3109-N
3109 Slim Series Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of a single 0/2-10V, 0/1-5V and 0/4-20mA input signal to individually configurable 0/2-10V, 0/1-5V and 0/4-20mA on two output channels. The 3109 can also provide power supply and signal isolation to a 2 wire..
3225B-N
3225B Slim Series Universal Converter suitable for use in Hazardous Areas. Frequency Input: 0.001Hz to 100kHz. Output: 1 Relay Output (Setpoint, Window, Sensor error, Latch, Power and Off). Power Supply: 24vDC ±30%, via terminals only. 6mm Slimline housing...
400.0310
MC 4.0 ManoAir Manometer Touchscreen Display. Range ±20kPa. The MC 4.0 can measure absolute or differential pressures, filter and pitot tubes for ventiliation ducts. Measurement Range ±20kPa. Resolution: 0.01kPa, Accuracy: <100 Pa ± 0.03kPa + ±0.10%FS >100 Pa ±0.01kPa + ±0.10%FS. 3.2" TFT Touchscreen Display, 2Hz measurement rate, internal logger..
420.0201
ThermoAir Pro Directional (mA) Thermal-Electric Directional Anemometer. Air Velocity Range: 0.015-5m/s with a 4-20mA Output. Accuracy ±1.0% of full scale. Sensing head 8mm diameter, handle 15mm diameter, probe length 300mm. The required diameter of the retraction opening for the probe is 9mm. The sensor can be used at temperatures from..
5105B EX-Isolated Driver
1- or 2-channel version ~ 3- / 5-port 3.75 kVAC galvanic isolation Driver for Ex area 20 programmable measurement ranges Universal supply by AC or DC..
8032203024
N322 Electronic Thermostat for Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C..
8809101605
Slimline WL320 Submersible Hydrostatic Level Transmitter. Depth Range 1.6mH2O. 2-Wire Loop Powered 4-20mA Output with a 12-36vDC Power Supply. 5m Polyurethane (PUR) Cable with Ventilation Tube. Stainless Steel Sensor with 140mm Body Length and 19mm Diameter...
8812130400
FieldLogger data logger with 512k internal memory. 8 Universal Inputs, 2 Relay Outputs, 8 Digital I/O's and Mini USB Interface for PC Interface for programming, monitoring and downloading. Power Supply: 24vDC. Basic model, with USB host for data downloading to USB memory stick and a single RS485 interface for up..
9202B ATEX Pulse Isolator
ATEX approved pulse isolator module, for NAMUR sensors and switch inputs, single or dual channel, SIL 2 certified, programmed via detachable front programming unit 4501. With relay or NPN outputs. DIN rail mounting, power supply 19.2-31.2 VDC, input range 0-5KHz, output 0-20Hz. tHE 9202B can be mounted in the safe..
9203A2A2
Solenoid and alarm driver, 1 channel driver output, 1 NPN input, SIL 2, high current version (50-60 mA), 19.2 - 31.2 VDC supply. 1 relay output...
AC-RSCT-19CM
Rogowski coil 19 cm / 7.48 inches diameter..
AP-2000-D-PACKAGE-BT
The AP-2000 Aquaprobe Package, AP-2000-D-PACKAGE, contains: BlueLink Adaptor; Aquaprobe AP-2000-D Probe, supplied with Optical Dissolved Oxygen, Conductivity, pH, ORP, TDS, SSG, Resistivity, Salinity, Temperature and Depth sensors; a 3m tough Cable with Connectors at both ends; Calibration Solutions; and various accessories all supplied in a Rugged Carry Case. The AP-2000..
AP-700-D-PACKAGE-BT
The AP-700 Aquaprobe Package, AP-700-D-PACKAGE-BT, contains: Bluelink Adaptor; Aquaprobe AP-700-D Probe, supplied with Galvanic Dissolved Oxygen, Conductivity, pH, ORP, TDS, SSG, Resistivity, Salinity, Temperature and Depth sensors; a 3m tough Cable with Connectors at both ends; Calibration Solutions; and various accessories all supplied in a Rugged Carry Case. The Galvanic..
AP-800-D-PACKAGE-BT
The AP-800 Aquaprobe Package, AP-800-D-PACKAGE-BT, contains: Bluelink Adaptor; Aquaprobe AP-800-D Probe, supplied with Galvanic Dissolved Oxygen, Conductivity, pH, ORP, TDS, SSG, Resistivity, Salinity, Optical Turbidity, Temperature and Depth sensors; a 3m tough Cable with Connectors at both ends; Calibration Solutions; and various accessories all supplied in a Rugged Carry Case...
B-563SL
20 Channel Screwless Input Terminal, Multi-Input Type. Suitable for the GL860 data logger...
CA-12/0040D
Solar Mounting Kit for two 40W Ameresco Solar Panel U-bolts are required for pole mounting..
CCDDT-5T-LOADCAP
Spherical Load Cap for CCDDT Load Cells. Capacity up to 5 Tonnes. Dimensions: Diameter 31mm, Height 10mm, Internal Radius 30mm..
EL-PDF-1-002
EasyLog PDF Temperature Logger for Frozen Goods. Temperature Range: -30 to +60°C. Alarm Thresholds: Low: -20°C; High -16°C. Logging Interval: 10 Mins, Internal Memory: 32,600 readings (220 days logging). Battery Life: 12 Months. Start/Stop and Status button to light LEDs in the event of any alarm conditions. No software required...
HITEMP140-TSK-5.25
Submersible Datalogger with a PTFE thermal barrier for extreme temperature logging. Temperature Range: -200 to +250°C from a 100 ohms Platinum RTD with a resolution of 0.01°C. Internal Memory 65,536 readings, sample rate 1 second up to 24 hours and 2 year battery life. Operating Environment -40 to +140°C, (short-term..
HITEMP140-TSK-7
Submersible Datalogger with a PTFE thermal barrier for extreme temperature logging. Temperature Range: -200 to +250°C from a 100 ohms Platinum RTD with a resolution of 0.01°C. Internal Memory 65,536 readings, sample rate 1 second up to 24 hours and 2 year battery life. Operating Environment -40 to +140°C, (short-term..
LEO1EI-1-30BAR
LEO1EI Digital Manometer suitable for Hazardous Areas. Range -1 to 30 Bar with accuracy of 0.2% and peak reading mode at 5kHz. Pressure connection 1/4 inch BSP male connection, operating temperature 0 to 50 C, internal battery for up to 1,000 hours operation (150 hours in peak mode) and IP65..
LPMS-STRAP-47CM
Strap for LPMS-B2 Bluetooth Sensors. Strap Length: 47cm. Suitable for Sensors Located on the Head or Thigh...
MF96412
Nemo 96HDLe Multi-function panel mounted power meter suitable for single or 3 phase networks, 3 or 4-wires. Single-phase Input: 50-290V. Three-phase Input: 80-500V (phase-phase). Current Inputs 1A or 5A CTs. Meter has 1 slot for a plug in module. Auxiliary Power Supply: 16-60vDC. Backlit LCD display with 8/12mm digits. Dimensions..
MX16-A-003-0-0-0
MX16 Gas Detection Controller configured for 4-20mA Analogue Input Gas Detector. Pre-Configured for Hydrogen (H2) with a range of 0-100%LEL. 2 Alarm levels (Al1, Al2) + 1 fault, with Dry Contact Relays. LCD back-lit display. IP55 Enclosure with 3 x M16 and 2 x M20 cable glands. Dimensions 265 x..