0376900-202
SGR4-A Smart Pyrgeometer. Silicon meniscus dome with hard carbon coating and infrared window materials to absorb short-wave radiation. Integrated leveling. Sun shield. Spectral range 4400-50,000nm, response time less than 18 sec (95%), temperature dependence of sensitivity less than 1% (-20 to +50°C). Operating temperature -40 to +80°C. 2-wire RS485 Modbus..
1-Wire Dual Channel Analogue Modules
1-Wire Dual-Channel Analogue Input Modules covering 0-20mA, 0-10V and 0-60V signals inputs with screwless terminal connections. The TSA202 is a dual-channel module for 0-20mA and 0-10V inputs, converting analogue current signals from industrial sensors into digital data. In contrast, the TSA202-60 is a dual-channel module suitable for 0-60V inputs. Both..
18106880-1
Hard leather case without window for aspirated MX6...
1957-0500-60-101
MaxiMet GMX500 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and Direction correcting for..
1957-0501-60-101
MaxiMet GMX501 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and Direction..
1957-0531-60-101
MaxiMet GMX531 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Rainfall, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and..
1957-0550-60-101
MaxiMet GMX550 Compact Weather Station with GPS & Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill,..
1957-0551-60-101
MaxiMet GMX551 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Pulse Input for Rainfall, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True..
1957-0560-60-101
MaxiMet Marine GMX560 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, 6-Axis Compass Heading, GPS Location, Heading and Speed. Compass allows compensations for tilt and provides pitch & roll data. Derived Parameters: Average Wind Speed & Direction, Corrected..
1957-0600-60-101
MaxiMet GMX600 Compact Weather Station with GPS and Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Precipitation, 2-Axis Compass Heading, GPS Location, Heading and Speed. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, True Wind Speed and Direction correcting..
20/20MI-32SF
20/20MI Sharpeye Mini Short Range IR3 Flame Detector with connector output. Sensitive Range: 2.5 to 10m. Field of View: 100° Horizontal & 100° Vertical. Response Time: 5 seconds, adjustable up to 30 seconds. Automatic and Manual Built-In-Test. Output: Relays (SPST 30vDC @ 2A), 4-20mA (Fault = 0mA; BIT Fault =..
3117
PR3117 Slim Series Bipolar Isolated Converter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of bipolar inputs to unipolar outputs. Input options of 10mA, 20 mA, 5V or 10V with unipolar mA or V outputs. Response time: less than 7 ms, Accuracy 0.05% of span. Power Supply:..
3186B2
3186B2 Dual Channel 2-Wire Current Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of active current input signals within the range 3.8-20.5 mA, Response time: less than 5 ms, Accuracy 0.05% of span. Loop powered via the output loop, voltage drop <3V with a 10uA..
420.0210
ThermoAir Pro Omnidirectional (MA) Thermal-Electric Omnidirectional Anemometer. Air Velocity Range: 0.015-1m/s with a 4-20mA Output. Accuracy ±1.0% of full scale. Sensing head surrounded by a removable 110mm diameter protective cage, handle 15mm diameter, probe length 270mm. The probe measures the flow velocity from all directions in the measuring plane perpendicular..
5106BB-B
Hart Transparent Repeater, 2 Channel, ATEX II (1) GD, 4...20mA, 24...230 VAC/DC..
5115B2
5115B2 Ex Signal Calculator. Redundancy measurement of 2 inputs, duplication of input signals or signal calculations of inputs. Unit will accept mA, V or mV input signals. Power supply 21.6 - 253 vAC or 19.2 - 300vDC with 0-20mA or 0-10vDC output...
6513566
OLC10 TWIN fixed gas detector with Wheatstone Bridge output for flammable gases. Range 0-100%LEL for CH4, C3H8, C4H10 or Hydrogen. Two OLC10 TWIN sensors can be linked to a single channel on gas controller. Operating Range: -10 to +45°C, 0 to 95%RH. Dimensions: 118 x 126 x 58mm, IP65 ABS..
6513653
OLCT80D Wireless Transmitter with LCD display for flameproof remote sensor with 15m cable, sensor block available separately. The OLCT80 transmitter is supplied with 6 XP sealing plugs (4x M20 and 2 x M25), suitable cable gland kits are available separately to allow access to 2 auxiliary inputs (4-20mA or digital..
8032203322
N322 Electronic Thermostat for Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C..
9106A HART Transparent Repeater
9106A is a 1- or 2-channel isolated 1:1 repeater. The device supplies 2-wire SMART transmitters and can also be used for 2-wire SMART current sources. HART & BRAIN protocols are supported and are transferred bi-directionally...
9106A2B
Dual channel isolated HART transparent repeater, 2 x 4-20mA input, 2 x 4ƒ-20 mA output, power supply 19.2 - 31.2, Uo=25.6 V, SIL2 certified to IEC 61508..
9106B2B
Dual channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4…20 mA output, power supply 19.2 - 31.2, Uo= 25.6V, SIL2 certified to IEC 61508..
9107AB-U9
PR 9107AB-U9 Dual Channel HART Transparent Driver. Signal Splitter (1 In, 2 Out), or Dual Channels, Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area or in Zone 2/Class I, Division 2, Groups A, B, C or D. SIL2 Certified, plus UL913 ATEX, IECEx,..
9107BB-U9
PR 9107BB Intrinsically Safe Single Channel HART Transparent Driver. Signal Splitter (1 In, 2 Out), or Dual Channels, Input: 4-20mA. Output: 4-20mA. Galvanic isolation of inputs and outputs.Can be mounted in safe area, or in Zone 2/Class I, Division 2 and transmit signals to Zone 1 0, 1, 2 and..