5131B1A
Single channel 2-wire programmable ATEX transmitter with a 7.5-35vDC power supply. Suitable for RTD, TC, R and mV Input and 4-20mA output...
60990002
½" BSP Inlet and Outlet Pipe Set for F.Core Flow Sensor...
610-12
Replacement Membrane Kit for Dissolved Oxygen Sensors..
6185 Loop Powered Isolator
The 6185 is a loop powered isolator suitable for the galvanic separation of analogue current signals with a straight 1:1 conversion of 0-20mA inputs. The 6185 is available in single, dual and four channel versions with a slimline 3185 series available in single and dual channel versions, all with no..
6313888
Replacement Combustible sensor for BM25. Range 0-100% LEL...
6313962
4 Relay module for the MX32 v2 & MX43 Gas Controllers. Output module includes 4 relay outputs with 2 additional logic inputs. MX32 v2 can manage up to 16 external relays and the MX43 up to 24 external relays...
6331B2A
Intrinsically safe 2-Wire programmable transmitter with a 7.2-28vDC power supply. Single channel unit for PT100/PT1000, Ni100 or Resistance input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6333B1A
Intrinsically safe 2-Wire programmable transmitter with a 8-28vDC power supply. Single channel unit for PT100/PT1000, Ni100 or Resistance input, producing a 4-20mA output. Can be mounted vertically or horizontally on a DIN rail...
6334B2A
Intrinsically safe 2-Wire programmable transmitter with a 7.2-35vDC power supply. Single channel unit for TC or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6335A2B
2-Wire programmable transmitter with HART Protocol and an 8-35vDC power supply. Dual channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6335D2A
Intrinsically safe 2-Wire programmable transmitter with HART Protocol and an 8-28vDC power supply. Single channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6337D2A
PR6337D Intrinsically safe 2-Wire programmable transmitter with HART 7 Protocol and an 8-28vDC power supply. Single channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6451441
2 Channel Input Card for the MX52 Gas Detection Control Unit. Suitable for 2 x 340mA Wheatstone bridge gas sensor inputs...
7000-AMM
AP-7000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-7000, or AP-6000, Aquaprobe sensor..
7000-CAL
AP-7000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 7000-CAL is designed for use with the AP-6000, or AP-7000, Aquaprobe sensor with pH probe...
7000-CHL
AP-7000 Chloride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-19,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). The 7000-CHL is designed for use with the AP-6000, or AP-7000, Aquaprobe sensor..
7000-CPHYLL
AP-7000 Chlorophyll Electrode with 2 Auto-Range scales 0-99.99 µg/L or 100-500 µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L...
7000-FLU
AP-7000 Fluoride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 7000-FLU is designed for use with the AP-7000, or AP-6000 Aquaprobe sensor with pH probe. Readings may be affected by..
7000-NIT
AP-7000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 7000-NIT is designed for use with the AP-6000, or AP-7000 Aquaprobe sensor with pH probe...
7000-TURB
AP-7000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale...
8032204022
N322 Electronic Thermostat for Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts Thermocouple (Type J, K or T) Input. Measurement..
820KCG00DK
N20K48 Dock Accessory. Dock attaches to the back of the N20K48 Modular Controller and can hold up to 8 'Size 1' ClickNGo Modules, 4 'Size 2' ClickNGo Modules and 2 'Size 4' ClickNGo Modules...
825-170
RFX Meat Thermometer. Includes the following: 1 RFX Meat Thermometer, Thermometer Charging Block and Probe Rings...
877163
Stainless Steel Protective Cover for Next Generation 40/40 SharpEye Flame Detectors. Protects the detector from extreme weather conditions, such as heavy snow and heavy rain...