1957-0531-60-001
MaxiMet GMX531 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute..
1957-0550-60-001
MaxiMet GMX550 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index,..
1957-0551-60-001
MaxiMet GMX551 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill,..
1957-0560-60-001
MaxiMet Marine GMX560 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed and Direction, Air Temperature, Relative Humidity, Barometric Pressure and 6-Axis Compass. Compass allows compensations for tilt and provides pitch & roll data. Outputs: RS232, 422, 485 (ASCII), SDI-12, NMEA, MODBUS. Power Supply: 10-30vDC (Consumption 425mA @ 12vDC)...
1957-0600-60-001
MaxiMet GMX600 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Precipitation and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute Humidity, Air..
20/20MI-31SF
20/20MI Sharpeye Mini Short Range IR3 Flame Detector with cable output. Sensitive Range: 2.5 to 10m. Field of View: 100° Horizontal & 100° Vertical. Response Time: 5 seconds, adjustable up to 30 seconds. Automatic and Manual Built-In-Test. Output: Relays (SPST 30vDC @ 2A), 4-20mA (Fault = 0mA; BIT Fault =..
3109
3109 Slim Series Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of a single 0/2-10V, 0/1-5V and 0/4-20mA input signal to individually configurable 0/2-10V, 0/1-5V and 0/4-20mA on two output channels. The 3109 can also provide power supply and signal isolation to a 2 wire..
3186B1
3186B1 Single Channel 2-Wire Current Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of active current input signals within the range 3.8-20.5 mA, Response time: less than 5 ms, Accuracy 0.05% of span. Loop powered via the output loop, voltage drop <3V with a 10uA..
321.01.55.15.05.1.4
PTM/N submersible depth sensor, range 0 to 1 BarG (0-10mWG). Closed version with standard Viton seals and 12m PUR cable connection. Output - 2-wire, 4-20mA. Accuracy ±0.25%. Compensated temperature range -5 to 50°C..
3225B
3225B Slim Series Universal Converter suitable for use in Hazardous Areas. Frequency Input: 0.001Hz to 100kHz. Output: 1 Relay Output (Setpoint, Window, Sensor error, Latch, Power and Off). Power Supply: 24vDC ±30%, via power rail or terminals. 6mm Slimline housing...
400.0301
MC 4.0 ManoAir Manometer Display. Range ±20kPa. The MC 4.0 can measure absolute or differential pressures, filter and pitot tubes for ventiliation ducts. Measurement Range ±20kPa. Resolution: 0.01kPa, Accuracy: <100 Pa ± 0.03kPa + ±0.10%FS >100 Pa ±0.01kPa + ±0.10%FS. 3.2" TFT-Display, 2Hz measurement rate, internal logger for up to..
420.0200
ThermoAir Pro Directional (mA) Thermal-Electric Directional Anemometer. Air Velocity Range: 0.015-1m/s with a 4-20mA Output. Accuracy ±1.0% of full scale. Sensing head 8mm diameter, handle 15mm diameter, probe length 300mm. The required diameter of the retraction opening for the probe is 9mm. The sensor can be used at temperatures from..
5106BB-A
Hart Transparent Repeater, 1 Channel, ATEX II (1) GD, 4...20mA, 24...230 VAC/DC..
5115B1
5115B1 Ex Signal Calculator. Redundancy measurement of 2 inputs, duplication of input signals or signal calculations of inputs. Unit will accept RTD, Ohm, TC, mV input signals. Power supply 21.6 - 253 vAC or 19.2 - 300vDC with 0-20mA or 0-10vDC output...
5116B
5116B ATEX Approved, Universal, programmable transmitter, 24~240VAC/DC, 2 Relays and retransmit output...
5531B
4-digit LCD display 48 x 96 mm ~ Loop-powered, Easy scalable from front keys, Backlight . Intrinsically safe Atex II 1G. IP65 enclosure from front..
6511157
Universal Charger for BM25 / charging time 4h30 with Power Supply Cord..
6513559
OLC10 fixed gas detector with Wheatstone Bridge output for flammable gases. Range 0-100%LEL for CH4, C3H8, C4H10 or Hydrogen. 3-wire connection, max cable length 300m. Operating Range: -10 to +45°C, 0 to 95%RH. Dimensions: 118 x 126 x 58mm, IP66 ABS housing with M16 gland. ATEX II 3 G -..
6513646
OLCT80 Wireless Transmitter with LCD display for flameproof local sensor, sensor block available separately. The OLCT80 transmitter is supplied with 6 XP sealing plugs (4x M20 and 2 x M25), suitable cable gland kits are available separately to allow access to 2 auxiliary inputs (4-20mA or digital state), 3 SPDT..
8032203022
N322 Electronic Thermostat for Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C..
8809101005
Slimline WL320 Submersible Hydrostatic Level Transmitter. Depth Range 1mH2O. 2-Wire Loop Powered 4-20mA Output with a 12-36vDC Power Supply. 5m Polyurethane (PUR) Cable with Ventilation Tube. Stainless Steel Sensor with 140mm Body Length and 19mm Diameter...
8812130000
FieldLogger data logger with 512k internal memory. 8 Universal Inputs, 2 Relay Outputs, 8 Digital I/O's and Mini USB Interface for PC Interface for programming, monitoring and downloading. Power Supply: 100-240vAC, with 24vDC auxiliary supply for connected devices. Basic model, with USB host for data downloading to USB memory stick..
9106A2A
Single channel isolated HART transparent repeater, 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, Uo=25.6 V, SIL2 certified to IEC 61508..
9106B2A
Single channel isolated HART transparent repeater ATEX approved I.S., 4-20mA input, 4ƒ-20 mA output, power supply 19.2 - 31.2, Uo= 25.6V, SIL2 certified to IEC 61508..