2000-NIT
AP-2000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 2000-NIT is designed for use with the AP-2000 Aquaprobe sensor with pH probe...
2000-TURB
AP-2000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale. Minimum Level of Detection 0.0 NTU, Minimum Level of Repeatibility 5.0 NTU...
5000-AMM
AP-5000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-5000 Aquaprobe sensor..
5000-CAL
AP-5000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 5000-CAL is designed for use with the AP-5000 Aquaprobe sensor with pH probe...
5000-CHL
AP-5000 Chloride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-19,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). The 5000-CHL is designed for use with the AP-5000 Aquaprobe sensor..
5000-FLU
AP-5000 Fluoride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 5000-FLU is designed for use with the AP-5000 Aquaprobe sensor with pH probe. Readings may be affected by Hydroxide ions...
5000-NIT
AP-5000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 5000-NIT is designed for use with the AP-5000 Aquaprobe sensor with pH probe...
5000-TURB
AP-5000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale. Minimum Level of Detection 0.0 NTU, Minimum Level of Repeatibility 5.0 NTU...
7000-AMM
AP-7000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-7000, or AP-6000, Aquaprobe sensor..
7000-CAL
AP-7000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 7000-CAL is designed for use with the AP-6000, or AP-7000, Aquaprobe sensor with pH probe...
7000-CHL
AP-7000 Chloride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-19,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). The 7000-CHL is designed for use with the AP-6000, or AP-7000, Aquaprobe sensor..
7000-CPHYLL
AP-7000 Chlorophyll Electrode with 2 Auto-Range scales 0-99.99 µg/L or 100-500 µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L...
7000-FLU
AP-7000 Fluoride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 7000-FLU is designed for use with the AP-7000, or AP-6000 Aquaprobe sensor with pH probe. Readings may be affected by..
7000-NIT
AP-7000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 7000-NIT is designed for use with the AP-6000, or AP-7000 Aquaprobe sensor with pH probe...
7000-TURB
AP-7000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale...
AMM-CAL
500ml Bottle of 1000 ppm Ammonium Stock Solution for Dilution...
AMM-CAL-10
500ml Bottle of 10 ppm Ammonium Solution for direct calibration...
AMM-CAL-100
500ml Bottle of 100 ppm Ammonium Solution for direct calibration or diluted in a 9:1 ratio with Deionised water to prepare a 10ppm solution...
AP-Lite Aquaprobe Package
The pocket sized Aquaprobe is designed to measure a single parameter, it consists of a small body with an optical electrode socket. Each sensor can be connected to any one of 8 of the optical electrodes available, which can be simply connected and disconnected as required. Available electrodes cover Turbidity,..
Aquatel Telemetry Leveline
Aquatel Telemeter Leveline is a Smart telemetry device designed for use with the Leveline range of water level probes. Constructed with carbon fiber and Aluminium, 2-year battery life (15 min logging and once a day upload. 4G modem communications. Leveline sensors used with this device can gain automatic compensation for..
CAL-CAL
500ml Bottle of 1000 ppm Calcium Stock Solution for Dilution...
CAL-CAL-10
500ml Bottle of 10 ppm Calcium Stock Solution for Direct Calibration...
CAL-CAL-100
500ml Bottle of 100 ppm Calcium Stock Solution for Direct Calibration or diluted in a 9:1 ratio with Deionised water to prepare a 10ppm solution...
CDOM-CAL-600
600ml bottle of CDOM calibration solution. (For point 2 CDOM calibration)...