he PR 5333D is an intrinsically safe, head-mounted 2-wire transmitter for RTD temperature and linear resistance measurements. It converts the selected sensor input into a standard 4–20 mA output for compatible monitoring and control equipment. Designed for DIN form B sensor heads, it provides three-wire lead-resistance compensation and programmable sensor error indication in a compact format.
The 5333D supports linearised temperature measurement with compatible platinum and nickel RTDs, including PT100 and PT1000 sensors. It can also convert linear resistance changes from suitable resistive sensors into a current signal.
Its dedicated RTD and resistance inputs suit applications where thermocouple or millivolt conversion is unnecessary. The sensor type and measurement range are configured to match the connected sensor and the requirements of the receiving equipment.
Resistance in sensor cables can influence an RTD measurement. The 5333D provides compensation for a three-wire connection, helping reduce this effect when the sensor and wiring meet the specified requirements.
The three-wire sensor connection is separate from the transmitter’s two-wire output loop. This allows an existing compatible three-wire probe to connect to a loop-powered monitoring system.
The same two wires supply transmitter power and carry the measurement output. The configured range is represented by the 4-20 mA signal, allowing connection to suitable PLC inputs, indicators, controllers and data acquisition systems.
Mounting the transmitter within the sensor head converts the resistance measurement close to its source, with the current signal carrying the result onwards to the receiving equipment.
The 5333D is programmed using PR Electronics PReset software and a compatible Loop Link interface. Configuration allows the transmitter to be matched to the sensor and required measurement range.
A programmable sensor error value provides a defined output response when a sensor fault is detected. The receiving system can use this response to identify a measurement problem and initiate an appropriate indication or alarm.
The 5333D is intended for hazardous-area use within its certification conditions. It must form part of a compatible intrinsically safe arrangement, including suitable associated equipment, sensor connections and enclosure.
When selecting the transmitter, check the sensor type, wiring arrangement, loop requirements and applicable approval conditions together. For applications requiring four-wire RTD measurement, consider the 5332D; for broader input capability, including thermocouples, consider the 5331D.
| Type | Version |
| 5333 | A: General Purpose, Zone 2, Div 2
D: Zone 0, 1, 2, 21, 22, M1/Div 1, Div 2 |
Applications
Frequently Asked Questions
PR 5333D 2-Wire Programmable Transmitters. Inputs: RTD (2 or 3 Wire) Range -200 to +850°C; Linear Resistance – 0 to 10,000Ω. Output: 4-20mA. Accuracy ≤±0.1% of span. Response Time: 0.33 to 60 Seconds. Power Supply 8-30vDC @ 0.7W Max. Namur NE43. Approvals: ATEX, IECEx & INMETRO; DNV & EAC EX Certification. Operating Temp: -40 to +85°C.
USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.