0374900-200
SMP 3 Smart Pyranometer with 4-20mA output. Single 4mm glass dome. Integrated leveling. Sun shield. Spectral range 300 - 2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Digital output range -200 to 2,000W/m². Analogue output range..
0374905-200
SMP 10 Smart Pyranometer with 4-20mA output. Double 2mm glass dome. Integrated leveling. Sun shield. Spectral range 285 - 2800nm, response time less than 2 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Analogue output range 0 to 1600Wm², Digital output range..
0374920-200
SMP 6 Smart Pyranometer with 4-20mA output. Two, 2mm thick, high quality concentric domes. Integrated levelling. Sun shield. Spectral range 285-2800nm, response time less than 12 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire RS485 Modbus and 4-20mA output. Analogue output range 0 to 1,600Wm², Digital output..
0374940-200
SMP22 Smart Pyranometer with a configurable 4-20mA output. Secondary standard pyranometer with a 32-junction thermopile sensing element under two, 2mm thick, high quality concentric domes. Integrated leveling. Sun shield. Spectral range 250 - 3500nm, response time less than 2 sec (95%), Operating temperature -40 to +80°C. Thermopile detector. 2 wire..
0376900-200
SGR4-A Smart Pyrgeometer. Silicon meniscus dome with hard carbon coating and infrared window materials to absorb short-wave radiation. Integrated leveling. Sun shield. Spectral range 4400-50,000nm, response time less than 18 sec (95%), temperature dependence of sensitivity less than 1% (-20 to +50°C). Operating temperature -40 to +80°C. 2-wire RS485 Modbus..
1-Wire Analogue Input Transmitters
1-Wire Analogue Input Transmitters covering 0-20mA and 0-60V signals inputs with RJ11 connectors for easier daisy-chaining. The TSA200 is a 1-Wire current loop transmitter for 0-20mA/4-20mA inputs, converting analogue current signals from industrial sensors into digital data. In contrast, the TSV200-60i is a 1-Wire DC voltage sensor, designed to measure..
10130007
ComNav G1 GNSS Satellite Compass with G3 Colour Display. Output: NMEA2000. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 45° per second. Power Supply 10 to 36vDC (240mA @ 12vDC). The G1 contains a ComNav receiver..
111-761
P11 Protected Bulb pH Electrode for a pH range of 0-14. Combination electrode with a Silver/Silver Chloride, single porous Teflon junction. Eo point 0 to +/-25mV. Shaft dimensions (approx) 12mm diameter and 120mm length. BNC connector with 1m cable. Operating temperature 0 to 100 C. Suitable for pH monitoring where..
1957-0500-60-001
MaxiMet GMX500 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute Humidity, Air Density..
1957-0501-60-001
MaxiMet GMX501 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute Humidity,..
1957-0531-60-001
MaxiMet GMX531 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute..
1957-0550-60-001
MaxiMet GMX550 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index,..
1957-0551-60-001
MaxiMet GMX551 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Solar Irradiance, Pulse Input for Rainfall and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill,..
1957-0560-60-001
MaxiMet Marine GMX560 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed and Direction, Air Temperature, Relative Humidity, Barometric Pressure and 6-Axis Compass. Compass allows compensations for tilt and provides pitch & roll data. Outputs: RS232, 422, 485 (ASCII), SDI-12, NMEA, MODBUS. Power Supply: 10-30vDC (Consumption 425mA @ 12vDC)...
1957-0600-60-001
MaxiMet GMX600 Compact Weather Station with Heating. Measured Parameters: Relative Wind Speed, Wind Direction, Air Temperature, Relative Humidity, Barometric Pressure, Precipitation and 2-Axis Compass Heading. Derived Parameters: Average Wind Speed & Direction, Corrected Direction, Gust Speed & Direction, Dew Point, Wet Bulb Temperature, Wind Chill, Heat Index, Absolute Humidity, Air..
20/20MI-31SF
20/20MI Sharpeye Mini Short Range IR3 Flame Detector with cable output. Sensitive Range: 2.5 to 10m. Field of View: 100° Horizontal & 100° Vertical. Response Time: 5 seconds, adjustable up to 30 seconds. Automatic and Manual Built-In-Test. Output: Relays (SPST 30vDC @ 2A), 4-20mA (Fault = 0mA; BIT Fault =..
3109
3109 Slim Series Isolated Converter/Splitter suitable for use in ATEX Zone 2 Environments. Isolation and conversion of a single 0/2-10V, 0/1-5V and 0/4-20mA input signal to individually configurable 0/2-10V, 0/1-5V and 0/4-20mA on two output channels. The 3109 can also provide power supply and signal isolation to a 2 wire..
3186B1
3186B1 Single Channel 2-Wire Current Isolator suitable for use in ATEX Zone 2 Environments. Isolation and 1:1 conversion of active current input signals within the range 3.8-20.5 mA, Response time: less than 5 ms, Accuracy 0.05% of span. Loop powered via the output loop, voltage drop <3V with a 10uA..
321.01.55.15.05.1.4
PTM/N submersible depth sensor, range 0 to 1 BarG (0-10mWG). Closed version with standard Viton seals and 12m PUR cable connection. Output - 2-wire, 4-20mA. Accuracy ±0.25%. Compensated temperature range -5 to 50°C..
3225B
3225B Slim Series Universal Converter suitable for use in Hazardous Areas. Frequency Input: 0.001Hz to 100kHz. Output: 1 Relay Output (Setpoint, Window, Sensor error, Latch, Power and Off). Power Supply: 24vDC ±30%, via power rail or terminals. 6mm Slimline housing...
400.0301
MC 4.0 ManoAir Manometer Display. Range ±20kPa. The MC 4.0 can measure absolute or differential pressures, filter and pitot tubes for ventiliation ducts. Measurement Range ±20kPa. Resolution: 0.01kPa, Accuracy: <100 Pa ± 0.03kPa + ±0.10%FS >100 Pa ±0.01kPa + ±0.10%FS. 3.2" TFT-Display, 2Hz measurement rate, internal logger for up to..
420.0200
ThermoAir Pro Directional (mA) Thermal-Electric Directional Anemometer. Air Velocity Range: 0.015-1m/s with a 4-20mA Output. Accuracy ±1.0% of full scale. Sensing head 8mm diameter, handle 15mm diameter, probe length 300mm. The required diameter of the retraction opening for the probe is 9mm. The sensor can be used at temperatures from..
5106BB-A
Hart Transparent Repeater, 1 Channel, ATEX II (1) GD, 4...20mA, 24...230 VAC/DC..
5115B1
5115B1 Ex Signal Calculator. Redundancy measurement of 2 inputs, duplication of input signals or signal calculations of inputs. Unit will accept RTD, Ohm, TC, mV input signals. Power supply 21.6 - 253 vAC or 19.2 - 300vDC with 0-20mA or 0-10vDC output...