The PR 5450B is an intrinsically safe, head-mounted PROFIBUS PA temperature transmitter for industrial measurement in hazardous areas. It accepts RTD, thermocouple, potentiometer, linear resistance and bipolar millivolt inputs, converting sensor signals into digital process data. Single or true dual-input options allow the transmitter to handle individual measurements, temperature comparisons and sensor redundancy within a compatible DIN form B sensor head.
The 5450B carries ATEX approval for specified hazardous gas and dust environments, including permitted installations in Zones 0, 1 and 2, Zones 21 and 22, and mining applications under its certification conditions.
Conformity with the FISCO concept supports its use in suitably designed intrinsically safe PROFIBUS PA networks. The transmitter, fieldbus supply, sensor connections and enclosure must be selected together to meet the requirements of the installation.
A broad choice of input types allows the 5450B to accommodate conventional temperature sensors and other supported electrical measurements. Sensor selection and measurement settings are configured to match the connected equipment.
For suitable RTDs, Callendar–Van Dusen coefficients allow the transmitter to use the characteristics of an individually calibrated sensor. Custom linearisation provides further flexibility for measurements requiring a defined relationship between the input and reported value.
True dual-input operation supports two compatible sensors connected to one transmitter. Available functions include individual measurements, averaging, differential measurement and minimum or maximum tracking.
Sensor redundancy supports measurement continuity, while drift detection monitors the difference between readings. An alert is generated when that difference exceeds a configured limit, helping maintenance teams identify and investigate a potential sensor issue.
The 5450B supports PROFIBUS PA Profile 4.0, transmitting measurement values and device status over the fieldbus connection. Power and communication share the two-wire bus.
Compatible configuration and asset-management software provides access to device parameters and diagnostics using the appropriate integration files. NAMUR NE107 diagnostic information helps the receiving system identify device conditions requiring attention.
The 5450B supports PROFIBUS PA Profile 4.0, transmitting measurement values and device status over the fieldbus connection. Power and communication share the two-wire bus.
Compatible configuration and asset-management software provides access to device parameters and diagnostics using the appropriate integration files. NAMUR NE107 diagnostic information helps the receiving system identify device conditions requiring attention.
| Type | Version | Inputs |
| 5450 | A: Zone 2 and zone 22 / Class I, Division 2, Groups A, B, C, D. B: Zone 0, 1, 2 and zone 21, 22 including M1. D: Zone 0, 1, 2 and zone 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D. | 1: Single Input (4 Terminals) 2: Dual Input (7 Terminals) |
Applications
Frequently Asked Questions
PR 5450B1 2-Wire Programmable Profibus PA Transmitters. Single Channel Input: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer 10 to 100kΩ. Output: Profibus PA. Accuracy ≤±0.05% of span. Response Time: <400ms. Power Supply 9-30vDC @ <352mW. 2.5kVAC Galvanic Isolation. Namur NE21, NE44, NE89 and NE107. Approvals: ATEX. Operating Temp: -40 to +85°C.
PR 5450B2 2-Wire Programmable Profibus PA Transmitters. True Dual Channel Inputs: -800 to 800mV or -0.1 to +1.7V; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 100kΩ or Potentiometer 10 to 100kΩ. Output: Profibus PA. Accuracy ≤±0.05% of span. Response Time: <400ms. Power Supply 9-30vDC @ <352mW. 2.5kVAC Galvanic Isolation. Namur NE21, NE44, NE89 and NE107. Approvals: ATEX. Operating Temp: -40 to +85°C.
USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.
A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.