERIES-AP
APS Series Autopilot Platform :size (2.63 inch W x 2.10 inch H x 2.63 inch D) , 30 fully programmable digital I/O lines , 4 RS-232, full duplex UARTS , PWM inputs and outputs for servo control , 12 Analog inputs (12 bit) , 5 VDC supply for analog, Hall-effect,..
APS21024
Microbot APS Development Kit complete with autopliot programming dongle, second ( ground station radio modem ) and antennas...
APSN
Air purge collar for PyroMini -151, -201, -301 and CF models. The air purge collar is used to keep dust, fumes, moisture, and other contaminants away from the lens. It must be screwed fully onto the sensing head. Air flows into the 1/8 BSP fitting and out of the front..
APSW
Air purge collar for PyroMini -21 models. The air purge collar is used to keep dust, fumes, moisture, and other contaminants away from the lens. It must be screwed fully onto the sensing head. Air flows into the 1/8 BSP fitting and out of the front aperture. Air flow should..
AV-DSP
Air flow sensor, insertion type, range 0-4, 0-8, 0-16, 0-32 metres per second, user selectable via dip switches, output 4-20mA or 0-10vDC, user selectable, accuracy +/-3%. IP 65 weatherproof. probe 240mm x 19mm diameter.
The AV-DSP unit has been replaced by the new AV-622...
2523146
Waterproof 8-pin plug connector for the following Kipp & Zonen equipment. SMP Pyranometers, SGR Pyrgeometers, SUV Radiometers, CMP Pyranometers with PT100 output, CGR3 and CGR4 with PT100 output, CHP1, CNR4, UVS Radiometers and CSD3 Sunshine Duration Sensors...
820KCG13DO
CG-3DO ClickNGo Module, 3 Digital Output Module. Size 1 Module with three 5V Outputs. Operating Temp -20 to +60°C, 80%RH. Dimensions: 53.8 x 10.6 x 22.2mm, Weight: 10g. IP50 when installed in controller...
GL7-HV
2 Channel High Voltage Measurement Module for GL7000. Measurement range: 2V and 1000V full scale across 9 programmable settings. Sampling rate: 1s to 1hr. BNC connector connection to 2 isolated input channels with simultaneous sampling. Modules has an in-built RAM memory for up to 2 million samples...
GS-LXUV
GS-LXUV Illuminance and Ultra Violet intensity measurement. Illuminance Range: 0 to 200 kLux, UV intensity Range: 0 to 30mW/cm² with a 1ms response time. Also allows for the calculation of accumulated Illuminance and UV intensity. Accumulated illuminance 0 to 99,999kLuxh. 16 Byte record length, 111 days logging to internal memory..
AVT-D
AVT-D, Air Velocity Transmitter with 2 outputs for flow velocity, range 0-2, 0-10 or 0-20M/S and air temperature range 0-50 C, with 10V or 4-20mA outputs. With integral LCD display. Power supply 24vDC/AC, ABS housing and stainless steel probe...
B-537
Extension terminal base set..
B-538
20 channel extension terminal set..