Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR5450B Profibus Transmitter

PR 5450B HART Temperature Transmitter
Home / Our Brands / PR Electronics / PR Temperature Transmitters / Head Mounted / 2-Wire Profibus Transmitters / PR5450B Profibus Transmitter

PR5450B Profibus Transmitter

The PR 5450B is an intrinsically safe, head-mounted PROFIBUS PA temperature transmitter for industrial measurement in hazardous areas. It accepts RTD, thermocouple, potentiometer, linear resistance and bipolar millivolt inputs, converting sensor signals into digital process data. Single or true dual-input options allow the transmitter to handle individual measurements, temperature comparisons and sensor redundancy within a compatible DIN form B sensor head.

Intrinsically Safe Temperature Measurement

The 5450B carries ATEX approval for specified hazardous gas and dust environments, including permitted installations in Zones 0, 1 and 2, Zones 21 and 22, and mining applications under its certification conditions.

Conformity with the FISCO concept supports its use in suitably designed intrinsically safe PROFIBUS PA networks. The transmitter, fieldbus supply, sensor connections and enclosure must be selected together to meet the requirements of the installation.

Flexible Inputs and Sensor Matching

A broad choice of input types allows the 5450B to accommodate conventional temperature sensors and other supported electrical measurements. Sensor selection and measurement settings are configured to match the connected equipment.

For suitable RTDs, Callendar–Van Dusen coefficients allow the transmitter to use the characteristics of an individually calibrated sensor. Custom linearisation provides further flexibility for measurements requiring a defined relationship between the input and reported value.

Dual Inputs, Redundancy and Drift Detection

True dual-input operation supports two compatible sensors connected to one transmitter. Available functions include individual measurements, averaging, differential measurement and minimum or maximum tracking.

Sensor redundancy supports measurement continuity, while drift detection monitors the difference between readings. An alert is generated when that difference exceeds a configured limit, helping maintenance teams identify and investigate a potential sensor issue.

PROFIBUS PA Configuration and Diagnostics

The 5450B supports PROFIBUS PA Profile 4.0, transmitting measurement values and device status over the fieldbus connection. Power and communication share the two-wire bus.

Compatible configuration and asset-management software provides access to device parameters and diagnostics using the appropriate integration files. NAMUR NE107 diagnostic information helps the receiving system identify device conditions requiring attention.

PROFIBUS PA Configuration and Diagnostics

The 5450B supports PROFIBUS PA Profile 4.0, transmitting measurement values and device status over the fieldbus connection. Power and communication share the two-wire bus.

Compatible configuration and asset-management software provides access to device parameters and diagnostics using the appropriate integration files. NAMUR NE107 diagnostic information helps the receiving system identify device conditions requiring attention.

Options

TypeVersionInputs
5450A: Zone 2 and zone 22 / Class I, Division 2, Groups A, B, C, D.
B: Zone 0, 1, 2 and zone 21, 22 including M1.
D: Zone 0, 1, 2 and zone 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D.

1: Single Input (4 Terminals)

2: Dual Input (7 Terminals)

Applications

Connect suitable RTD or thermocouple sensors to a PROFIBUS PA system in ATEX installations, subject to certification conditions.
Use compatible dual sensors to compare two measurement points or calculate an average temperature.
Support measurement continuity and detect when sensor readings diverge beyond a configured limit.
Convert supported resistance, potentiometer and bipolar millivolt inputs into digital process data.

Frequently Asked Questions

▶ Q: Which sensors does the 5450B support?
A: RTDs, thermocouples, potentiometers, linear resistance and bipolar millivolt inputs.
▶ Q: Can it measure two sensors?
A: Yes. Compatible dual-input arrangements support individual readings, averaging, differential measurement, redundancy and drift detection.
▶ Q: Does it provide a 4–20 mA output?
A: No. It communicates measurement values digitally through PROFIBUS PA.
▶ Q: How is it configured?
A: Through fieldbus communication using compatible software and the appropriate device files.
▶ Q: Where does it fit?
A: Inside a compatible DIN form B sensor head.
▶ Q: Is the 5450B suitable for hazardous areas?
A: Yes, within its ATEX certification conditions. Suitability depends on the complete installation.
▶ Q: What distinguishes it from the 5450D?
A: The 5450B provides ATEX approval; the 5450D offers broader international certification coverage.

5450B1

5450B1

PR 5450B1 2-Wire Programmable Profibus PA Transmitters. Single Channel Input: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer 10 to 100kΩ. Output: Profibus PA. Accuracy ≤±0.05% of span. Response Time: <400ms. Power Supply 9-30vDC @ <352mW. 2.5kVAC Galvanic Isolation. Namur NE21, NE44, NE89 and NE107. Approvals: ATEX. Operating Temp: -40 to +85°C.

£510.00
Add to Basket More Info
5450B2

5450B2

PR 5450B2 2-Wire Programmable Profibus PA Transmitters. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer 10 to 100kΩ. Output: Profibus PA. Accuracy ≤±0.05% of span. Response Time: <400ms. Power Supply 9-30vDC @ <352mW. 2.5kVAC Galvanic Isolation. Namur NE21, NE44, NE89 and NE107. Approvals: ATEX. Operating Temp: -40 to +85°C.

£549.00
Add to Basket More Info
5909

5909

USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.

£240.00
Add to Basket More Info
8421

8421

DIN Rail mounting clip for head mount transmitters

£6.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000