Description
Connect directly to any data logger input channel; no external power required.
- Rugged polyamide DIN mount case.
- Designed for industrial environments
- Self powered.
Specifications – PACE AC Voltage Sensors | |
Frequency Range | SV300: 48 – 400 Hz SV600: 48 – 65 Hz |
Voltage Overload | Full scale rating |
Accuracy (50 – 60 Hz) | ±0.25% of F.S. (includes effects of linearity 10% to 100% of F.S.) |
SV300 Only: Accuracy @ 400Hz | ±0.50%FS (includes effects of linearity 10% to 100% of F.S.) |
Temperature Effect | ±1.0% (-20 to 65°C) |
Output Ripple | Less than 1% full scale |
Response Time (99%) | 400 milliseconds |
Connections | Recessed screw terminals for input and output wiring |
Burden | 2.0 VA |
Size | 3.7″H x 3.1″W x 1″D |
IMPORTANT: The AC Voltage Sensors must be mounted in a suitable panel or enclosure and the input & output terminals must be wired. A suitable ABS enclosure is available for either the SV300 or SV600.
WARNING: SHOCK OR INJURY HAZARD: Disconnect AC Power Source before wiring AC Sensor inputs.
TheSV600 Sensor includes an external potential transformer which also must be mounted and wired in a suitable panel or enclosure. External transformer size: 1.6″H x 2.8″W x 2″D.
Use the SV300 to monitor and record 24, 120 and 240 Vac circuits; use the SV600 to monitor and record 24, 120, 240 and 480 Vac circuits.
Part No | Range (Frequency) |
SV300 | 0-300vAC (48 – 400 Hz) |
SV600 | 0-600vAC (48 – 65 Hz) |
For a more flexible AC voltage sensor, try the DIN Rail Mounted AC Voltage Transducer