Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR5450D Profibus Transmitter

Home / Our Brands / PR Electronics / PR Temperature Transmitters / Head Mounted / 2-Wire Profibus Transmitters / PR5450D Profibus Transmitter

PR5450D Profibus Transmitter

The PR 5450D is an intrinsically safe, head-mounted PROFIBUS PA temperature transmitter for hazardous-area measurement applications. It accepts RTD, thermocouple, potentiometer, linear resistance and bipolar millivolt inputs, with single or true dual-input options. Designed for DIN form B sensor heads, it combines sensor signal conversion with digital communication, diagnostics and configuration through a compatible PROFIBUS PA network.

Hazardous-Area Measurement with International Approvals

The 5450D offers hazardous-area certification covering multiple markets, including ATEX, IECEx and North American approvals. This makes it an option for equipment manufacturers and process installations requiring a common transmitter platform across different destinations.

Approved installation arrangements include specified hazardous gas and dust areas. Its conformity with the FISCO concept supports integration into suitably designed intrinsically safe fieldbus networks. The transmitter, sensor, enclosure and associated equipment must meet the applicable certification conditions.

Flexible Sensor Connections

The broad input selection accommodates temperature sensors and other supported electrical measurements. A single transmitter platform can therefore serve different measurement points by configuring the input type and operating parameters.

For suitable RTDs, Callendar–Van Dusen sensor matching allows individual calibration characteristics to be used. Custom linearisation provides additional flexibility where the input requires a defined conversion relationship.

Dual Inputs and Measurement Continuity

True dual-input operation allows two compatible sensors to connect to one transmitter. Available functions include individual readings, average and differential measurement, and minimum or maximum tracking.

Sensor redundancy supports continuity of measurement. Drift detection compares sensor readings and alerts the system when their difference exceeds a user-defined limit, helping maintenance teams investigate a potential sensor problem.

PROFIBUS PA Communication and Diagnostics

Supporting PROFIBUS PA Profile 4.0, the 5450D communicates process values and device status digitally over the fieldbus. The two-wire connection provides both power and communication.

Configuration and diagnostic access are available through compatible software and the appropriate device integration files. NAMUR NE107 diagnostic information supports identification of device conditions requiring attention.

Installation and Model Selection

The compact housing fits compatible DIN form B sensor heads, positioning conversion close to the measurement point. Galvanic isolation separates the sensor and fieldbus circuits, with a specified isolation test voltage of 2.5 kVAC.

Choose the input arrangement and measurement functions to match the sensors, then confirm fieldbus compatibility and the approvals required at the installation location. The 5450D is particularly relevant where a project requires international certification coverage beyond the ATEX approval offered by the 5450B.

Options

TypeVersionInputs
5450A: Zone 2 and zone 22 / Class I, Division 2, Groups A, B, C, D.
B: Zone 0, 1, 2 and zone 21, 22 including M1.
D: Zone 0, 1, 2 and zone 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D.

1: Single Input (4 Terminals)

2: Dual Input (7 Terminals)

Applications

Connect suitable RTD or thermocouple sensors to PROFIBUS PA systems in certified hazardous gas and dust installations.
Use a common transmitter platform across projects requiring ATEX, IECEx or North American certification, subject to the applicable approval conditions.
Compare two temperatures, calculate an average or configure sensor redundancy using compatible input arrangements.
Identify when sensor readings differ beyond a configured limit, helping maintenance teams investigate potential measurement problems.

Frequently Asked Questions

▶ Q: Which inputs does the 5450D support?
A: RTDs, thermocouples, potentiometers, linear resistance and bipolar millivolt signals.
▶ Q: Can it connect to two sensors?
A: Yes. Suitable configurations support individual readings, averaging, differential measurement, redundancy and drift detection.
▶ Q: Does it provide a 4–20 mA output?
A: No. Measurement values and device status are communicated digitally through PROFIBUS PA.
▶ Q: How is it configured?
A: Through fieldbus communication using compatible software and the appropriate device integration files.
▶ Q: Where is it mounted?
A: Inside a compatible DIN form B sensor head.
▶ Q: How does it differ from the 5450B?
A: The 5450D offers broader international hazardous-area certification coverage. The required approval depends on the installation location and conditions.

5450D1

5450D1

PR 5450D1 2-Wire Programmable Profibus PA Transmitters. Single Channel Input: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer 10 to 100kΩ. Output: Profibus PA. Accuracy ≤±0.05% of span. Response Time: <400ms. Power Supply 9-30vDC @ <352mW. 2.5kVAC Galvanic Isolation. Namur NE21, NE44, NE89 and NE107. Approvals: ATEX, IECEx, FM, CSA & INMETRO; NEPSI & EAC Certification. Operating Temp: -40 to +85°C.

£539.00
Add to Basket More Info
5450D2

5450D2

PR 5450D2 2-Wire Programmable Profibus PA Transmitters. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer 10 to 100kΩ. Output: Profibus PA. Accuracy ≤±0.05% of span. Response Time: <400ms. Power Supply 9-30vDC @ <352mW. 2.5kVAC Galvanic Isolation. Namur NE21, NE44, NE89 and NE107. Approvals: ATEX, IECEx, FM, CSA & INMETRO; NEPSI & EAC Certification. Operating Temp: -40 to +85°C.

£578.00
Add to Basket More Info
5909

5909

USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.

£240.00
Add to Basket More Info
8421

8421

DIN Rail mounting clip for head mount transmitters

£6.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000