6313888
Replacement Combustible sensor for BM25. Range 0-100% LEL...
6313962
4 Relay module for the MX32 v2 & MX43 Gas Controllers. Output module includes 4 relay outputs with 2 additional logic inputs. MX32 v2 can manage up to 16 external relays and the MX43 up to 24 external relays...
6331B2A
Intrinsically safe 2-Wire programmable transmitter with a 7.2-28vDC power supply. Single channel unit for PT100/PT1000, Ni100 or Resistance input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6333B1A
Intrinsically safe 2-Wire programmable transmitter with a 8-28vDC power supply. Single channel unit for PT100/PT1000, Ni100 or Resistance input, producing a 4-20mA output. Can be mounted vertically or horizontally on a DIN rail...
6334B2A
Intrinsically safe 2-Wire programmable transmitter with a 7.2-35vDC power supply. Single channel unit for TC or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6335A2B
2-Wire programmable transmitter with HART Protocol and an 8-35vDC power supply. Dual channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6335D2A
Intrinsically safe 2-Wire programmable transmitter with HART Protocol and an 8-28vDC power supply. Single channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6337D2A
PR6337D Intrinsically safe 2-Wire programmable transmitter with HART 7 Protocol and an 8-28vDC power supply. Single channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6451441
2 Channel Input Card for the MX52 Gas Detection Control Unit. Suitable for 2 x 340mA Wheatstone bridge gas sensor inputs...
7000-AMM
AP-7000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-7000, or AP-6000, Aquaprobe sensor..
7000-CAL
AP-7000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 7000-CAL is designed for use with the AP-6000, or AP-7000, Aquaprobe sensor with pH probe...
7000-CHL
AP-7000 Chloride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-19,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). The 7000-CHL is designed for use with the AP-6000, or AP-7000, Aquaprobe sensor..
7000-CPHYLL
AP-7000 Chlorophyll Electrode with 2 Auto-Range scales 0-99.99 µg/L or 100-500 µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L...
7000-FLU
AP-7000 Fluoride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 7000-FLU is designed for use with the AP-7000, or AP-6000 Aquaprobe sensor with pH probe. Readings may be affected by..
7000-NIT
AP-7000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 7000-NIT is designed for use with the AP-6000, or AP-7000 Aquaprobe sensor with pH probe...
7000-TURB
AP-7000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale...
8032204022
N322 Electronic Thermostat for Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts Thermocouple (Type J, K or T) Input. Measurement..
820KCG00DK
N20K48 Dock Accessory. Dock attaches to the back of the N20K48 Modular Controller and can hold up to 8 'Size 1' ClickNGo Modules, 4 'Size 2' ClickNGo Modules and 2 'Size 4' ClickNGo Modules...
825-170
RFX Meat Thermometer. Includes the following: 1 RFX Meat Thermometer, Thermometer Charging Block and Probe Rings...
877163
Stainless Steel Protective Cover for Next Generation 40/40 SharpEye Flame Detectors. Protects the detector from extreme weather conditions, such as heavy snow and heavy rain...
8803116430
RHT-DM-485-LCD 150mm Duct mounted Humidity and Temperature transmitter with integrated LCD Display...
8804111000
RHT Climate-DM-150S Duct Mounted Temperature and Relative Humidity Transmitter with 150mm Stainless Steel Probe. Two analogue outputs, configurable as 4-20mA or 0-10V for any sensor or calculated psychromatic readings. Two configurable alarm outputs. Temperature Range -40 to +100°C, Relative Humidity Range 0 to 100%RH. Power Supply 12 to 32vDC. USB..
8807000000
TxIsoPack programmable 2-wire isolated head mounted temperature transmitter. Suitable for Thermocouples (Type J, K, T, E, N,R, S, B), PT100 (2,3 or 4-Wire) and 0-50mV inputs with configurable 4-20mA or 20-4mA output. Integrated mini USB port for configuration of input type and output range. The TxIsoPack is suitable for head..
8812190950
Colour 2.4" HMI display for FieldLogger data logger for local indication or configuration. Allows parameter checking and configuration plus shows current values, historical charts and indicates status and alarms information. Local or remote installation with RS485 communication...